Effect of sample temperature on laser-induced plasma of silicone rubber

被引:0
|
作者
An, Zhiguo [1 ,2 ]
He, Yongqi [3 ,4 ]
Chen, Qijuan [1 ]
Du, Gang [2 ]
Wang, Xilin [3 ]
机构
[1] Wuhan Univ, Sch Power & Mech Engn, Wuhan, Peoples R China
[2] Guangdong Power Grid Co Ltd, Guangzhou Power Supply Bur, Guangzhou, Peoples R China
[3] Tsinghua Univ, Tsinghua Shenzhen Int Grad Sch, Engn Lab Power Equipment Reliabil Complicated Coas, Shenzhen, Peoples R China
[4] State Grid Tianjin Elect Power Co, Chengnan Power Supply Branch, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
temperature; high-temperature vulcanized silicone rubber; laser-induced breakdown spectroscopy; aluminum hydroxide; plasma temperature; BREAKDOWN SPECTROSCOPY SYSTEM; EMISSION;
D O I
10.3389/fphy.2023.1219465
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Silicone rubber in power transmission and transformation equipment is subjected to considerable temperature changes under different application environment conditions and in different operational states. In tropical areas and the Turpan region of China, surface temperatures of silicone rubber insulators may reach or exceed 70 degrees C. During in situ testing of silicone rubber, the spectral signal may fluctuate or even be distorted when the temperature changes, and consequently, the accuracy of the analysis may be affected. Therefore, we performed a LIBS-based investigation into the dependence of the spectral signal of rubber silicone on the sample temperature. Using high-temperature vulcanized silicone rubber as the experimental material, we determined the trends in spectral line intensity for different elements, plasma temperature, and electron density with temperature when the sample temperature was increased from 25 degrees C to 310 degrees C. The results indicated that the intensities of the Al I 394.40 nm, Al I 396.15 nm, and Si I 390.55 nm lines in the LIBS spectra underwent a gradual decrease as the temperature was increased, whereas the intensity of the Al I 309.27 nm spectral line was essentially stable. However, the spectral line intensity, plasma temperature, and electron density all exhibited a spike at approximately 260 degrees C, which occurred because of the decomposition of aluminum hydroxide. The results of the present study should prove to be of significance in further increasing the accuracy of LIBS analysis as applied to silicone rubber surface monitoring in high-temperature environments.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Determination of laser-induced plasma temperature
    Shen, ZH
    Bian, BM
    Ni, XW
    Lu, J
    Zhang, SY
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2000, 25 (04) : 231 - 233
  • [22] Temperature effect on femtosecond laser-induced breakdown spectroscopy of glass sample
    Wang, Ying
    Chen, Anmin
    Jiang, Yuanfei
    Sui, Laizhi
    Wang, Xiaowei
    Zhang, Dan
    Tian, Dan
    Li, Suyu
    Jin, Mingxing
    PHYSICS OF PLASMAS, 2017, 24 (01)
  • [23] Effect of sample temperature and laser ablation angle on optical emission and acoustic signals from laser-induced zirconium plasma
    Batsaikhan, Munkhbat
    Ohba, Hironori
    Karino, Takahiro
    Akaoka, Katsuaki
    Wakaida, Ikuo
    OPTICS EXPRESS, 2024, 32 (24): : 42624 - 42638
  • [24] Detecting Fillers Content of Silicone Rubber via Laser-induced Breakdown Spectroscopy
    Lyu, Q. S.
    Huang, R. H.
    Chen, P.
    Hong, X.
    Wang, X. L.
    Jia, Z. D.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [25] Measurement of Surface Hardness of Silicone Rubber via Laser-induced Breakdown Spectroscopy
    Chen P.
    Wang X.
    Zhou W.
    Liu B.
    Lü Q.
    Jia Z.
    Wang L.
    Dianwang Jishu/Power System Technology, 2019, 43 (04): : 1315 - 1321
  • [26] Elemental analysis of RTV and HTV silicone rubber with Laser-induced Breakdown Spectroscopy
    Wang, Xilin
    Hong, Xiao
    Chen, Can
    Wang, Han
    Jia, Zhidong
    Zou, Lin
    Li, Ruihai
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 9 - 12
  • [27] Detection of Silicone Rubber Organic Content Using Laser-induced Breakdown Spectroscopy
    He Y.
    Deng Y.
    Tian L.
    Wang X.
    Jia Z.
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (04): : 1684 - 1693
  • [28] Effect of sample temperature on time-resolved laser-induced breakdown spectroscopy
    Guo, Kaimin
    Chen, Anmin
    Xu, Wanpeng
    Zhang, Dan
    Jin, Mingxing
    AIP ADVANCES, 2019, 9 (06)
  • [29] Comparison of sample temperature effect on femtosecond and nanosecond laser-induced breakdown spectroscopy
    刘淼
    陈安民
    陈雨桐
    曾祥榆
    王秋云
    张丹
    杨大鹏
    金明星
    Plasma Science and Technology, 2021, (07) : 136 - 141
  • [30] Comparison of sample temperature effect on femtosecond and nanosecond laser-induced breakdown spectroscopy
    LIU, Miao
    CHEN, Anmin
    CHEN, Yutong
    ZENG, Xiangyu
    WANG, Qiuyun
    ZHANG, Dan
    YANG, Dapeng
    JIN, Mingxing
    PLASMA SCIENCE & TECHNOLOGY, 2021, 23 (07)