Durability of Resin Bonding to Dental 3Y-TZP Zirconia Using Different Adhesive Systems

被引:1
|
作者
Yazigi, Christine [1 ]
Alawi, Shila [1 ]
Wille, Sebastian [1 ]
Lehmann, Frank [1 ]
Kern, Matthias [1 ]
机构
[1] Christian Albrechts Univ Kiel, Sch Dent, Dept Prosthodont Propaedeut & Dent Mat, D-24105 Kiel, Germany
关键词
adhesive bonding; luting resins; MDP; primer; zirconia ceramic; self-adhesive luting resin; conventional luting resin; PREPARATION DESIGNS; CERAMIC INLAYS; STRENGTH; CEMENTS; COMPOSITE; RESTORATIONS; TOOTH; SHEAR; SURVIVAL; PRIMERS;
D O I
10.3390/ma17020424
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This laboratory study was conducted to evaluate and compare the resin bond strength of different adhesive resin systems in different combinations and the durability of their bonds with zirconia ceramic. Materials and methods: One hundred and twenty-eight specimens were milled from 3Y-TZP zirconia ceramic. The bonding surfaces of all disks were wet polished, steam cleaned, airborne-particle abraded and ultrasonically cleaned in 99% isopropanol. The specimens were randomly divided into four main groups according to the applied resin system; two conventional and two self-adhesive systems were used. Each group was further subdivided into two subgroups; the first was conditioned with the specified primer for conventional luting resins or not conditioned for the self-adhesive systems, whereas the second subgroup of each was conditioned with the same phosphate monomer-containing primer (Alloy Primer). The zirconia specimens were adhesively bonded, using the allocated luting resin, to plexiglass tubes filled with self-curing composite resin (Clearfil FII). Half of the specimens of each subgroup were stored in distilled water at 37 degrees C for 3 days, whereas the other half were subjected to artificial aging, 150 days of storage and additional thermal cycling. Thereafter, all specimens were subjected to TBS testing using a universal testing machine. Statistical analysis was conducted using two-way ANOVA followed by separate one-way ANOVAs. The Games-Howell post-hoc test was applied for pairwise comparisons. Results: All specimens survived storage with thermal cycling. The mean TBS values ranged from a minimum of 43.4 +/- 5.0 MPa to a maximum of 66.4 +/- 3.5 after 3 days and from a minimum of 13.6 +/- 2.5 MPa to a maximum of 50.1 +/- 9.4 MPa after 150 days. Conclusions: Artificial aging had a significantly negative effect on all test groups. The chosen adhesive-resin system had a significant effect on the resulting TBS values. The highest TBS values were achieved for the self-adhesive luting resin G-Cem One but were statistically comparable to the results obtained for the dual-cure luting resin G-Cem LinkForce.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Aging of 3Y-TZP dental zirconia and yttrium depletion
    Pandoleon, P.
    Kontonasaki, E.
    Kantiranis, N.
    Pliatsikas, N.
    Patsalas, P.
    Papadopoulou, L.
    Zorba, T.
    Paraskevopoulos, K. M.
    Koidis, P.
    DENTAL MATERIALS, 2017, 33 (11) : E385 - E392
  • [2] PRESSURELESS BONDING OF 3Y-TZP TO TITANIUM
    KOGURE, E
    HOSHINO, H
    IIDA, T
    MITAMURA, T
    NIPPON SERAMIKKUSU KYOKAI GAKUJUTSU RONBUNSHI-JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1988, 96 (11): : 1057 - 1065
  • [3] Influence of Cleaning Methods on Resin Bonding to Contaminated Translucent 3Y-TZP ceramic
    Al-Dobaei, Eglal
    Al-Akhali, Majed
    Polonskyi, Oleksandr
    Strunskus, Thomas
    Wille, Sebastian
    Kern, Matthias
    JOURNAL OF ADHESIVE DENTISTRY, 2020, 22 (04): : 383 - 391
  • [4] Durability of Resin Bonding to Zirconia Ceramic Using Different Primers
    Lehmann, Frank
    Kern, Matthias
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (06): : 479 - 483
  • [5] PRESSURELESS BONDING OF 3Y-TZP AND FE USING TI SHEET
    KOGURE, E
    HOSHINO, H
    IIDA, T
    MITAMURA, T
    NIPPON SERAMIKKUSU KYOKAI GAKUJUTSU RONBUNSHI-JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1988, 96 (12): : 1142 - 1148
  • [6] In vivo aging of zirconia dental ceramics - Part I: Biomedical grade 3Y-TZP
    Kocjan, Andraz
    Cotic, Jasna
    Kosmac, Tomaz
    Jevnikar, Peter
    DENTAL MATERIALS, 2021, 37 (03) : 443 - 453
  • [7] Cavitation damage mechanisms in a superplastic zirconia(3Y-TZP)
    Hiraga, K
    Nakano, K
    SUPERPLASTICITY IN ADVANCED MATERIALS - ICSAM-97, 1997, 243-2 : 387 - 392
  • [8] Reliability and lifetime of lithium disilicate, 3Y-TZP, and 5Y-TZP zirconia crowns with different occlusal thicknesses
    Gelson Luis Adabo
    Diogo Longhini
    Mariana Ribeiro Baldochi
    Edmara Tatiely Pedroso Bergamo
    Estevam Augusto Bonfante
    Clinical Oral Investigations, 2023, 27 : 3827 - 3838
  • [9] Reliability and lifetime of lithium disilicate, 3Y-TZP, and 5Y-TZP zirconia crowns with different occlusal thicknesses
    Adabo, Gelson Luis
    Longhini, Diogo
    Baldochi, Mariana Ribeiro
    Bergamo, Edmara Tatiely Pedroso
    Bonfante, Estevam Augusto
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (07) : 3827 - 3838
  • [10] Space Charge and Grain Boundary Energy in Zirconia (3Y-TZP)
    Conrad, Hans
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2011, 94 (11) : 3641 - 3642