Hybrid SiC Pixel Detector for Charged-Particle Beam Monitor

被引:0
|
作者
Kishishita, Tetsuichi [1 ,2 ]
Kosugi, Ryoji [3 ]
Fujita, Yowichi [2 ]
Fukao, Yoshinori [2 ]
Kojima, Kazutoshi [3 ]
Masumoto, Keiko [3 ]
Nishiguchi, Hajime [2 ]
Tanaka, Manobu M. [2 ]
Tanaka, Yasunori [3 ]
机构
[1] Grad Univ Adv Studies, Dept Accelerator Sci, SOKENDAI, Hayama, Kanagawa 2400115, Japan
[2] High Energy Accelerator Res Org, Inst Particle & Nucl Studies, KEK, Tsukuba, Ibaraki 3050801, Japan
[3] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058560, Japan
关键词
Analog front-end; low noise; minimum ionizing particle (MIP) detectors; p-n diode; pixel detectors; silicon carbide (SiC); SILICON-CARBIDE; X-RAY; NOISE; IRRADIATION; NEUTRON;
D O I
10.1109/TNS.2023.3265318
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on the hybrid silicon carbide (SiC) pixel detector for charged-particle beam monitors in high-energy physics experiments. To demonstrate comparable performances of the state-of-the-art Si pixel detectors, SiC pixel sensors with a die size of 25 mm(2) were fabricated based on the p-n diode structure. We combined 12 x 12 diodes of a pixel size of 160 and 270 mu m pitches with the dedicated readout application-specific integrated circuit (ASIC) by indium and gold (In/Au) stud-bump technology. The front-end chip was designed in 0.35-mu m complementary metal oxide semiconductor (CMOS) technology, with consideration of a hybrid configuration. Each pixel circuit consists of a charge-sensitive amplifier (CSA) and bandpass filter, optimized for the SiC sensor. The low noise performance achieved an equivalent noise charge (ENC) of 55 +/- 5e(-) (rms). The spectrum of 241Am shows an energy resolution of 1.72 keV (FWHM) at 17.8-keV gamma-rays at room temperature. The obtained image with Sr-90 is a proof of a single minimum ionizing particle (MIP) detection capability with all pixels. Those results prospect a future application of the SiC pixel sensors to high-intensity proton extinction monitors in the coherent muon-to-electron transition (COMET) muon experiment at the Japan proton accelerator research complex (J-PARC).
引用
收藏
页码:1210 / 1214
页数:5
相关论文
共 50 条
  • [31] SYMMETRICAL SYSTEMS IN CHARGED-PARTICLE BEAM TRANSPORT
    MERRY, CM
    CORNELL, JC
    SOUTH AFRICAN JOURNAL OF PHYSICS - SUID-AFRIKAANSE TYDSKRIF VIR FISIKA, 1983, 6 (01): : 12 - 21
  • [32] SYMMETRIC, RELATIVISTIC CHARGED-PARTICLE BEAM EQUILIBRIA
    KADISH, A
    PHYSICS OF FLUIDS, 1981, 24 (07) : 1358 - 1363
  • [33] An ideal circular charged-particle beam system
    Bemis, T.
    Bhatt, R. J.
    Chen, C.
    Zhou, J.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 2243 - +
  • [34] ULTRASOUND EXCITATION IN METALS BY CHARGED-PARTICLE BEAM
    AKHIEZER, IA
    LAZURIKE.VT
    FIZIKA TVERDOGO TELA, 1972, 14 (12): : 3693 - 3694
  • [35] PERFORMANCE OF A SCINTILLATOR BEAM MONITOR SYSTEM FOR HIGH-INTENSITY SECONDARY CHARGED-PARTICLE BEAMS
    WANGLER, TP
    VIGDOR, SE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 601 - 601
  • [36] Equations for the envelope of a curvilinear charged-particle beam
    Naumov, ND
    DOKLADY PHYSICS, 2000, 45 (07) : 308 - 310
  • [37] Equations for the envelope of a curvilinear charged-particle beam
    N. D. Naumov
    Doklady Physics, 2000, 45 : 308 - 310
  • [38] A POSITION-SENSITIVE PHOTON DETECTOR USED AS A CHARGED-PARTICLE DETECTOR
    LINDROOS, M
    SKEPPSTEDT, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (1-2): : 225 - 228
  • [39] SELECTION OF CHARGED-PARTICLE DETECTOR FOR EXTENSIVE AIR SHOWERS
    VASHKEVICH, VV
    NECHIN, YA
    KHRENOV, BA
    KHRISTIANSEN, GB
    POMERANTSEV, VV
    SENCHISHIN, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (03) : 523 - 528
  • [40] CHARGED-PARTICLE DETECTOR EXPERIMENTS FOR MODERN PHYSICS LABORATORY
    DUGGAN, JL
    ADAMS, WD
    SCROGGS, RJ
    ANTHONY, LS
    AMERICAN JOURNAL OF PHYSICS, 1967, 35 (07) : 631 - +