FINITE ELEMENT ANALYSIS OF CUSTOMIZED KNEE IMPLANTS BY VARYING LOADS DURING FLEXION-EXTENSION MOVEMENT

被引:0
|
作者
Alshewaier, Shady A. A. [1 ]
Alshehri, Majed Ali Ghurmallah [2 ]
Begum, S. Sabarunisha [3 ]
Sikkandar, Mohamed Yacin [2 ]
Almukil, Ali Abdullah A. [2 ]
Alhazmi, Aishah Mohammad [4 ]
机构
[1] Majmaah Univ, Coll Appl Med Sci, Dept Phys Therapy, Al Majmaah 11952, Saudi Arabia
[2] Majmaah Univ, Coll Appl Med Sci, Dept Med Equipment Technol, Al Majmaah 11952, Saudi Arabia
[3] PSR Engn Coll, Dept Biotechnol, Sivakasi 626140, Tamil Nadu, India
[4] Ad Diriyah Hosp, Minist Hlth, Diriyah, Saudi Arabia
关键词
Total knee replacement; knee osteoarthritis; off-the-shelf knee; patient-specific; biomechanical; ARTHROPLASTY; BIOMECHANICS;
D O I
10.1142/S021951942340016X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A customized knee implant numerical modeling using finite element analysis (FEA) during flexion extension has been investigated in this paper with varying loads with an objective of studying its kinematics. Computed tomography (CT) images of 15 osteoarthritis subjects' images were used in this work. Various morphological characteristics were extracted from clinical images using a commercial CAE software and biomechanical properties were studied on applying standard loads on customized implant and off-the-shelf (OTS) implants. Patient-specific knee implants have been designed according to the morphological characteristics and bone dimension of patient with compressive loads (1500, 1700 and 3000 N) during normal gait and were compared with the normal knee. Results showed that the stresses are distributed equally to the spacer and the tibial plate, unlike the standard femoral component where the stresses get concentrated on the cut edges. In compressive load, active stress and strain (similar to 5-20 MPa) are lesser (similar to 5%) and in flexion extension also lesser with a scaling factor of 0.785 and 1.0. The designed implant was found to produce similar biomechanical properties when compared to normal knee joint and thus it can be considered as a valuable implant and could replace the standard OTS knee implants.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Accent Stabilizes 1:2 Sensorimotor Synchronization of Rhythmic Knee Flexion-Extension Movement in Upright Stance
    Etani, Takahide
    Miura, Akito
    Okano, Masahiro
    Shinya, Masahiro
    Kudo, Kazutoshi
    FRONTIERS IN PSYCHOLOGY, 2019, 10
  • [22] FUNCTIONAL ANALYSIS OF THE TRUNK FLEXION-EXTENSION THROUGH GAUSSIAN FUNCTIONS FITTING OF THE MOVEMENT PROFILE
    Amici, Cinzia
    Piovanelli, Barbara
    Ragni, Federica
    Formicola, Raffaele
    Cappellini, Valter
    Candiani, Gabriele
    Borboni, Alberto
    Negrini, Stefano
    PROCEEDINGS OF ASME 2021 INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, IDETC-CIE2021, VOL 7, 2021,
  • [23] Patterns in the knee flexion-extension moment profile during stair ascent and descent in patients with total knee arthroplasty
    McClelland, Jodie A.
    Feller, Julian A.
    Menz, Hylton B.
    Webster, Kate E.
    JOURNAL OF BIOMECHANICS, 2014, 47 (08) : 1816 - 1821
  • [24] Muscle fatigue tracking during dynamic elbow flexion-extension movements with a varying hand load
    Yoon, Woojin
    Shin, Gwanseob
    APPLIED ERGONOMICS, 2024, 116
  • [25] Muscle fatigue tracking during dynamic elbow flexion-extension movements with a varying hand load
    Yoon, Woojin
    Shin, Gwanseob
    Applied Ergonomics, 2024, 116
  • [26] Decoding Muscle Excitation Primitives from Slow Cortical Potentials During Knee Flexion-Extension
    Ubeda, A.
    Sartori, M.
    del-Ama, A. J.
    Gil-Agudo, A.
    Azorin, J. M.
    Farina, D.
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION II, VOLS 1 AND 2, 2017, 15 : 1151 - 1156
  • [27] Electrical manifestations of muscle fatigue during concentric and eccentric isokinetic knee flexion-extension movements
    Molinari, Filippo
    Knaflitz, Marco
    Bonato, Paolo
    Actis, Maria Vittoria
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) : 1309 - 1316
  • [28] ANALYSIS OF THE INSTANTANEUS AXIS OF THE NECK FLEXION-EXTENSION MOVEMENT BY MEANS OF VIDEO ANALYSIS: RELIABILITY AND ERROR ANALYSIS
    Venegas Toro, William
    Page del Pozo, Alvaro
    Zambrano Orejuela, Ivan
    Ruiz Cruz, Christopher
    3C TECNOLOGIA, 2018, 7 (01): : 79 - 92
  • [29] Defining the knee joint flexion-extension axis for purposes of quantitative gait analysis: An evaluation of methods
    Schache, Anthony G.
    Baker, Richard
    Lamoreux, Larry W.
    GAIT & POSTURE, 2006, 24 (01) : 100 - 109
  • [30] Surface EMG during isokinetic flexion-extension of the knee in hemiparetic patients: a one year later control
    Felicetti, G
    Contardi, A
    Rovescala, R
    Maestri, R
    8TH WORLD CONGRESS OF THE INTERNATIONAL REHABILITATION MEDICINE ASSOCIATION (IRMA VIII), PTS 1-2, 1997, : 1615 - 1620