LC-MS/MS methods for determination of venetoclax in human plasma and cerebrospinal fluid

被引:1
|
作者
Yang, Yan-Ling [1 ,2 ]
Qian, Zhou-Yi [1 ,2 ]
Zhao, Yang [1 ,2 ]
Chen, Xiang-Long [1 ]
Huang, Qiong-Ye [1 ,2 ]
Guo, Yu-Jiao [1 ]
Sun, Lu-Ning [1 ,2 ,3 ]
Wang, Yong-Qing [1 ,2 ,3 ]
机构
[1] Nanjing Med Univ, Res Div Clin Pharmacol, Affiliated Hosp 1, Nanjing, Peoples R China
[2] Nanjing Med Univ, Sch Pharm, Nanjing, Peoples R China
[3] Nanjing Med Univ, Res Div Clin Pharmacol, Affiliated Hosp 1, 300 Guangzhou Rd, Nanjing 210009, Peoples R China
关键词
cerebrospinal fluid; human plasma; MS/MS; venetoclax;
D O I
10.1002/bmc.5738
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed and validated sensitive MS/MS methods for the determination of venetoclax, an oral selective B-cell lymphoma-2 inhibitor, in human plasma and cerebrospinal fluid (CSF). Acetonitrile was used as protein precipitant. The mobile phase was 10 mM ammonium formate consisting of 0.1% formic acid and acetonitrile (40:60, v/v). The analytes were separated on an ACQUITY UPLC HSS T3 column (2.1 x 50 mm, 1.8 & mu;m) in 5 min. An API 4000 mass spectrometer was selected to quantify venetoclax and internal standard using m/z 868.3 & RARR; 636.3 and 876.3 & RARR; 644.3 under multiple response monitoring mode. In plasma, the calibration curve exhibited good linearity ranging from 20.0 to 5000 ng/mL, whereas in the CSF, the linear range was 0.500-100 ng/mL. The matrix effect of venetoclax and internal standard (venetoclax-d8) was not obvious in both plasma and CSF. The inter- and intra-run accuracy was within & PLUSMN;11.9%, and the inter- and intra-run precision was below 13.6%. Both methods had no carryover, and the recovery was close to 100%. The validated methods were employed to quantify the concentrations of venetoclax in the plasma and CSF of patients diagnosed with chronic lymphocytic leukemia or acute myelogenous leukemia.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Quantification of hepcidin-25 in human cerebrospinal fluid using LC-MS/MS
    Delaby, Constance
    Bros, Pauline
    Vialaret, Jerome
    Moulinier, Amandine
    Delatour, Vincent
    Gabelle, Audrey
    Lehmann, Sylvain
    Hirtz, Christophe
    BIOANALYSIS, 2017, 9 (04) : 337 - 347
  • [42] Determination of Fenofibric Acid in Human Plasma by LC-MS/MS and LC-UV
    Arafat, Tawfiq
    Arafat, Basil
    Abu Awwad, Ahmad
    Schmitz, Oliver J.
    CHROMATOGRAPHIA, 2016, 79 (11-12) : 685 - 692
  • [43] A validated LC-MS/MS assay for quantification of 24(S)-hydroxycholesterol in plasma and cerebrospinal fluid
    Sidhu, Rohini
    Jiang, Hui
    Farhat, Nicole Y.
    Carrillo-Carrasco, Nuria
    Woolery, Myra
    Ottinger, Elizabeth
    Porter, Forbes D.
    Schaffer, Jean E.
    Ory, Daniel S.
    Jiang, Xuntian
    JOURNAL OF LIPID RESEARCH, 2015, 56 (06) : 1222 - 1233
  • [44] Quantitative determination of octylonium in human plasma by LC-MS
    Kim, Kibum
    Jung, Haehum
    Yun, Hyi-Yoel
    Moon, Seung-Ok
    Yoon, Young-Ran
    Kwon, Kwang-il
    Kim, Hyesoo
    Shon, Soojung
    Kang, Wonku
    CHROMATOGRAPHIA, 2007, 66 (3-4) : 257 - 260
  • [45] Determination of Meropenem in Rabbit Plasma by LC-MS/MS
    Lin, Guanyang
    Zhang, Haiyan
    Xue, Feng
    Li, Wenjuan
    Liu, Naihua
    Chen, Lianguo
    Wang, Xianqin
    Xu, Renai
    Ma, Jianshe
    LATIN AMERICAN JOURNAL OF PHARMACY, 2011, 30 (10): : 1895 - 1900
  • [46] Determination of Diclofenac Potassium in Human Plasma by LC-MS
    Praksah, T. Bhanu
    Sri, K. Vijaya
    Krishna, S. Rama
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (06) : 4183 - 4189
  • [47] LC-MS determination of gabapentin from human plasma
    Oiha, Ashwini
    Rathod, Raieshwari
    Patel, Chaula
    Padh, Harish
    CHROMATOGRAPHIA, 2007, 66 (11-12) : 853 - 857
  • [48] Determination of Clenbuterol in Various Edible Parts of Livestock Products by LC-MS/MS and LC-MS/MS/MS Methods
    HAYASHI, Takako
    HAMASE, Kenji
    CHROMATOGRAPHY, 2021, 42 (01) : 43 - 48
  • [49] Validation of LC-MS/MS methods for the determination of mirabegron and eight metabolites in human plasma in a paediatric population
    Meijer, John
    van den Berg, Tom
    Huls, Robert
    Hofstede, Vincent
    Niesing, Willem
    van den Beld, Cas
    Krauwinkel, Walter
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 167 : 155 - 160
  • [50] Sensitive LC-MS/MS Methods for Amphotericin B Analysis in Cerebrospinal Fluid, Plasma, Plasma Ultrafiltrate, and Urine: Application to Clinical Pharmacokinetics
    Pippa, Leandro Francisco
    Marques, Maria Paula
    Silva, Anna Christina Tojal da
    Vilar, Fernando Crivelenti
    de Haes, Tissiana Marques
    Fonseca, Benedito Antonio Lopes da
    Martinez, Roberto
    Coelho, Eduardo Barbosa
    Wichert-Ana, Lauro
    Lanchote, Vera Lucia
    FRONTIERS IN CHEMISTRY, 2021, 9