Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker

被引:1
|
作者
Wang, Mengyue [1 ]
Gao, Feng [1 ]
Ni, Shoujie [1 ]
Song, Yanan [1 ,2 ]
Wang, Cai [1 ]
Li, Qian [1 ]
Zhao, Peng [1 ]
机构
[1] Shandong First Med Univ & Shandong Acad Med Sci, Affiliated Hosp 2, Tai An, Shandong, Peoples R China
[2] Qingdao Univ, Qingdao Med Coll, Qingdao, Shandong, Peoples R China
关键词
THI; AuNP; immunosensor; SAH; IL-6; TNF-ALPHA; IL-6; NANOCOMPOSITE; NANOPARTICLES; EXPRESSION; VASOSPASM;
D O I
10.3389/fbioe.2023.1153987
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: In clinical work, the realization of an early diagnosis of Subarachnoid hemorrhage (SAH) is primarily based on conventional computed tomography (CT), MR angiography, transcranial Doppler (TCD) ultrasound, and neurological assessments. However, the association between imaging manifestations and clinical findings is insufficiently perfect, particularly in SAH patients in acute phases with a lower amount of blood. The establishment of a direct, rapid and ultra-sensitive detection method based on electrochemical biosensors has emerged as a new competitive challenge in disease biomarkers research.Methods: In this study, a novel free-labeled electrochemical immunosensor for rapidly and sensitively detecting IL-6 in subarachnoid hemorrhage (SAH) blood has been developed using Au nanospheres-thionine composites (AuNPs/THI) as the interface modified on the electrode. Then, we detected IL-6 in blood samples from SAH patients by (enzyme-linked immunosorbent assay) ELISA and electrochemical immunosensor.Results: Under the best conditions, the developed electrochemical immunosensor exhibited a wide linear range from 10(-2) ng/mL to 10(2) ng/mL with a low detection limit of 1.85 pg/mL. Furthermore, when the immunosensor was employed in the analysis of IL-6 in 100% serum, the results obtained by electrochemical immunoassay were consistent with those obtained by ELISA without suffering from other significant biological interference.Discussion: The designed electrochemical immunosensor realizes the detection of IL-6 in actual serum samples with high accuracy and sensitivity, and could potentially become a promising technique for applications in the clinical diagnosis of SAH.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A label-free electrochemical immunosensor based on poly(thionine)-SDS nanocomposites for CA19-9 detection
    Jiang, Zhouqian
    Zhao, Chengfei
    Lin, Liqing
    Weng, Shaohuang
    Liu, Qicai
    Lin, Xinhua
    ANALYTICAL METHODS, 2015, 7 (11) : 4508 - 4513
  • [22] An electrochemical immunosensor on a carbon nanofiber/gold nanoparticles platform for the detection of alpha-feto protein cancer biomarker
    Olorundare, Foluke O. G.
    Sipuka, Dimpo S.
    Sebokolodi, Tsholofelo I.
    Makaluza, Sesethu
    Midzi, Nyasha
    Kodama, Tetsuya
    Arotiba, Omotayo A.
    Nkosi, Duduzile
    SENSING AND BIO-SENSING RESEARCH, 2023, 41
  • [23] Development of an electrochemical immunosensor based on gold nanoparticles incorporated chitosan biopolymer nanocomposite film for the detection of prostate cancer using PSA as biomarker
    Suresh, Lakkavarapu
    Brahman, Pradeep Kumar
    Reddy, Kasarla Ramakrushna
    Bondili, J. S.
    ENZYME AND MICROBIAL TECHNOLOGY, 2018, 112 : 43 - 51
  • [24] Dual gold nanostructure-based electrochemical immunosensor for CA125 detection
    Kumar, Nitin
    Sharma, Shivesh
    Nara, Seema
    APPLIED NANOSCIENCE, 2018, 8 (07) : 1843 - 1853
  • [25] A label-free electrochemical immunosensor based on gold nanoparticles for direct detection of atrazine
    Liu, Xia
    Li, Wen-Jin
    Li, Lei
    Yang, Yang
    Mao, Lu-Gang
    Peng, Zhang
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 408 - 414
  • [26] Sensitive electrochemical gold nanoparticle-based immunosensor for norovirus detection in food samples
    Janicka, Paulina
    Baluta, Sylwia
    Winiarski, Juliusz
    Halicka-Stepien, Kinga
    Pogorzelska, Aleksandra
    Cabaj, Joanna
    Pala, Katarzyna
    Bazanow, Barbara
    RSC ADVANCES, 2024, 14 (09) : 6028 - 6040
  • [27] Dual gold nanostructure-based electrochemical immunosensor for CA125 detection
    Nitin Kumar
    Shivesh Sharma
    Seema Nara
    Applied Nanoscience, 2018, 8 : 1843 - 1853
  • [28] Carboxylic group riched graphene oxide based disposable electrochemical immunosensor for cancer biomarker detection
    Rauf, Sajid
    Mishra, Geetesh K.
    Azhar, Jahanzaib
    Mishra, Rupesh K.
    Goud, K. Yugender
    Nawaz, Muhammad Azhar Hayat
    Marty, Jean Louis
    Hayat, Akhtar
    ANALYTICAL BIOCHEMISTRY, 2018, 545 : 13 - 19
  • [29] Design and fabrication of an electrochemical-based nanofibrous immunosensor for detection of prostate cancer biomarker, PSMA
    Rezaei, Zahra
    Alemzadeh, Iran
    Vossoughi, Manouchehr
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2022, 33 (06) : 1967 - 1977
  • [30] Electrochemical impedance immunosensor based on gold nanoparticles and aryl diazonium salt functionalized gold electrodes for the detection of antibody
    Liu, Guozhen
    Liu, Jingquan
    Davis, Thomas P.
    Gooding, J. Justin
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (08): : 3660 - 3665