A Novel Two-Degrees-of-Freedom Current Controller Based on Virtual Impedance for Grid-Connected Inverters under Unbalanced Conditions

被引:1
|
作者
Budiwicaksana, Lukas Antonio [1 ]
Lee, Dong-Choon [1 ]
机构
[1] Yeungnam Univ, Dept Elect Engn, Gyongsan, South Korea
关键词
current controller; virtual impedance; unbalanced current suppression; harmonics suppression; HARMONIC SUPPRESSION;
D O I
10.1109/APEC43580.2023.10131603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a novel current controller for three-phase grid-connected inverters under unbalanced conditions, which is based on the series virtual impedance algorithm. Unlike the conventional methods, the transformation of unbalanced current to positive and negative sequence components is not required. Thus, the current controllers are only two, considering the controller is applied in the d-q synchronous reference frame (SRF). Here, the current controller regards unbalance as disturbance, so current reference and disturbance suppression responses can be separated. By doing separation, the controller has two degrees of freedom, meaning the suppression of disturbance does not affect the reference response. Simulation and experiments have been done to justify the effectiveness of the proposed method, which can suppress the current unbalance factor from 23.33 % to 0.13 % and current THD from 8.9 % to 3 %.
引用
收藏
页码:520 / 526
页数:7
相关论文
共 50 条
  • [21] Improved virtual synchronous control for grid-connected VSCs under grid voltage unbalanced conditions
    Shang, Lei
    Hu, Jiabing
    Yuan, Xiaoming
    Huang, Yunhui
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2019, 7 (01) : 174 - 185
  • [22] Current Improvement of a Grid-Connected Photovoltaic System under Unbalanced Voltage Conditions
    Mirhosseini, Mitra
    Pou, Josep
    Agelidis, Vassilios G.
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 66 - 72
  • [23] A Neutral-Point Voltage Controller With Hybrid Parameters for NPC Three-Level Grid-Connected Inverters Under Unbalanced Grid Conditions
    Lyu, Jianguo
    Wang, Jidong
    Hu, Wenbin
    Yan, Yiran
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2020, 8 (04) : 4367 - 4381
  • [24] Virtual admittance Based Current Control Strategy for Grid-connected inverters in Microgrid
    Cao Hai-Yan
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (12A): : 117 - 120
  • [25] Virtual Impedance-Based Active Damping for LCL Resonance in Grid-Connected Voltage Source Inverters with Grid Current Feedback
    Liu, Teng
    Liu, Zeng
    Liu, Jinjun
    Liu, Zipeng
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [26] Advanced Control of Grid-Connected Current Source Converter Under Unbalanced Grid Voltage Conditions
    Guo, Xiaoqiang
    Yang, Yong
    Zhang, Xue
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (12) : 9225 - 9233
  • [27] Design of a novel robust current controller for grid-connected inverter against grid impedance variations
    Wang, Jing
    Tyuryukanov, Ilya
    Monti, Antonello
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 110 : 454 - 466
  • [28] Impedance Modeling and Stability Analysis of Grid-connected Inverter Under Unbalanced Grid
    Xie B.
    Li P.
    Su J.
    Zheng W.
    Shi Y.
    Liu T.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 5196 - 5207
  • [29] Selective output impedance based control for grid-connected inverters
    Couto, H. P.
    Brandao, D. I.
    Silva, S. M.
    Caldognetto, T.
    Sanchez, S.
    Tedeschi, E.
    2019 21ST EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE '19 ECCE EUROPE), 2019,
  • [30] Impedance-Based Stability Criterion for Grid-Connected Inverters
    Sun, Jian