A Fully Automated Visual Grading System for White Matter Hyperintensities of T2-Fluid Attenuated Inversion Recovery Magnetic Resonance Imaging

被引:4
|
作者
Rieu, ZunHyan [1 ]
Kim, Regina E. Y. [1 ]
Lee, Minho [1 ]
Kim, Hye Weon [1 ]
Kim, Donghyeon [1 ]
Yong, JeongHyun [1 ]
Kim, JiMin [2 ]
Lee, MinKyoung [3 ]
Lim, Hyunkook [4 ]
Kim, JeeYoung [2 ]
机构
[1] NEUROPHET Inc, Res Inst, Seoul 06234, South Korea
[2] Catholic Univ Korea, Eunpyeong St Marys Hosp, Coll Med, Dept Radiol, Seoul 06247, South Korea
[3] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Dept Radiol, Seoul 06247, South Korea
[4] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Dept Psychiat, Seoul 06247, South Korea
关键词
Fazekas scale; white matter lesion hyperintensity; T2-FLAIR; deep-learning; brain segmentation; EUCLIDEAN DISTANCE; ATROPHY; COEFFICIENTS; RELIABILITY;
D O I
10.31083/j.jin2203057
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The Fazekas scale is one of the most commonly used visual grading systems for white matter hyperintensity (WMH) for brain disorders like dementia from T2-fluid attenuated inversion recovery magnetic resonance (MR) images (T2-FLAIRs). However, the visual grading of the Fazekas scale suffers from low-intra and inter-rater reliability and high labor-intensive work. Therefore, we developed a fully automated visual grading system using quantifiable measurements. Methods: Our approach involves four stages: (1) the deep learning-based segmentation of ventricles and WMH lesions, (2) the categorization into periventricular white matter hyperintensity (PWMH) and deep white matter hyperintensity (DWMH), (3) the WMH diameter measurement, and (4) automated scoring, following the quantifiable method modified for Fazekas grading. We compared the performances of our method and that of the modified Fazekas scale graded by three neuroradiologists for 404 subjects with T2-FLAIR utilized from a clinical site in Korea. Results: The Krippendorff's alpha across our method and raters (A) versus those only between the radiologists (R) were comparable, showing substantial (0.694 vs. 0.732; 0.658 vs. 0.671) and moderate (0.579 vs. 0.586) level of agreements for the modified Fazekas, the DWMH, and the PWMH scales, respectively. Also, the average of areas under the receiver operating characteristic curve between the radiologists (0.80 & PLUSMN; 0.09) and the radiologists against our approach (0.80 & PLUSMN; 0.03) was comparable. Conclusions: Our fully automated visual grading system for WMH demonstrated comparable performance to the radiologists, which we believe has the potential to assist the radiologist in clinical findings with unbiased and consistent scoring.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Automatic segmentation and volumetric quantification of white matter hyperintensities on fluid-attenuated inversion recovery images using the extreme value distribution
    Wang, Rui
    Li, Chao
    Wang, Jie
    Wei, Xiaoer
    Li, Yuehua
    Zhu, Yuemin
    Zhang, Su
    NEURORADIOLOGY, 2015, 57 (03) : 307 - 320
  • [22] Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction
    Moioli, Melania
    Levionnois, Olivier
    Stein, Veronika M.
    Schupbach, Gertraud
    Schmidhalter, Marta
    Schweizer-Gorgas, Daniela
    FRONTIERS IN VETERINARY SCIENCE, 2017, 4
  • [23] Deep learning method for magnetic resonance imaging fluid-attenuated inversion recovery image synthesis
    Zhou J.
    Guo H.
    Chen H.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (05): : 903 - 911
  • [24] Subtle white matter intensity changes on fluid-attenuated inversion recovery imaging in patients with ischaemic stroke
    Cougo, Pedro
    Colares, Heber
    Farinhas, Joao Gabriel
    Haemmerle, Mariana
    Neves, Pedro
    Bezerra, Raquel
    Balduino, Alex
    Wu, Ona
    Pontes-Neto, Octavio M.
    BRAIN COMMUNICATIONS, 2024, 6 (02)
  • [25] Relationship between White Matter Hyperintensity Volume Analyzed from Fluid-Attenuated Inversion Recovery Using a Fully Automated Analysis Software and Cognitive Impairment
    Okawa, Ryuya
    Hayashi, Norio
    Takahashi, Tetsuhiko
    Yasui, Go
    Mihara, Ban
    DEMENTIA AND GERIATRIC COGNITIVE DISORDERS, 2025,
  • [26] T2-fluid attenuated inversion recovery fat-suppressed mismatch in the identification and characterization of lesions related to radiologically isolated syndrome
    Okuda, Darin T.
    Lebrun-Frenay, Christine
    BJR CASE REPORTS, 2024, 10 (04):
  • [27] Variability and validity of a simple visual rating scale in grading white matter changes on magnetic resonance imaging
    Fan, YH
    Lam, WWM
    Mok, VCT
    Huang, RX
    Wong, KS
    JOURNAL OF NEUROIMAGING, 2003, 13 (03) : 255 - 258
  • [28] T2-Weighted-Fluid-Attenuated Inversion Recovery Hyperintensity on Magnetic Resonance Imaging Is Associated With Aggressive Symptoms in Patients With Dural Arteriovenous Fistulas
    Patel, Bhuvic
    Chatterjee, Arindam
    Petr, Ondra
    Collins, Heather
    Lanzino, Giuseppe
    Derdeyn, Colin P.
    Zipfel, Gregory J.
    STROKE, 2019, 50 (09) : 2565 - 2567
  • [29] Comparing final ischemic stroke infarct volume using magnetic resonance imaging T2 and fluid attenuated inversion recovery (FLAIR) sequences
    McKean, D.
    Zavala, J. A.
    Teoh, H.
    Churilov, L.
    Ly, J.
    Wright, P.
    Phan, T.
    Davis, S. M.
    Donnan, G. A.
    Ma, H.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2009, 285 : S71 - S71
  • [30] Periventricular low intensities on fluid attenuated inversion recovery imaging in the newborn infant: Relationships to chronic white matter lesions
    Iwata, O
    Iwata, S
    Tamura, M
    Nakamura, T
    Hirabayashi, S
    Fueki, N
    Kondou, Y
    Kihara, H
    PEDIATRICS INTERNATIONAL, 2004, 46 (02) : 141 - 149