Effect of vacuum scheme on radiative sky cooling performance

被引:8
|
作者
Hu, Mingke [1 ]
Zhao, Bin [2 ]
Suhendri [1 ]
Cao, Jingyu [3 ]
Wang, Qiliang [4 ]
Riffat, Saffa [1 ]
Su, Yuehong [1 ]
Pei, Gang [2 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230027, Peoples R China
[3] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[4] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
基金
中国国家自然科学基金; 欧盟地平线“2020”;
关键词
Radiative cooling; Vacuum; Stagnation temperature; Cooling power;
D O I
10.1016/j.applthermaleng.2022.119657
中图分类号
O414.1 [热力学];
学科分类号
摘要
Relatively low cooling power density is one of the main barriers to wider promotion of radiative sky cooling (RSC) technology. Vacuum scheme has been proposed to minimize the non-radiative cooling loss and thus improve the cooling capacity. However, systematic research to elucidate the effect of the vacuum mechanism on the RSC performance is still lacking. Therefore, in the present study, an RSC module with four vacuum structures is proposed to evaluate the performance variation resulting from the vacuum scheme. A quasi-steady state mathematical model is developed to characterize the cooling performance of the four RSC modules under different operation conditions. Results suggested that the vacuum strategy can further elevate the cooling ca-pacity if the typical RSC (TRSC) module itself can realize all-day sub-ambient cooling. However, if the TRSC cannot achieve sub-ambient cooling during peak sun hours, the vacuum scheme will deteriorate rather than ameliorate the cooling performance. On a typical summer day in Shanghai, vacuumization in both cavities en-ables a further temperature reduction of 10.21 degrees C during the nighttime, but this value decreases to only 3.39 degrees C during the daytime. The cooling power enhancement resulting from the vacuum scheme is limited in real-world dynamic operation with the thermal carrier. At a reasonable temperature gap of 5 degrees C between the emitter and ambient air, the extra cooling gain is less than 5.10 W/m2. Hence, considering the addition of energy con-sumption and system complexity caused by the vacuum unit, it may not be advisable to pursue better cooling performance of a stand-alone RSC collector/system through introducing a vacuum strategy, unless realizing a deep stagnation emitter temperature is targeted.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Research on the influence and optimization of sunshade effect on radiative cooling performance
    Lv, Song
    Sun, Xinyi
    Zhang, Bolong
    Lai, Yin
    Yang, Jiahao
    ENERGY, 2024, 297
  • [32] A review of the application of radiative sky cooling in buildings: Challenges and optimization
    Wu, Yifan
    Zhao, Hengxin
    Sun, Hongli
    Duan, Mengfan
    Lin, Borong
    Wu, Shuangdui
    ENERGY CONVERSION AND MANAGEMENT, 2022, 265
  • [33] Theoretical investigation of two ideal radiative cooling materials and radiative sky water-cooling module with ideal selective radiative materials
    Yang, Xiufeng
    Wang, Shuting
    Zhang, Dong
    Yu, Jia
    ENERGY AND BUILDINGS, 2024, 323
  • [34] Variability in clear-sky longwave radiative cooling of the atmosphere
    Allan, Richard P.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2006, 111 (D22)
  • [35] Cellulose-upgraded polymer films for radiative sky cooling
    Chowdhury, Farsad Imtiaz
    Xu, Qiwei
    Sinha, Kaustubh
    Wang, Xihua
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2021, 272
  • [36] Radiative sky cooling: fundamental physics, materials, structures, and applications
    Sun, Xingshu
    Sun, Yubo
    Zhou, Zhiguang
    Alam, Muhammad Ashraful
    Bermel, Peter
    NANOPHOTONICS, 2017, 6 (05) : 997 - 1015
  • [37] The Mathematical Modeling and Performance of Sky Radiative Coolers
    Zhuang, Zhaoyi
    Yang, Xuebin
    Xie, Kun
    Tang, Mengyan
    Xu, Yanbiao
    Ben, Xianye
    BUILDINGS, 2023, 13 (12)
  • [38] Colored radiative cooling: How to balance color display and radiative cooling performance
    Xi, Wang
    Liu, Yida
    Zhao, Weixian
    Hu, Run
    Luo, Xiaobing
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 170
  • [39] Consistent Assessment of the Cooling Performance of Radiative Cooling Materials
    Bu, Kunlang
    Huang, Xingyi
    Li, Xiangyu
    Bao, Hua
    ADVANCED FUNCTIONAL MATERIALS, 2023, 33 (51)
  • [40] Radiative sky cooling in low-medium concentration photovoltaic systems
    Li, Yingfeng
    Zhang, Laiyu
    Gao, Wenxiang
    Liu, Yingjian
    An, Jiayuan
    Liu, Zhihan
    Ju, Xing
    Li, Meicheng
    APPLIED THERMAL ENGINEERING, 2023, 221