Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker

被引:1
|
作者
Wang, Mengyue [1 ]
Gao, Feng [1 ]
Ni, Shoujie [1 ]
Song, Yanan [1 ,2 ]
Wang, Cai [1 ]
Li, Qian [1 ]
Zhao, Peng [1 ]
机构
[1] Shandong First Med Univ & Shandong Acad Med Sci, Affiliated Hosp 2, Tai An, Shandong, Peoples R China
[2] Qingdao Univ, Qingdao Med Coll, Qingdao, Shandong, Peoples R China
关键词
THI; AuNP; immunosensor; SAH; IL-6; TNF-ALPHA; IL-6; NANOCOMPOSITE; NANOPARTICLES; EXPRESSION; VASOSPASM;
D O I
10.3389/fbioe.2023.1153987
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: In clinical work, the realization of an early diagnosis of Subarachnoid hemorrhage (SAH) is primarily based on conventional computed tomography (CT), MR angiography, transcranial Doppler (TCD) ultrasound, and neurological assessments. However, the association between imaging manifestations and clinical findings is insufficiently perfect, particularly in SAH patients in acute phases with a lower amount of blood. The establishment of a direct, rapid and ultra-sensitive detection method based on electrochemical biosensors has emerged as a new competitive challenge in disease biomarkers research.Methods: In this study, a novel free-labeled electrochemical immunosensor for rapidly and sensitively detecting IL-6 in subarachnoid hemorrhage (SAH) blood has been developed using Au nanospheres-thionine composites (AuNPs/THI) as the interface modified on the electrode. Then, we detected IL-6 in blood samples from SAH patients by (enzyme-linked immunosorbent assay) ELISA and electrochemical immunosensor.Results: Under the best conditions, the developed electrochemical immunosensor exhibited a wide linear range from 10(-2) ng/mL to 10(2) ng/mL with a low detection limit of 1.85 pg/mL. Furthermore, when the immunosensor was employed in the analysis of IL-6 in 100% serum, the results obtained by electrochemical immunoassay were consistent with those obtained by ELISA without suffering from other significant biological interference.Discussion: The designed electrochemical immunosensor realizes the detection of IL-6 in actual serum samples with high accuracy and sensitivity, and could potentially become a promising technique for applications in the clinical diagnosis of SAH.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Electrochemical immunosensor based on nanoporpus gold loading thionine for carcinoembryonic antigen
    Sun, Xiaobin
    Ma, Zhanfang
    ANALYTICA CHIMICA ACTA, 2013, 780 : 95 - 100
  • [2] A paper-based electrochemical immunosensor with reduced graphene oxide/thionine/gold nanoparticles nanocomposites modification for the detection of cancer antigen 125
    Fan, Yan
    Shi, Shengyu
    Ma, Junshuang
    Guo, Yaohua
    BIOSENSORS & BIOELECTRONICS, 2019, 135 : 1 - 7
  • [3] Electrochemical immunosensor for detection of topoisomerase based on graphene-gold nanocomposites
    Zhong, Guang-Xian
    Wang, Peng
    Fu, Fei-Huan
    Weng, Shao-Huang
    Chen, Wei
    Li, Shao-Guang
    Liu, Ai-Lin
    Wu, Zhao-Yang
    Zhu, Xia
    Lin, Xin-Hua
    Lin, Jian-Hua
    Xia, Xing-Hua
    TALANTA, 2014, 125 : 439 - 445
  • [4] Electrochemical Immunosensor for Early Detection of β-Amyloid Alzheimer's Disease Biomarker Based on Aligned Carbon Nanotubes Gold Nanocomposites
    Ranjan, Pushpesh
    Khan, Raju
    BIOSENSORS-BASEL, 2022, 12 (11):
  • [5] Electrochemical aptamer/antibody based sandwich immunosensor for the detection of EGFR, a cancer biomarker, using gold nanoparticles as a signaling probe
    Ilkhani, Hoda
    Sarparast, Morteza
    Noori, Abolhassan
    Bathaie, S. Zahra
    Mousavi, Mir F.
    BIOSENSORS & BIOELECTRONICS, 2015, 74 : 491 - 497
  • [6] A Label-free Electrochemical Immunosensor for Carcinoembryonic Antigen Based on Graphene and Thionine
    Han, JingMan
    Ma, ZhanFang
    ADVANCED RESEARCH ON BIOCHEMICAL MATERIALS AND NANOTECHNOLOGY APPLICATION, 2013, 643 : 29 - 32
  • [7] A novel label-free electrochemical immunosensor based on graphene and thionine nanocomposite
    Wei, Qin
    Mao, Kexia
    Wu, Dan
    Dai, Yuxue
    Yang, Jian
    Du, Bin
    Yang, Minghui
    Li, He
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01) : 314 - 318
  • [8] Liquid crystal and gold nanoparticles applied to electrochemical immunosensor for cardiac biomarker
    Zapp, Eduardo
    Westphal, Eduard
    Gallardo, Hugo
    de Souza, Bernardo
    Vieira, Iolanda Cruz
    BIOSENSORS & BIOELECTRONICS, 2014, 59 : 127 - 133
  • [9] A label-free electrochemical immunosensor based on gold nanoparticles for detection of paraoxon
    Hu, SQ
    Xie, JW
    Xu, QH
    Rong, KT
    Shen, GL
    Yu, RQ
    TALANTA, 2003, 61 (06) : 769 - 777
  • [10] Gold nanoparticles-reduced graphene oxide based electrochemical immunosensor for the cardiac biomarker myoglobin
    Singh, Suman
    Tuteja, Satish K.
    Sillu, Devendra
    Deep, Akash
    Suri, C. Raman
    MICROCHIMICA ACTA, 2016, 183 (05) : 1729 - 1738