Simultaneous quantification of 3′,4′-dimethoxy flavonol-3-O-glucoside and its major metabolite in human plasma by LC-MS/MS and its application to a clinical pharmacokinetic study

被引:2
|
作者
Wang, Lu [1 ]
Shen, Haifeng [1 ]
Zhan, Yan [1 ]
Zhang, Yifan [1 ]
Zhang, Yong [2 ]
Chen, Min [2 ]
Li, Xiaoju [2 ]
Zhong, Dafang [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Mat Med, State Key Lab Drug Res, Shanghai 201203, Peoples R China
[2] Eight Plus One Pharmaceut Co Ltd, Guilin 541000, Peoples R China
基金
中国国家自然科学基金;
关键词
3?4?-Dimethoxy flavonol-3-O-glucoside; Aglycone glucuronide; LC-MS; MS; Human pharmacokinetic study; HYPERLIPIDEMIA; FLAVONOIDS; NARINGENIN; QUERCETIN; INSIGHTS;
D O I
10.1016/j.jpba.2022.115203
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hyperlipidemia is a disease characterized by abnormal blood lipid levels and is the leading risk factor for car-diovascular disease. 3 ',4 '-Dimethoxy flavonol-3-O-glucoside (abbreviated DF3G) is a new lipid-lowering drug created as a flavonoid structural analog. The principal metabolite of DF3G in human plasma is the aglycone glucuronide conjugate M2. The purpose of this study is to use liquid chromatography-tandem mass spectrometry to develop and validate a quantitative analysis method for DF3G and its metabolite M2 in human plasma, and to use the method to investigate the pharmacokinetics of DF3G and M2 in a clinical trial. This method employed DF3G-d6 as the internal standard, and plasma samples were processed by protein precipitation. Isocratic sepa-ration could accurately differentiate DF3G, M2, and DF3G-d6 from endogenous components in the matrix or other components in the samples, and endogenous components in the matrix had little impact on ionization efficiency. Positive electrospray ionization with multiple reaction monitoring (MRM) transitions of m/z 461.2-* 299.0 for DF3G, m/z 475.1-* 299.1 for M2 and m/z 467.1-* 305.1 for DF3G-d6 was used for quantification. The DF3G and M2 linear range for plasma were in the range of 4.00/4.00 ng/mL to 4000/4000 ng/mL. Both the analytes and the internal standard were stable regardless of whether they were in solution or plasma samples. The accuracy of the average concentration of the quality control samples was within 15% of the theoretical value, and the RSD was less than 15%. The method is rapid, accurate, straightforward, and precise. It is appropriate for the determination of DF3G and M2 concentrations in human plasma and has been successfully applied to determine the pharmacokinetic analysis in phase I clinical trials.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A sensitive LC-MS/MS method for simultaneous quantification of ulotaront and its N-desmethyl metabolite in human plasma and application to a clinical study
    Chen, Yu-Luan
    Shi, Yao
    LaFayette, Amber
    Shi, Lei
    Koblan, Kenneth S.
    Galluppi, Gerald R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 207
  • [22] Simultaneous Quantification of Mesalamine and Its Metabolite N-Acetyl Mesalamine in Human Plasma by LC-MS/MS and Its Application to a Bioequivalence Study
    Kanala, Kanchanamala
    Hwisa, Nagiat T.
    Chandu, Babu Rao
    Assaleh, Fathi H.
    Mukkanti, K.
    Katakam, Prakash
    Challa, Bala Sekhara Reddy
    BRITISH JOURNAL OF PHARMACEUTICAL RESEARCH, 2014, 4 (13): : 1568 - 1590
  • [23] Simultaneous determination of pioglitazone and candesartan in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Karra, Vijaya Kumari
    Pilli, Nageswara Rao
    Inamadugu, Jaswanth Kumar
    Rao, J. V. L. N. Seshagiri
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2012, 2 (03) : 167 - 173
  • [24] Simultaneous determination of atorvastatin and niacin in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Ravi, Vasu Babu
    Mullangi, Ramesh
    Inamadugu, Jaswanth Kumar
    Pilli, Nageswara Rao
    Gajula, Ramakrishna
    Ponneri, Venkateswarlu
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (11) : 1436 - 1443
  • [25] Simultaneous determination of telmisartan and amlodipine in human plasma by LC-MS/MS and its application in a human pharmacokinetic study
    Vasu Babu Ravi
    Jaswanth Kumar Inamadugu
    Nageswara Rao Pilli
    Vudagandla Sreenivasulu
    Venkateswarlu Ponneri
    Journal of Pharmaceutical Analysis, 2012, 2 (05) : 319 - 326
  • [26] Simultaneous determination of pioglitazone and candesartan in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Vijaya Kumari Karra
    Nageswara Rao Pilli
    Jaswanth Kumar Inamadugu
    J.V.L.N.Seshagiri Rao
    Journal of Pharmaceutical Analysis, 2012, 2 (03) : 167 - 173
  • [27] Simultaneous determination of sitagliptin and simvastatin in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Burugula, Laxminarayana
    Mullangi, Ramesh
    Pilli, Nageswara Rao
    Makula, Ajitha
    Lodagala, Durga Srinivas
    Kandhagatla, Rajnarayana
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) : 80 - 87
  • [28] Simultaneous determination of sibutramine and its active metabolites in human plasma by LC-MS/MS and its application to a pharmacokinetic study
    Bae, Jung-Woo
    Choi, Chang-Ik
    Jang, Choon-Gon
    Lee, Seok-Yong
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (11) : 1181 - 1188
  • [29] A sensitive LC-MS/MS method for the quantification of febuxostat in human plasma and its pharmacokinetic application
    Vaka, Venkata Rami Reddy
    Inamadugu, Jaswanth Kumar
    Pilli, Nageswara Rao
    Ramesh, Mullangi
    Katreddi, Hussain Reddy
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (11) : 1406 - 1412
  • [30] Simultaneous quantification of antofloxacin and its major metabolite in human urine by HPLC-MS/MS, and its application to a pharmacokinetic study
    Ma, Yunsu
    Wang, Qianru
    Zhang, Hongwen
    Xie, Lijun
    Chen, Juan
    Huang, Mao
    Liu, Yun
    Wang, Yuanyuan
    Wang, Libin
    Sun, Luning
    Ou, Ning
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (09)