Standardized 2D atrial mapping and its clinical applications

被引:2
|
作者
Wang, Tiantian [1 ]
Karel, Joel [1 ]
Invers-Rubio, Eric [3 ]
Hernandez-Romero, Ismael [2 ]
Peeters, Ralf [1 ]
Bonizzi, Pietro [1 ]
Guillem, Maria S. [2 ]
机构
[1] Maastricht Univ, Dept Adv Comp Sci, Maastricht, Netherlands
[2] Univ Politecn Valencia, ITACA Inst, Valencia, Spain
[3] Univ Barcelona, Hosp Clin Barcelona Cardiovasc Inst ICCV, Arrhythmia Unit, Barcelona, Catalonia, Spain
关键词
2D atrial mapping; Atrial fibrillation; ECG-imaging; MAGNETIC-RESONANCE; DOMINANT FREQUENCY; FIBRILLATION; HEART;
D O I
10.1016/j.compbiomed.2023.107755
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The visualization and comparison of electrophysiological information in the atrium among different patients could be facilitated by a standardized 2D atrial mapping. However, due to the complexity of the atrial anatomy, unfolding the 3D geometry into a 2D atrial mapping is challenging. In this study, we aim to develop a standardized approach to achieve a 2D atrial mapping that connects the left and right atria, while maintaining fixed positions and sizes of atrial segments across individuals. Atrial segmentation is a prerequisite for the process. Segmentation includes 19 different segments with 12 segments from the left atrium, 5 segments from the right atrium, and two segments for the atrial septum. To ensure consistent and physiologically meaningful segment connections, an automated procedure is applied to open up the atrial surfaces and project the 3D information into 2D. The corresponding 2D atrial mapping can then be utilized to visualize different electrophysiological information of a patient, such as activation time patterns or phase maps. This can in turn provide useful information for guiding catheter ablation. The proposed standardized 2D maps can also be used to compare more easily structural information like fibrosis distribution with rotor presence and location. We show several examples of visualization of different electrophysiological properties for both healthy subjects and patients affected by atrial fibrillation. These examples show that the proposed maps provide an easy way to visualize and interpret intra-subject information and perform inter-subject comparison, which may provide a reference framework for the analysis of the atrial fibrillation substrate before treatment, and during a catheter ablation procedure.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Introduction to 2D materials and their applications
    Berman, Diana
    Jastrzebska, Agnieszka
    Papi, Massimiliano
    Rosenkranz, Andreas
    RSC ADVANCES, 2024, 14 (24) : 17234 - 17235
  • [22] Synthesis and properties of graphene and its 2D inorganic analogues with potential applications
    Gupta, Uttam
    Gopalakrishnan, K.
    Rao, C. N. R.
    BULLETIN OF MATERIALS SCIENCE, 2018, 41 (05)
  • [23] The meshless virtual boundary method and its applications to 2D elasticity problems
    Sun Haitao
    Wang Yuanhan
    ACTA MECHANICA SOLIDA SINICA, 2007, 20 (01) : 30 - 40
  • [24] Synthesis and properties of graphene and its 2D inorganic analogues with potential applications
    Uttam Gupta
    K Gopalakrishnan
    C N R Rao
    Bulletin of Materials Science, 2018, 41
  • [25] THE MESHLESS VIRTUAL BOUNDARY METHOD AND ITS APPLICATIONS TO 2D ELASTICITY PROBLEMS
    Sun Haitao Wang Yuanhan (School of Civil Engineering and Mechanics
    Acta Mechanica Solida Sinica, 2007, (01) : 30 - 40
  • [26] The meshless virtual boundary method and its applications to 2D elasticity problems
    Haitao Sun
    Yuanhan Wang
    Acta Mechanica Solida Sinica, 2007, 20 : 30 - 40
  • [27] Separable 2D dyadic wavelet and its applications in contour detection of handwriting
    Sun, Yan-Kui
    Huang, Wan
    2007 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, VOLS 1-4, PROCEEDINGS, 2007, : 1316 - 1321
  • [28] 2D Multisine Mapping for Robust 2 Band PA Modeling and 2D Predistorter Extraction
    Roblin, Patrick
    Naraharisetti, Naveen
    Quindroit, Christophe
    Gheitanchi, Shahin
    Mauer, Volker
    Fitton, Mike
    2013 81ST ARFTG MICROWAVE MEASUREMENT CONFERENCE (ARFTG), 2013,
  • [29] 2D or not 2D? Mapping the in-depth inclination of the collagen fibers of the corneoscleral shell
    Ji, Fengting
    Quinn, Marissa
    Hua, Yi
    Lee, Po-Yi
    Sigal, Ian A.
    EXPERIMENTAL EYE RESEARCH, 2023, 237
  • [30] Advances in 2D/2D Z-Scheme Heterojunctions for Photocatalytic Applications
    Liu, Xiaolei
    Zhang, Qingzhe
    Ma, Dongling
    SOLAR RRL, 2021, 5 (02)