Intraoperative 3D imaging in plate osteosynthesis of proximal humerus fractures

被引:3
|
作者
Boehringer, Alexander [1 ]
Cintean, Raffael [1 ]
Eickhoff, Alexander [1 ]
Gebhard, Florian [1 ]
Schuetze, Konrad [1 ]
机构
[1] Ulm Univ, Dept Trauma Hand & Reconstruct Surg, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Proximal humerus fracture; PHILOS locking plate; Bone cement screw tip augmentation; Intraoperative 3D image intensifier; Digital volume tomography; Screw cutout; SCREW; AUGMENTATION;
D O I
10.1007/s00402-023-04820-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionProximal humerus fractures are common and often associated with osteoporosis in the elderly. Unfortunately, the complication and revision rate for joint-preserving surgical treatment using locking plate osteosynthesis is still high. Problems include insufficient fracture reduction and implant misplacement. Using conventional intraoperative two dimensional (2D) X-ray imaging control in only two planes, a completely error-free assessment is not possible.Materials and methodsThe feasibility of intraoperative three-dimensional (3D) imaging control for locking plate osteosynthesis with screw tip cement augmentation of proximal humerus fractures was retrospectively studied in 14 cases with an isocentric mobile C-arm image intensifier set up parasagittal to the patients.ResultsThe intraoperative digital volume tomography (DVT) scans were feasible in all cases and showed excellent image quality. One patient showed inadequate fracture reduction in the imaging control, which then could be corrected. In another patient, a protruding head screw was detected, which could be replaced before augmentation. Cement distribution in the humeral head was consistent around the screw tips with no leakage into the joint.ConclusionThis study shows that insufficient fracture reduction and implant misplacement can be easily and reliably detected by intraoperative DVT scan with an isocentric mobile C-arm set up in the usual parasagittal position to the patient.
引用
收藏
页码:4993 / 5000
页数:8
相关论文
共 50 条
  • [31] To Detect the Outcome of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Ahmed, Nasir
    Khan, Tarique Ali
    Anwar, Muhammad Absar
    Ali, Ahmed
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (01): : 281 - 285
  • [32] Fractures of the proximal humerus. Possible reasons for failed osteosynthesis
    Grechenig, W.
    Pichler, W.
    Weiglein, A.
    [J]. TRAUMA UND BERUFSKRANKHEIT, 2008, 10 : 53 - 58
  • [33] Minimally invasive osteosynthesis with locked plate with no intraoperative imaging for tibial fractures in dogs
    Rosa-Ballaben, N. M.
    Filgueira, F. G. F.
    Avante, M. L.
    Chung, D. G.
    Moraes, P. C.
    Minto, B. W.
    [J]. ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2017, 69 (02) : 347 - 354
  • [34] NEW OSTEOSYNTHESIS, SPIRAL PIN NAILING, FOR FRACTURES OF THE PROXIMAL HUMERUS
    YANO, S
    ISCHIDA, F
    HIROHATA, K
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1984, 122 (04): : 527 - 527
  • [35] TRANSACROMIAL PERCUTANEOUS OSTEOSYNTHESIS WITH KIRSCHNER WIRES IN PROXIMAL FRACTURES OF THE HUMERUS
    JASCHKE, W
    HOPF, G
    GERSTNER, C
    HIEMER, W
    [J]. ZENTRALBLATT FUR CHIRURGIE, 1981, 106 (09): : 618 - 621
  • [36] Locking Plate Fixation for Proximal Humerus Fractures
    Burke, Neil G.
    Kennedy, Jim
    Green, Connor
    Dodds, Michael K.
    Mullett, Hannan
    [J]. ORTHOPEDICS, 2012, 35 (02) : E250 - E254
  • [37] Minimally Invasive Plate Osteosynthesis for Proximal Humerus Fractures: A Retrospective Study Describing Principles and Advantages of the Technique
    Alberio, Riccardo Luigi
    Del Re, Matteo
    Grassi, Federico Alberto
    [J]. ADVANCES IN ORTHOPEDICS, 2018, 2018
  • [38] Dual plate for comminuted proximal humerus fractures
    Choi, Sungwook
    Seo, Kyu-Bum
    Kwon, Yong Suk
    Kang, Hyunseong
    Cho, Changhee
    Rho, Joseph Y.
    [J]. ACTA ORTHOPAEDICA BELGICA, 2019, 85 (04): : 429 - 436
  • [39] Locked Plate Fixation for Fractures of the Proximal Humerus
    Ricci, William M.
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2007, 22 (04) : 192 - 196
  • [40] Locking Plate Fixation of Proximal Humerus Fractures
    Strohm, Peter C.
    Koestler, Wolfgang
    Suedkamp, Norbert P.
    [J]. TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2005, 6 (01): : 8 - 13