On the Use of Ultrasonic Flowmeters for Cooling Energy Metering and Sub-Metering in Direct Expansion Systems

被引:0
|
作者
Aprea, Ciro [1 ]
Canale, Laura [2 ]
Dell'Isola, Marco [2 ]
Ficco, Giorgio [2 ]
Frattolillo, Andrea [3 ]
Maiorino, Angelo [1 ]
Petruzziello, Fabio [1 ]
机构
[1] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
[2] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, Via G Biasio 43, I-03043 Cassino, FR, Italy
[3] Univ Cagliari, Dept Civil Environm & Architecture Engn, Via Marengo 2, I-09123 Cagliari, CA, Italy
关键词
refrigeration; HVAC; flowmeter; energy metering; REFRIGERANT FLOW SYSTEMS; COMFORT MANAGEMENT; OCCUPANT BEHAVIOR; BUILDING ENERGY; PERFORMANCE; CONSUMPTION; AIR; IMPACT; MODEL;
D O I
10.3390/en16124775
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Energy Efficiency Directive (EED, Directive 2012/27/EU) has made mandatory the installation of individual metering systems in the case of buildings with centralized heating/cooling and hot water sources (multi-apartment and multi-purpose buildings), provided it is economically and technically feasible. Individual metering of heating/cooling systems is mainly based on thermal energy meters (TEM), which are widely used for direct metering in heating applications. On the other hand, direct metering of energy consumption in cooling systems still represents a challenge, given the different types of cooling units and the lack of regulations from the technical and legal points of view. In this context, this paper briefly overviews the available centralized cooling systems and the possible solutions for metering and sub-metering, which depend on the specific application. Vapour Compression Refrigeration (VCR) systems are spreading worldwide for air conditioning applications. Particular attention has been paid to the direct metering of cooling energy and specifically to refrigerant flow rate measurement, which represents a critical issue because of the small-diameter pipes and the different thermodynamic properties of the fluid used. Thus, an experimental campaign has been developed and carried out in order to compare a clamp-on ultrasonic flowmeter with a more accurate Coriolis one in a direct expansion (DE) system. The experimental tests have been performed at two different temperature conditions, showing a relative error in the mass flow rate measurements within & PLUSMN;10%.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] COMBUSTION CONTROL, FLOW METERING, TRIM PLANT-ENERGY USE
    KATZEL, J
    PLANT ENGINEERING, 1985, 39 (02) : 44 - 44
  • [32] Design of Wireless Remote High-voltage Energy Metering Systems
    Meng Aini
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 1455 - 1458
  • [33] DReAM: Per-Task DRAM Energy Metering in Multicore Systems
    Liu, Qixiao
    Moreto, Miquel
    Abella, Jaume
    Cazorla, Francisco J.
    Valero, Mateo
    EURO-PAR 2014 PARALLEL PROCESSING, 2014, 8632 : 111 - 123
  • [34] Concurrent Simulation Platform for Energy-Aware Smart Metering Systems
    Park, Seunghyun
    Kim, Hanjoo
    Moon, Hichan
    Heo, Jun
    Yoon, Sungroh
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2010, 56 (03) : 1918 - 1926
  • [35] Improving the Efficiency of Natural Draft Wet Cooling Towers by Using Smart Metering Systems
    Opris, Ioana
    Costinas, Sorina
    Ionescu, Cristina-Sorana
    Gogoase-Nistoran, Daniela-Elena
    2017 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM) & 2017 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP), 2017, : 134 - 139
  • [36] A combination method for metering gas-liquid two-phase flows of low liquid loading applying ultrasonic and Coriolis flowmeters
    Xing, Lanchang
    Geng, Yanfeng
    Hua, Chenquan
    Zhu, Hao
    Rieder, Alfred
    Drahm, Wolfgang
    Bezdek, Michal
    FLOW MEASUREMENT AND INSTRUMENTATION, 2014, 37 : 135 - 143
  • [37] A window into occupant-driven energy outcomes: Leveraging sub-metering infrastructure to examine psychosocial factors driving long-term outcomes of short-term competition-based energy interventions
    Konis, Kyle
    Orosz, Michael
    Sintov, Nicole
    ENERGY AND BUILDINGS, 2016, 116 : 206 - 217
  • [38] Low-Carbon Optimization of Integrated Energy Systems with Time-of-Use Carbon Metering on the User Side
    Yang, Yulong
    Zhang, Jialin
    Chen, Tao
    Yan, Han
    ENERGIES, 2024, 17 (09)
  • [39] Peer-to-Peer Sharing of Energy Storage Systems Under Net Metering and Time-of-Use Pricing
    Babu, K. Victor Sam Moses
    Vinay, K. Satya Surya
    Chakraborty, Pratyush
    IEEE ACCESS, 2023, 11 : 3118 - 3128
  • [40] Study of possibilities to store energy virtually in a grid (VESS) with the use of smart metering
    Kolasa, Piotr
    Janowski, Miroslaw
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 79 : 1513 - 1517