Psychometric properties of a standardized protocol of muscle strength assessment by hand-held dynamometry in healthy adults: a reliability study

被引:10
|
作者
Morin, Marika [1 ]
Hebert, Luc J. [2 ,3 ,4 ,5 ]
Perron, Marc [2 ,3 ]
Petitclerc, Emilie [5 ]
Lake, Shanna-Rose [5 ]
Duchesne, Elise [1 ,4 ,6 ,7 ]
机构
[1] Univ Quebec Chicoutimi, Dept Hlth Sci, 555 Bd Univ, Chicoutimi, PQ G7H 2B1, Canada
[2] Univ Laval, Fac Med, Dept Rehabil, Quebec City, PQ, Canada
[3] Univ Laval, Fac Med, Dept Radiol & Nucl Med, Quebec City, PQ, Canada
[4] Integrated Univ Ctr Hlth & Social Serv Saguenay L, Interdisciplinary Res Grp Neuromuscular Dis GRIMN, Jonquiere, PQ, Canada
[5] Integrated Univ Ctr Hlth & Social Serv Capitale N, Interdisciplinary Res Ctr Rehabil & Social Integr, Quebec City, PQ, Canada
[6] Univ Quebec Chicoutimi, Intersectoral Ctr Sustainable Hlth, Chicoutimi, PQ, Canada
[7] Res Ctr Charles Le Moyne CRCLM, Sherbrooke, PQ, Canada
关键词
Hand-held dynamometry; Muscle strength; Psychometric properties; Quantitative evaluation; Reliability; Standard error of measurement; Minimal detectable change; ISOKINETIC DYNAMOMETRY; KNEE; VALIDITY; BELT; HIP;
D O I
10.1186/s12891-023-06400-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundMaximal isometric muscle strength (MIMS) assessment is a key component of physiotherapists' work. Hand-held dynamometry (HHD) is a simple and quick method to obtain quantified MIMS values that have been shown to be valid, reliable, and more responsive than manual muscle testing. However, the lack of MIMS reference values for several muscle groups in healthy adults with well-known psychometric properties limits the use and the interpretation of these measures obtained with HHD in clinic.ObjectiveTo determine the intra- and inter-rater reliability, standard error of measurement (SEM) and minimal detectable change (MDC) of MIMS torque values obtained with HHD.MethodsIntra and Inter-rater Reliability Study. The MIMS torque of 17 muscle groups was assessed by two independent raters at three different times in 30 healthy adults using a standardized HHD protocol using the MEDup (TM) (Atlas Medic, Quebec, Canada). Participants were excluded if they presented any of the following criteria: 1) participation in sport at a competitive level; 2) degenerative or neuromusculoskeletal disease that could affect torque measurements; 3) traumatic experience or disease in the previous years that could affect their muscle function; and 4) use of medication that could impact muscle strength (e.g., muscle relaxants, analgesics, opioids) at the time of the evaluation. Intra- and inter-rater reliability were determined using two-way mixed (intra) and random effects (inter) absolute agreement intraclass correlation coefficients (ICC: 95% confidence interval) models. SEM and MDC were calculated from these data.ResultsIntra- and inter-rater reliability were excellent with ICC (95% confidence interval) varying from 0.90 to 0.99 (0.85-0.99) and 0.89 to 0.99 (0.55-0.995), respectively. Absolute SEM and MDC for intra-rater reliability ranged from 0.14 to 3.20 Nm and 0.38 to 8.87 Nm, respectively, and from 0.17 to 5.80 Nm and 0.47 to 16.06 Nm for inter-rater reliability, respectively.ConclusionsThe excellent reliability obtained in this study suggest that the use of such a standardized HHD protocol is a method of choice for MIMS torque measurements in both clinical and research settings. And the identification of the now known metrological qualities of such a protocol should encourage and promote the optimal use of manual dynamometry.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years
    Bohannon, RW
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (01): : 26 - 32
  • [32] Maximum isometric muscle force obtained by hand-held dynamometry in a healthy and eutrophic pediatric population
    Escobar, R. G.
    Munoz, K.
    Banados, P.
    Robles, A.
    NEUROMUSCULAR DISORDERS, 2011, 21 (9-10) : 653 - 653
  • [33] RELIABILITY OF HAND-HELD DYNAMOMETRY AND ITS RELATIONSHIP WITH MANUAL MUSCLE TESTING IN PATIENTS WITH OSTEOARTHRITIS IN THE KNEE
    HAYES, KW
    FALCONER, J
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (03): : 145 - 149
  • [34] MUSCLE STRENGTH EVALUATED USING THE HAND-HELD DYNAMOMETER MICROFET2 IN OLDER ADULTS: A RELIABILITY STUDY
    Locquet, M.
    Beaudart, C.
    Reginster, J. -Y.
    Bruyere, O.
    Croisier, J. -L.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (SUPPL 1) : S301 - S302
  • [35] Literature reporting normative data for muscle strength measured by hand-held dynamometry: A systematic review
    Bohannon, Richard W.
    ISOKINETICS AND EXERCISE SCIENCE, 2011, 19 (03) : 143 - 147
  • [36] Responsiveness of hand-held dynamometry to changes in limb muscle strength: A retrospective investigation of published research
    Bohannon, Richard W.
    ISOKINETICS AND EXERCISE SCIENCE, 2009, 17 (04) : 221 - 225
  • [37] Lower Extremity Strength Profile in Ambulatory Adults with Cerebral Palsy and Spastic Diplegia: Norm Values and Reliability for Hand-Held Dynamometry
    Eken, Maaike M.
    Lamberts, Robert P.
    Koschnick, Susanne
    Du Toit, Jacques
    Veerbeek, Berendina E.
    Langerak, Nelleke G.
    PM&R, 2020, 12 (06) : 573 - 580
  • [38] Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke
    Mentiplay, Benjamin F.
    Tan, Dawn
    Williams, Gavin
    Adair, Brooke
    Pua, Yong-Hao
    Bower, Kelly J.
    Clark, Ross A.
    JOURNAL OF BIOMECHANICS, 2018, 75 : 171 - 175
  • [39] Absolute Reliability and Concurrent Validity of Hand-Held Dynamometry in Shoulder Rotator Strength Assessment: Systematic Review and Meta-Analysis
    Chamorro, Claudio
    Arancibia, Miguel
    Trigo, Benjamin
    Arias-Poblete, Leonidas
    Jerez-Mayorga, Daniel
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (17)
  • [40] INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY - EFFECTS OF RATER GENDER, BODY-WEIGHT, AND GRIP STRENGTH
    WADSWORTH, CT
    NIELSEN, DH
    CORCORAN, DS
    PHILLIPS, CE
    SANNES, TL