Artificial intelligence for the detection of glaucoma with SD-OCT images: a systematic review and Meta-analysis

被引:3
|
作者
Shi, Nan-Nan [1 ,2 ]
Li, Jing [1 ,2 ]
Liu, Guang-Hui [1 ,2 ,3 ]
Cao, Ming-Fang [1 ,2 ,3 ]
机构
[1] Fujian Univ Tradit Chinese Med, Fujian Prov Peoples Hosp, Affiliated Peoples Hosp, Dept Ophthalmol, Fuzhou 350004, Fujian, Peoples R China
[2] Fujian Univ Tradit Chinese Med, Eye Inst Integrated Chinese & Western Med, Fuzhou 350004, Fujian, Peoples R China
[3] Fujian Univ Tradit Chinese Med, Affiliated Peoples Hosp, Fujian Prov Peoples Hosp, Dept Ophthalmol, 602 817,Middle Rd, Fuzhou 350004, Fujian, Peoples R China
关键词
artificial intelligence; spectral-domain optical coherence tomography; glaucoma; Meta-analysis; NERVE-FIBER LAYER; OPTICAL COHERENCE TOMOGRAPHY; CIRRUS HD; DIAGNOSIS;
D O I
10.18240/ijo.2024.03.02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To quantify the performance of artificial intelligence (AI) in detecting glaucoma with spectral-domain optical coherence tomography (SD-OCT) images. METHODS: Electronic databases including PubMed, Embase, Scopus, ScienceDirect, ProQuest and Cochrane Library were searched before May 31, 2023 which adopted AI for glaucoma detection with SD-OCT images. All pieces of the literature were screened and extracted by two investigators. Meta-analysis, Meta-regression, subgroup, and publication of bias were conducted by Stata16.0. The risk of bias assessment was performed in Revman5.4 using the QUADAS-2 tool. RESULTS: Twenty studies and 51 models were selected for systematic review and Meta-analysis. The pooled sensitivity and specificity were 0.91 (95%CI: 0.86-0.94, I-2=94.67%), 0.90 (95% CI: 0.87-0.92, I-2=89.24%). The pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 8.79 (95%CI: 6.93-11.15, I-2=89.31%) and 0.11 (95%CI: 0.07-0.16, I-2=95.25%). The pooled diagnostic odds ratio (DOR) and area under curve (AUC) were 83.58 (95%CI: 47.15-148.15, I-2=100%) and 0.95 (95%CI: 0.93-0.97). There was no threshold effect (Spearman correlation coefficient=0.22, P>0.05). CONCLUSION: There is a high accuracy for the detection of glaucoma with AI with SD-OCT images. The application of AI-based algorithms allows together with "doctor+artificial intelligence" to improve the diagnosis of glaucoma.
引用
收藏
页码:408 / 419
页数:12
相关论文
共 50 条
  • [21] Artificial Intelligence in Early Childhood Caries Detection and Prediction: A Systematic Review and Meta-Analysis
    Rokhshad, Rata
    Banakar, Morteza
    Shobeiri, Parnian
    Zhang, Ping
    PEDIATRIC DENTISTRY, 2024, 46 (06) : 385 - 394
  • [22] Application of artificial intelligence in diagnosis of osteoporosis using medical images: a systematic review and meta-analysis
    L. Gao
    T. Jiao
    Q. Feng
    W. Wang
    Osteoporosis International, 2021, 32 : 1279 - 1286
  • [23] Application of artificial intelligence in diagnosis of osteoporosis using medical images: a systematic review and meta-analysis
    Gao, L.
    Jiao, T.
    Feng, Q.
    Wang, W.
    OSTEOPOROSIS INTERNATIONAL, 2021, 32 (07) : 1279 - 1286
  • [24] Artificial Intelligence in Laryngeal Endoscopy: Systematic Review and Meta-Analysis
    Zurek, Michal
    Jasak, Kamil
    Niemczyk, Kazimierz
    Rzepakowska, Anna
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
  • [25] Performance of artificial intelligence using oral and maxillofacial CBCT images: A systematic review and meta-analysis
    Badr, F. F.
    Jadu, F. M.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (11) : 1918 - 1927
  • [26] Automated Choroidal Neovascularization Detection for Time Series SD-OCT Images
    Li, Yuchun
    Niu, Sijie
    Ji, Zexuan
    Fan, Wen
    Yuan, Songtao
    Chen, Qiang
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT II, 2018, 11071 : 381 - 388
  • [27] Deep learning algorithms for detection of diabetic macular edema in OCT images: A systematic review and meta-analysis
    Li, He-Yan
    Wang, Dai-Xi
    Dong, Li
    Wei, Wen-Bin
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 278 - 290
  • [28] Accuracy of artificial intelligence on histology prediction and detection of colorectal polyps: a systematic review and meta-analysis
    Lui, Thomas K. L.
    Guo, Chuan-Guo
    Leung, Wai K.
    GASTROINTESTINAL ENDOSCOPY, 2020, 92 (01) : 11 - +
  • [29] Artificial intelligence for classification and detection of oral mucosa lesions on photographs: a systematic review and meta-analysis
    Rokhshad, Rata
    Mohammad-Rahimi, Hossein
    Price, Jeffery B.
    Shoorgashti, Reyhaneh
    Abbasiparashkouh, Zahra
    Esmaeili, Mahdieh
    Sarfaraz, Bita
    Rokhshad, Arad
    Motamedian, Saeed Reza
    Soltani, Parisa
    Schwendicke, Falk
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (01)
  • [30] Artificial intelligence for classification and detection of oral mucosa lesions on photographs: a systematic review and meta-analysis
    Rata Rokhshad
    Hossein Mohammad-Rahimi
    Jeffery B. Price
    Reyhaneh Shoorgashti
    Zahra Abbasiparashkouh
    Mahdieh Esmaeili
    Bita Sarfaraz
    Arad Rokhshad
    Saeed Reza Motamedian
    Parisa Soltani
    Falk Schwendicke
    Clinical Oral Investigations, 28