Wide metabolite coverage LC-MS/MS assay for the diagnosis of inherited metabolic disorders in urine

被引:1
|
作者
Ivanovova, Eliska [2 ]
Pisklakova, Barbora [1 ]
Dobesova, Dana [1 ]
Janeckova, Hana [1 ,2 ]
Foltenova, Hana [1 ,3 ]
Kvasnicka, Ales [1 ]
Pridavok, Matlis [1 ,4 ]
Bouchalova, Katerina [1 ,3 ]
de Sousa, Julie [5 ]
Friedecky, David [1 ,2 ,6 ]
机构
[1] Palacky Univ Olomouc, Fac Med & Dent, Olomouc, Czech Republic
[2] Univ Hosp Olomouc, Dept Clin Biochem, Lab Inherited Metab Disorders, Olomouc, Czech Republic
[3] Univ Hosp Olomouc, Dept Pediat, Olomouc, Czech Republic
[4] Natl Inst Childhood Dis, Ctr Inherited Metab Disorders, Bratislava, Slovakia
[5] Palacky Univ Olomouc, Dept Math Anal & Applicat Math, Olomouc, Czech Republic
[6] Univ Hosp Olomouc, Dept Clin Biochem, Zdravotniku 7, Olomouc 77900, Czech Republic
关键词
Inherited metabolic disorders; Diagnosis; Hydrophilic interaction chromatography; Liquid chromatography; Mass spectrometry; INBORN-ERRORS;
D O I
10.1016/j.talanta.2024.125699
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Objective: The laboratory diagnosis of inherited metabolic disorders (IMD) has undergone significant development in recent decades, mainly due to the use of mass spectrometry, which allows rapid multicomponent analysis of a wide range of metabolites. Combined with advanced software tools, the diagnosis becomes more efficient as a benefit for both physicians and patients. Methods: A hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry assay for determination of urinary purines, pyrimidines, N-acylglycines, N-acetylated amino acids, sugars, sugar alcohols and other diagnostically important biomarkers was developed and validated. Evaluation of the results consisting of utilisation of robust scaling and advanced visualization tools is simple and even suitable for urgent requirements. Results: The developed method, covering 65 biomarkers, provides a comprehensive diagnostic platform for 51 IMD. For most analytes, linearity with R-2 > 0.99, intra and inter-day accuracy between 80 and 120 % and precision lower than 20 % were achieved. Diagnostic workflow was evaluated on 47 patients and External Quality Assurance samples involving a total of 24 different IMD. Over seven years, more than 2300 urine samples from patients suspected for IMD have been routinely analysed. Conclusions: This method offers the advantage of a broad coverage of intermediate metabolites of interest and therefore may be a potential alternative and simplification for clinical laboratories that use multiple methods for screening these markers.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Development and validation of a HPLC method for quantification of rivastigmine in rat urine and identification of a novel metabolite in urine by LC-MS/MS
    Arumugam, Karthik
    Chamallamudi, Mallikarjuna Rao
    Gilibili, Ravindranath Reddy
    Mullangi, Ramesh
    Ganesan, Subramanian
    Kar, Sidhartha S.
    Averineni, Ranjithkumar
    Shavi, Gopal
    Udupa, Nayanabhirama
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (03) : 353 - 361
  • [22] A Computational Pipeline for LC-MS/MS Based Metabolite Identification
    Zhou, Bin
    Xiao, Jun Feng
    Ressom, Habtom W.
    2011 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM 2011), 2011, : 247 - 251
  • [23] Detection of bemitil and its metabolite in urine by means of LC-MS/MS in view of doping control analysis
    Kwiatkowska, Dorota
    Kowalczyk, Katarzyna
    Grucza, Krzysztof
    Szutowski, Miroslaw
    Bulska, Ewa
    Wicka, Mariola
    DRUG TESTING AND ANALYSIS, 2018, 10 (11-12) : 1682 - 1688
  • [24] Measurement of buprenorphine in urine: immunoassay versus LC-MS/MS
    Twigger, Shirley
    Fox, Elizabeth
    Allen, Keith
    ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 339 - 339
  • [25] An LC-MS/MS analytical method for barbiturate analysis in urine
    Lee, T.
    McFarlane, J.
    CLINICAL BIOCHEMISTRY, 2011, 44 (13) : 1176 - 1176
  • [26] LC-MS/MS fast analysis of androgenic steroids in urine
    Wozniak, Barbara
    Matraszek-Zuchowska, Iwona
    Zmudzki, Jan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (10) : 2965 - 2972
  • [27] Uncertainty evaluation for the determination of creatinine in urine by LC-MS/MS
    Kim, Jin Young
    Kwon, Woonyong
    Suh, SungIll
    In, Moon Kyo
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2012, 25 (01): : 83 - 90
  • [28] A validated SPE-LC-MS/MS assay for Eplerenone and its hydrolyzed metabolite in human urine
    Zhang, JY
    Fast, DM
    Breau, AP
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (01) : 103 - 115
  • [29] A Quantitative LC-MS/MS Method for Xylazine and Metabolites in Urine
    Orahoske, Cody
    Lynch, Kara
    Halifax, John
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2024, 162 : S162 - S162
  • [30] A Dilute and Shoot LC-MS/MS Method for Antipsychotics in Urine
    Feng, Sheng
    Enders, Jeffrey R.
    Cummings, Oneka T.
    Strickland, Erin C.
    McIntire, Timothy
    McIntire, Gregory
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2020, 44 (04) : 331 - 338