Adaptive positioning current measurement method for multi-conductor system based on linear magnetic sensor array

被引:4
|
作者
Fan, Haoyang [1 ]
Zhang, Zhenyuan [1 ]
Huang, Qi [2 ]
Liao, Kaiji [3 ]
Jing, Shi [1 ]
机构
[1] Univ Elect Sci & Technol China, Xiyuan Ave 2006, Chengdu 610000, Peoples R China
[2] Chengdu Univ Technol, East Third Rd 1, Chengdu 610000, Peoples R China
[3] State Grid Sichuan Elect Power Corp Metering Ctr, Wanjing Rd 1, Chengdu 610000, Peoples R China
关键词
Non -contact measurement; Current positioning; Kalman Filter; Crosstalk rejection; Magnetic sensor array; INTERFERENCE; CONTACTLESS; SAG;
D O I
10.1016/j.ijepes.2022.108692
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As transmission and distribution networks now span a wider region, the difficulty of monitoring lines and the incidence of faults are both increased, which reduces the stability of the power system. During the troubleshooting procedure, quick problem identification, line selection, and placement are essential, and non-contact current measurement can be quite helpful. Its advantages include the capacity to monitor high-frequency current and line space position, both of which contain a range of fault characteristics, as well as a high-frequency band, compact size, low cost, and simple installation. In this paper, we present an adaptive positioning current measurement method for multi-conductor systems based on a linear magnetic sensor array. The method detects the position shifts of individual conductors when their locations are displaced to varying degrees using a novel conductor positioning calculation algorithm. Besides, it automatically adjusts the measurement matrix to provide precise current measurements. In the simulations, three-phase parallel currents with an amplitude of 100 A are analyzed based on the parameters of a 15-meter cup-type tensile tower. During the different displacements of the three conductors, the new method calculates the conductor displacements and the current in real-time. For all the three conductor positions change with the maximum amplitude of 2 m, the average error of all the conductor position measurements is about 0.1 m, and the root mean square error (RMSE) of the currents drops from 34.18A to 3.72A with correction, which proves the effectiveness of the algorithm.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Study of Current Measurement Method Based on Circular Magnetic Field Sensing Array
    Li, Zhenhua
    Zhang, Siqiu
    Wu, Zhengtian
    Abu-Siada, Ahmed
    Tao, Yuan
    SENSORS, 2018, 18 (05)
  • [22] Precise Positioning Based on Pixel Differential in Linear Optical Sensor Array
    Alsayed, Abdallah
    Mahadi, Muhammad Razif
    2ND INTERNATIONAL CONFERENCE ON AGRICULTURAL AND FOOD ENGINEERING (CAFE 2014) - NEW TRENDS FORWARD, 2014, 2 : 10 - 17
  • [23] A Novel Non-contact Measurement Method for Current Positioning Based on Magnetic Sensors
    Fan, Haoyang
    Huang, Qi
    Zhang, Zhenyuan
    Jing, Shi
    Liao, Kaiji
    Yang, Xin
    2021 IEEE IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (IEEE I&CPS ASIA 2021), 2021, : 1518 - 1524
  • [24] A Novel method for current measurement in an off-centered conductor of a circular array current probe
    Veeranjaneyulu, Mallela
    Srungavarapu, Gopalakrishna
    MEASUREMENT, 2024, 233
  • [25] Visible Light Positioning System Based on Photodiode Array Sensor
    Ru, Gui
    Qin, Ling
    Wang, Fengying
    Hu, Xiaoli
    Zhao, Desheng
    ACTA OPTICA SINICA, 2024, 44 (21)
  • [26] Circular Array of Magnetic Sensors for Current Measurement: Analysis for Error Caused by Position of Conductor
    Yu, Hao
    Qian, Zheng
    Liu, Huayi
    Qu, Jiaqi
    SENSORS, 2018, 18 (02)
  • [27] Surface Wave Based Non-conductor-contact Reflectometry Method for Insulation and Jacket Damage Detection in Multi-Conductor Cables
    Arman, Ahmed S.
    Glass, Samuel W., III
    Fifield, Leonard S.
    Ali, Mohammod
    2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 431 - 434
  • [28] Magnetic Sensor-Based Switching Cabinet Busbar Current Measurement Method
    Li, Wenyun
    Tan, Xiangyu
    Ao, Gang
    Xu, Xiaowei
    Zhang, Wenbin
    Cheng, Kang
    INTEGRATED FERROELECTRICS, 2023, 235 (01) : 81 - 92
  • [29] Research on Grounding Grid Conductor Positioning Based on PCB Coil Magnetic Field Sensor
    Chen Chao
    Wu Di
    Pan Bailang
    Xu Ke
    Han Shen
    Hu Jiayuan
    2020 5TH INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL CONTROL TECHNOLOGY AND TRANSPORTATION (ICECTT 2020), 2020, : 269 - 275
  • [30] A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor
    Xu, Shaoyi
    Shao, Haiming
    Li, Chuansheng
    Xing, Fangfang
    Wang, Yuqiao
    Li, Wei
    SENSORS, 2017, 17 (07)