Interrater reliability and concurrent validity of 4AT for the detection of postoperative delirium: A prospective cohort study

被引:1
|
作者
Muzzana, Chiara [1 ,3 ]
Mantovan, Franco [1 ,2 ]
Tappeiner, Waltraud [1 ]
Niederbacher, Sarah [2 ]
Huber, Markus Karl [2 ]
Ausserhofer, Dietmar [1 ]
机构
[1] Landesfachhsch Gesundheitsberufe Claudiana, Bolzano, Italy
[2] Krankenhaus Bruneck, Sudtiroler Sanitatsbetrieb, Brunico, Italy
[3] Landesfachhsch Gesundheitsberufe, Lorenz Bohlerstr 13, I-39100 Bolzano, Italy
来源
PFLEGE | 2023年 / 36卷 / 04期
关键词
Postoperative delirium assessment; 4 A's Test; reliability; validity; cohort study;
D O I
10.1024/1012-5302/a000939
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Interrater reliability and concurrent validity of 4AT for the detection of postoperative delirium: A prospective cohort studyAbstract. Background: Numerous tools for detecting postoperative delirium are available. Guidelines recommend the 4 A's Test (4AT). However, there is little evidence on the validity and reliability of the German version of 4AT. Aim: To assess the interrater reliability of the German version of 4AT test for the detection of postoperative delirium in general surgical and orthopedic-traumatological patients, and the concurrent validity with the Delirium Observation Screening Scale (DOS). Methods: The present work is part of a prospective cohort study with a sample of 202 inpatients (=65 years) who underwent surgery. The interrater reliability of the 4AT (intraclass coefficients) was determined with a subsample of 33 subjects who were rated by two nurses. Concurrent validity between the DOS scale and the 4AT was calculated using Pearson's correlation coefficient. Results: Interrater reliability for the 4AT total score and dichotomized total score were 0.92 (95% CI 0.84-0.96) and 0.98 (95% CI 0.95-0.98), respectively. The correlation between DOS and 4AT (Pearson) was 0.54 (p < 0.001). Conclusions: The 4A test can be used by nurses as a screening instrument for the detection of postoperative delirium in older patients on general surgery and orthopedic traumatology wards. In case of positive 4AT results further assessment by nurse experts or physicians is required.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [41] Regional cerebral oxygen saturation and postoperative delirium in endovascular surgery: a prospective cohort study
    Xiaohua Wang
    Kunpeng Feng
    Haixia Liu
    Yanhui Liu
    Ming Ye
    Guoguang Zhao
    Tianlong Wang
    Trials, 20
  • [42] Factors Related to Postoperative Delirium in Patients with Lower Limb Ischaemia: A Prospective Cohort Study
    Sasajima, Y.
    Sasajima, T.
    Azuma, N.
    Akazawa, K.
    Saito, Y.
    Inaba, M.
    Uchida, H.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 44 (04) : 411 - 415
  • [43] Letter to the editor regarding "Postoperative delirium risk in patients with hyperlipidemia: A prospective cohort study"
    Yang, Guanyu
    Chu, Qinjun
    JOURNAL OF CLINICAL ANESTHESIA, 2024, 98
  • [44] Diagnostic accuracy of the Dutch version of the 4AT for delirium detection in a mixed patient population and setting
    Pouw, Maaike A.
    Calf, Agneta H.
    Georg, Rita R.
    de Rooij, Sophia E.
    ter Maaten, Jan C.
    van Munster, Barbara C.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2023, 35 (08) : 1705 - 1710
  • [45] The temporal relationship between early postoperative delirium and postoperative cognitive dysfunction in older patients: a prospective cohort study
    Youngblom, Emily
    DePalma, Glen
    Sands, Laura
    Leung, Jacqueline
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (12): : 1084 - 1092
  • [46] Diagnostic accuracy of the Dutch version of the 4AT for delirium detection in a mixed patient population and setting
    Maaike A. Pouw
    Agneta H. Calf
    Rita R. Georg
    Sophia E. de Rooij
    Jan C. ter Maaten
    Barbara C. van Munster
    Aging Clinical and Experimental Research, 2023, 35 (8) : 1705 - 1710
  • [47] Child delirium assessment scale: Validity and reliability study
    Turan, Engin
    Manav, Gulay
    Baran, Gulbeyaz
    JOURNAL OF PSYCHIATRIC NURSING, 2024, 15 (02): : 175 - 184
  • [48] DIAGNOSTIC TEST ACCURACY OF THE 4AT FOR DELIRIUM DETECTION: SYSTEMATIC REVIEW AND META-ANALYSIS
    Tieges, Z.
    MacLullich, A. M. J.
    Anand, A.
    Cassaroni, M.
    O'Connor, M.
    Ryan, D.
    Saller, T.
    Arora, R.
    Chang, Y.
    Agarwal, K.
    Taffet, G.
    Quinn, T.
    Shenkin, S.
    Galvin, R.
    AGE AND AGEING, 2021, 50
  • [49] The Bird's Nest Drawing: A study of construct validity and interrater reliability
    Harmon-Walker, Gaelan
    Kaiser, Donna H.
    ARTS IN PSYCHOTHERAPY, 2015, 42 : 1 - 9
  • [50] Diagnostic Test Accuracy of the 4AT for Delirium Detection: A Systematic Review and Meta-Analysis
    Jeong, Eunhye
    Park, Jinkyung
    Lee, Juneyoung
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (20) : 1 - 15