Experimental and numerical study on the heat transfer enhancement over scalene and curved-side triangular ribs

被引:4
|
作者
Oleiwi, Ahmed [1 ]
Mohsen, A. M. [2 ,6 ]
Abdulkadhim, Ammar [3 ]
Abed, Azher M. [3 ]
Laidoudi, Houssem [4 ]
Abderrahmane, Aissa [5 ]
机构
[1] Univ Warith Al Anbiyaa, Air Conditioning & Refrigerat Tech Engn Dept, Karbala, Iraq
[2] Taylors Univ, Fac Innovat & Technol, Sch Engn, Subang Jaya, Malaysia
[3] Al Mustaqbal Univ Coll, Air Conditioning & Refrigerat Tech Engn Dept, Babylon, Iraq
[4] Univ Sci & Technol Oran, Mohamed BOUDIAF, Oran, Algeria
[5] Univ Mascara, Lab Phys Quant Matiere & Modelisat Math LPQ3M, Mascara, Algeria
[6] Taylors Univ, Fac Innovat & Technol, Sch Engn, Subang Jaya 47500, Malaysia
关键词
CFD; corrugated channel; heat transfer; mixed convection; CORRUGATED CHANNEL; FORCED-CONVECTION; HYDRAULIC CHARACTERISTICS; DESIGN CHARACTERISTICS; NATURAL-CONVECTION; NANOFLUIDS FLOW; ENCLOSURE; TUBES; WATER;
D O I
10.1002/htj.22835
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study examines the turbulent flow of mixed convection heat transfer enhancement within a rectangular channel considering three different novel shapes of ribs (smooth, scalene, and curved-side triangular). The investigations were conducted experimentally by developing a new test facility, while the numerical computations were carried out using the finite volume method. The experimental work involves constructing of the channel, ribs, and all equipment and measurement instruments. The numerical work is based on ANSYS FLUENT considering the k-epsilon turbulent model. The results are presented and compared in terms of Nusselt number, friction factor, and performance factors for Reynolds numbers ranging between 3000 and 12,000. By comparing the average values of the numerically obtained Nusselt number with experimental measurements, the data showed a close agreement with a maximum difference of 5%. It also found that scalene triangular ribs (STRs) provide better performance in terms of heat transfer, although introducing a slight increase in friction losses. STRs showed (20%) increase in Nusselt number compared with smooth channel, and 3%-6% increase in Nusselt number compared with curved-side triangular ribs (CTRs). In contrast, CTRs have a lower friction factor value of 5% compared with STRs at a low value of a Reynolds number of 3000. Furthermore, the Nusselt number changes significantly (250% increase) by increasing the value of the Reynolds number from 3000 to 12,000. A thermal performance factor of up to 1.28 was achieved for the STRs at the lowest range of Reynolds' number of 3000. The findings from the present study are of practical importance for industries requiring heat transfer enhancement techniques to improve heat transfer equipment performance.
引用
收藏
页码:3433 / 3452
页数:20
相关论文
共 50 条
  • [21] Experimental and numerical study of developed flow and heat transfer in coolant channels with 45 degree ribs
    Bonhoff, B
    Parneix, S
    Leusch, J
    Johnson, BV
    Schabacker, J
    Bölcs, A
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1999, 20 (03) : 311 - 319
  • [22] A Combined Numerical and Experimental Study of Heat Transfer in a Roughened Square Channel with 45 degrees Ribs
    Taslim, M. E.
    Liu, H.
    INTERNATIONAL JOURNAL OF ROTATING MACHINERY, 2005, 2005 (01) : 60 - 66
  • [23] Study on heat transfer enhancement in shell side
    Shen, JL
    Zhu, DS
    Fan, JM
    Qian, SW
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 1032 - 1037
  • [24] NUMERICAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT WITH THE USE OF γ-AL2O3/WATER NANOFLUID AND LONGITUDINAL RIBS IN A CURVED DUCT
    Soltanipour, Hosseinali
    Choupani, Parisa
    Mirzaee, Iraj
    THERMAL SCIENCE, 2012, 16 (02): : 469 - 480
  • [25] Numerical and Experimental Comparative Study on Nanofluids Flow and Heat Transfer in a Ribbed Triangular Duct
    Ahmed, H. E.
    Ahmed, M. I.
    Yusoff, M. Z.
    EXPERIMENTAL HEAT TRANSFER, 2016, 29 (06) : 759 - 780
  • [26] Numerical study of heat transfer enhancement by using protrusions in curved pin-fin arrays
    Yang, Ziyang
    Luo, Lei
    Cheng, Hao
    Yan, Han
    Du, Wei
    Zhou, Xun
    PHYSICS OF FLUIDS, 2024, 36 (05)
  • [27] Experimental study and numerical analysis of heat transfer enhancement and turbulent flow over shallowly dimpled channel surfaces
    Rao, Yu
    Zhang, Peng
    Xu, Yamin
    Ke, Hanbing
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 160
  • [28] Experimental and numerical investigation of convection heat transfer in a rectangular channel with angled ribs
    Lu, Ben
    Jiang, Pei-Xue
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2006, 30 (06) : 513 - 521
  • [29] Experimental and numerical investigation of convection heat transfer in channels with different types of ribs
    Peng, Wei
    Jiang, Pei-Xue
    Wang, Yang-Ping
    Wei, Bing-Yuan
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 2702 - 2708
  • [30] An experimental and numerical study of heat transfer and pressure loss in a rectangular channel with V-shaped ribs
    Maurer, Michael
    von Wolfersdorf, Jens
    Gritsch, Michael
    Proceedings of the ASME Turbo Expo 2006, Vol 3, Pts A and B: HEAT TRANSFER: GENERAL INTEREST, 2006, : 15 - 24