Development and Implementation of Mine Ventilation Network Calibration Using a Two-step Method

被引:4
|
作者
Wu, Fengliang [1 ]
Zhao, Han [1 ]
Wang, Tong [1 ]
机构
[1] Xian Univ Sci & Technol, Coll Safety Sci & Engn, Xian 710054, Peoples R China
基金
中国国家自然科学基金;
关键词
Mine ventilation network; Resistance calibration; Optimization method; Airway resistance;
D O I
10.1007/s42461-023-00910-2
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Calibrating an entire mine ventilation network model from survey data has long been considered a challenging and sometimes impractical task. This paper proposes a solution to this issue with the development of a quadratic programming optimization model. The optimization model takes the minimum modification of input resistances as the objective function, uses the mesh pressure equations as equality constraints, and incorporates the lower limits of airway resistances as inequality constraints. A two-step method is developed to solve the model, which includes finding an initial feasible solution and iteratively solving the final solution using the active set method. A computer program has been developed to implement the optimization model. To demonstrate its practicality, a study case using a 35-branch ventilation network is presented, which indicates that the solution process converges after only 57 iterations, a significant improvement over the times of trial and error, which could reach 3.4 x 1010 for the worst-case scenario. Additionally, it is shown that considering only the equality constraints results in negative resistances, while incorporating the lower limits of resistance ensures that the corrected resistances are within a reasonable range. Using the resistance corrected by the optimal model to simulate the ventilation system via traditional methods generates quantities and fan pressures that perfectly match the measured values, eliminating the tedious process of manually adjusting airway resistances repeatedly.
引用
收藏
页码:193 / 205
页数:13
相关论文
共 50 条
  • [31] High precision two-step calibration method for the fish-eye camera
    Tu, Bo
    Liu, Lu
    Liu, Yihui
    Jin, Ye
    Tang, Junxiong
    APPLIED OPTICS, 2013, 52 (07) : C37 - C42
  • [32] Two-step calibration method for obtaining the optical constants of crystallized chalcogenide films
    Liu, Xinli
    Mao, Ning
    Zheng, Jiacheng
    Lin, Changgui
    Zhang, Peiqing
    Shen, Xiang
    Dai, Shixun
    Song, Baoan
    OPTICS AND LASER TECHNOLOGY, 2023, 162
  • [33] An iterative two-step method for online item calibration in CD-CAT
    Xiaofeng Yu
    Ying Cheng
    Behavior Research Methods, 2024, 56 : 233 - 257
  • [34] A Two-Step Disentanglement Method
    Hadad, Naama
    Wolf, Lior
    Shahar, Moni
    2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2018, : 772 - 780
  • [35] Development in vivo of rabbit morulae after freezing using a two-step cooling method
    LopezBejar, MA
    LopezGatius, F
    Rutllant, J
    Camon, J
    Labernia, J
    Santolaria, P
    REPRODUCTION IN DOMESTIC ANIMALS, 1996, 31 (4-5) : 661 - 664
  • [36] Development of a two-step touch method for website navigation on smartphones
    Jung, Kihyo
    Jang, Jinah
    APPLIED ERGONOMICS, 2015, 48 : 148 - 153
  • [37] Development of Two-Step Method for Fast Chloride MSR Neutronics
    Lawson, Kyra
    Brown, Nicholas R.
    NUCLEAR TECHNOLOGY, 2024, 210 (11) : 2133 - 2150
  • [38] Two-Step Gravimetric Study of Mine Dusts.
    Tkachev, V.V.
    Meditsina Truda I Promyshlennaya Ekologiya, 1979, (05): : 32 - 36
  • [39] Calibration of Mine Ventilation Network Models Using the Non-Linear Optimization Algorithm
    Xu, Guang
    Huang, Jinxin
    Nie, Baisheng
    Chalmers, Duncan
    Yang, Zhuoming
    ENERGIES, 2018, 11 (01):
  • [40] Improvement of the distribution network state estimation with increase of accurate information and using a two-step method
    Amiri, Karim
    Kazemzadeh, Rasool
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2020, 28 (04) : 1984 - 2003