Towards the automated detection of interictal epileptiform discharges with magnetoencephalography

被引:2
|
作者
Fernandez-Martin, Raquel [1 ,6 ]
Feys, Odile [1 ,2 ]
Juvene, Elodie [3 ]
Aeby, Alec [3 ]
Urbain, Charline [1 ,4 ]
De Tiege, Xavier [1 ,5 ]
Wens, Vincent [1 ,5 ]
机构
[1] Univ Libre Bruxelles ULB, ULB Neurosci Inst UNI, Lab Neuroanat & Neuroimagerie Translat LN2T, Brussels, Belgium
[2] Univ libre Bruxelles ULB, Hop Univ Bruxelles HUB, Hop Erasme, Dept Neurol, Brussels, Belgium
[3] Univ Libre Bruxelles ULB, Hop Univ Bruxelles HUB, Dept Radiat Oncol, B-1070 Brussels, Belgium
[4] Univ Libre Bruxelles ULB, Ctr Res Cognit & Neurosci CRCN, Neuropsychol & Funct Neuroimaging Res Unit UR2NF, UNI ULB Neurosci Inst, Brussels, Belgium
[5] Univ Libre Bruxelles ULB, Hop Univ Bruxelles HUB, Hop Erasme, Dept Translat Neuroimaging, Brussels, Belgium
[6] HUB Hop Erasme, Dept Translat Neuroimaging, 808 Route Lennik, B-1070 Brussels, Belgium
关键词
Interictal epileptiform; Epilepsy; Automated detection; Magnetoencephalography; Hidden Markov Modeling; Independent Components Analysis; EPILEPTOGENIC ZONE; MEG; EPILEPSY; LOCALIZATION; EEG; NETWORKS; ILAE;
D O I
10.1016/j.jneumeth.2023.110052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: The analysis of clinical magnetoencephalography (MEG) in patients with epilepsy traditionally relies on visual identification of interictal epileptiform discharges (IEDs), which is time consuming and dependent on subjective criteria. New Method: Here, we explore the ability of Independent Components Analysis (ICA) and Hidden Markov Modeling (HMM) to automatically detect and localize IEDs. We tested our pipelines on resting-state MEG recordings from 10 school-aged children with (multi)focal epilepsy. Results: In focal epilepsy patients, both pipelines successfully detected visually identified IEDs, but also revealed unidentified low-amplitude IEDs. Success was more mitigated in patients with multifocal epilepsy, as our automated pipeline missed IED activity associated with some foci-an issue that could be alleviated by post-hoc manual selection of epileptiform ICs or HMM states. Comparison with existing methods: We compared our results with visual IED detection by an experienced clinical magnetoencephalographer, getting heightened sensitivity and requiring minimal input from clinical practitioners. Conclusions: IED detection based on ICA or HMM represents an efficient way to identify IED localization and timing. The development of these automatic IED detection algorithms provide a step forward in clinical MEG practice by decreasing the duration of MEG analysis and enhancing its sensitivity.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [31] Preoperative simulation of intracerebral epileptiform discharges: synthetic aperture magnetometry virtual sensor analysis of interictal magnetoencephalography data
    Oishi, Makoto
    Otsubo, Hiroshi
    Iida, Koji
    Suyama, Yasuhiro
    Ochi, Ayako
    Weiss, Shelly K.
    Xiang, Jing
    Gaetz, William
    Cheyne, Douglas
    Chuang, Sylvester H.
    Rutka, James T.
    Snead, O. Carter, III
    JOURNAL OF NEUROSURGERY, 2006, 105 (01) : 41 - 49
  • [32] Significance of interictal occipital epileptiform discharges in children
    Wang, Chunyang
    Khurana, Divya S.
    Kothare, Sanjeev V.
    Legido, Agustin
    Harrison, Geoffrey
    Carvalho, Karen S.
    Valencia, Ignacio
    EPILEPTIC DISORDERS, 2010, 12 (01) : 59 - 64
  • [33] Quantitative analysis of interictal epileptiform discharges in autism
    Lyons, LD
    Rust, RS
    Quigg, M
    EPILEPSIA, 2005, 46 : 78 - 78
  • [34] Mutual information analysis and detection of interictal morphological differences in interictal epileptiform discharges of patients with partial epilepsies
    Varma, NK
    Kushwaha, R
    Beydoun, A
    Williams, WJ
    Drury, I
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 103 (04): : 426 - 433
  • [35] Detection of Intracranial Signatures of Interictal Epileptiform Discharges from Concurrent Scalp EEG
    Spyrou, Loukianos
    Martin-Lopez, David
    Valentin, Antonio
    Alarcon, Gonzalo
    Sanei, Saeid
    INTERNATIONAL JOURNAL OF NEURAL SYSTEMS, 2016, 26 (04)
  • [36] Sensor selection and miniaturization limits for detection of interictal epileptiform discharges with wearable EEG
    Dan, Jonathan
    Foged, Mette Thrane
    Vandendriessche, Benjamin
    Van Paesschen, Wim
    Bertrand, Alexander
    JOURNAL OF NEURAL ENGINEERING, 2023, 20 (01)
  • [37] FOCAL EPILEPTIFORM DISCHARGES DETECTED BY MAGNETOENCEPHALOGRAPHY AND SIMULTANEOUS ELECTROENCEPHALOGRAPHY
    Duez, L.
    Tankisi, H.
    Sidenius, P.
    Sabers, A.
    Pinborg, L.
    Fabricius, M.
    Rubboli, G.
    Pedersen, B.
    Leffers, A-M.
    Uldall, P.
    Brennum, J.
    Fuglsang-Frederiksena, A.
    Beniczkya, S.
    EPILEPSIA, 2017, 58 : S9 - S9
  • [38] AUTOMATED-ANALYSIS OF SURFACE AND INTRACELLULAR-POTENTIALS DURING INTERICTAL AND ICTAL EPILEPTIFORM DISCHARGES
    AVOLI, M
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 50 (3-4): : P76 - P77
  • [39] The Role of Interictal Epileptiform Discharges in Epilepsy Surgery Outcome
    Habibabadi, Jafar Mehvari
    Zare, Mohamad
    Tabrizi, Nasim
    INTERNATIONAL JOURNAL OF PREVENTIVE MEDICINE, 2019, 10
  • [40] Effect of sleep stages on bitemporal interictal epileptiform discharges
    Belyakova-Bodina, Alexandra
    Abramova, Anna
    Dolgova, Snezhana
    Broutian, Amayak
    EPILEPSIA, 2021, 62 : 128 - 129