Experimental investigation of the structural performance of fiber-reinforced patches in the repair of locally damaged steel pipes

被引:1
|
作者
da Silva, Daniel L. [1 ]
Echer, Leonel [2 ,3 ]
Tanzi, Boris Rojo N. [2 ]
Marczak, Rogerio J. [2 ]
Iturrioz, Ignacio [2 ]
机构
[1] PETROBRAS Petr Brasileiro SA, UPGN Rota GasLub 3, Rodovia Estadual RJ-116-Km 5,2, BR-24841203 Itaborai, RJ, Brazil
[2] Fed Univ Rio Grande, Dept Mech Engn, Rua Sarmento Leite 425, BR-90046902 Porto Alegre, RS, Brazil
[3] Inst SENAI Inovacao Engn Polimeros, ISI Polimeros, Av Pres Joao Goulart 682, BR-93030090 Sao Leopoldo, RS, Brazil
关键词
Fiber-reinforced patch; Structural repair; Acoustic emission; Hydrostatic test; COMPOSITE REPAIR; SHAPE;
D O I
10.1007/s40430-023-04348-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In the present work, we investigate the performance of fiber-reinforced patches in the repair of a locally damaged steel pipe. The specimen of the study was submitted to hydrostatic tests before damage and after repair. Damage was generated as a through-thickness cut acting diagonally to the pipe axis. The repair patch comprised twelve layers of fiberglass plain weave fabric aligned orthogonally to the pipe axis. The layers were divided into four distinct sizes and overlapped in a stepped configuration. The hydrostatic tests were conducted until the maximum admissible pressure for the undamaged steel pipe. Two piezoelectric sensors and four strain gauges were used in the pipe's instrumentation. The signal obtained during the successive tests was processed in terms of acoustic emission. The repair patch successfully survived the test scenario, and acoustic emission detected no significant events. The repair patch robustness was assessed by incrementally degrading its surface and resubmitting the repaired pipe to the hydrostatic test. The repair patch only failed after degrading half of its surface (middle and top layers). A liquid penetrant test was used to demonstrate the patch's failure (surface moisture evidencing leaking), which occurred in the borders of the through-thickness cut. Furthermore, the presence of microcracks or damage propagation in the surroundings of the substrate damage was not detected using a borescope.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Experimental and numerical investigation on flexural and fracture performance of steel fiber reinforced shotcrete
    Zhang, Zhiqiang
    Zhu, Xingyu
    Zhang, Yanyang
    Gong, Ruikai
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 315
  • [42] Experimental study on residual properties of thermally damaged steel fiber-reinforced concrete containing copper slag as fine aggregate
    Binaya Patnaik
    Chandrasekhar Bhojaraju
    Seyed Sina Mousavi
    Journal of Material Cycles and Waste Management, 2020, 22 : 801 - 815
  • [43] Fiber-Reinforced Concrete for an Innovative Energy Storage Plant: From the Experimental Investigation to the Structural Design
    Lo Monte, Francesco
    Harmon, John
    Andrade, Jose
    Ferrara, Liberato
    TRANSFORMING CONSTRUCTION: ADVANCES IN FIBER REINFORCED CONCRETE, BEFIB 2024, 2024, 54 : 252 - 259
  • [44] A review on the mechanical characteristics of thermally damaged steel and polypropylene hybrid fiber-reinforced concretes
    Fengzhen He
    Luigi Biolzi
    Valter Carvelli
    Xiaowei Feng
    Archives of Civil and Mechanical Engineering, 24
  • [45] Experimental evaluation of steel fiber effect on mechanical properties of steel fiber-reinforced cement matrix
    Jadidi A.
    Amiri M.
    Zeighami E.
    1600, Gruppo Italiano Frattura (11): : 249 - 262
  • [46] A review on the mechanical characteristics of thermally damaged steel and polypropylene hybrid fiber-reinforced concretes
    He, Fengzhen
    Biolzi, Luigi
    Carvelli, Valter
    Feng, Xiaowei
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2024, 24 (02)
  • [47] Experimental study on residual properties of thermally damaged steel fiber-reinforced concrete containing copper slag as fine aggregate
    Patnaik, Binaya
    Bhojaraju, Chandrasekhar
    Mousavi, Seyed Sina
    JOURNAL OF MATERIAL CYCLES AND WASTE MANAGEMENT, 2020, 22 (03) : 801 - 815
  • [48] Strengthening of heat-damaged steel fiber-reinforced concrete using CFRP composites: Experimental study and analytical modeling
    Nematzadeh, Mahdi
    Hasan-Nattaj, Farid
    Gholampour, Aliakbar
    Sabetifar, Hassan
    Ngo, Tuan D.
    STRUCTURES, 2021, 32 : 1856 - 1870
  • [50] Experimental investigation on flexural performance of splicing glass fiber-reinforced polymer (GFRP)-Concrete-steel sandwich composite members
    Gao, Hai-yang
    Wang, Lian-guang
    Chen, Bai-ling
    Li, Xue
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (15) : 3155 - 3170