Assessment Of the Obturation Quality of Three Different Endodontic Rotary Files Using Cbct

被引:0
|
作者
Swathi, S. [1 ]
Antony, S. Delphine Priscilla [1 ]
机构
[1] Saveetha Univ, Saveetha Dent Coll & Hosp, Dept Conservat Dent & Endodont, Saveetha Inst Med & Tech Sci, Chennai, India
关键词
C; B; T; Quality; Permanent teeth; Obturation;
D O I
10.47750/jptcp.2023.30.06.010
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: To assess the quality of obturation using three different rotary endodontic files using CBCTMaterials And Methods: 30 extracted single rooted mandibular premolars were collected. Access cavity preparation was done and working length determined. Biomechanical preparation was done using three different rotary files. Samples were divided into 3 groups and the quality of obturation was analyzed using cone beam computed tomography.Results: Profit S3 showed better obturation quality comparatively to other two file systems. Assessment of quality of obturation was statistically done using chi square test and there was a statistical significant difference between all the groups in length of obturation, quality of the obturation and density of the obturation (p=0.01). Conclusion: Among three different rotary endodontic files profit S3 has perfect obturation quality in length, density and taper next comes the Neo Endo predominantly has acceptable quality of obturation compared to protaper Gold in density, taper and length.
引用
收藏
页码:E65 / E73
页数:9
相关论文
共 50 条
  • [31] Efficacy of three different rotary files to remove gutta-percha and Resilon from root canals
    Marfisi, K.
    Mercade, M.
    Plotino, G.
    Duran-Sindreu, F.
    Bueno, R.
    Roig, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (11) : 1022 - 1028
  • [32] Root Canal Filling Quality Comparison of a Premixed Calcium Silicate Endodontic Sealer and Different Carrier-Based Obturation Systems
    Perez-Alfayate, Ruth
    Mercade, Montse
    Algar-Pinilla, Juan
    Cisneros-Cabello, Rafael
    Foschi, Federico
    Cohen, Stephen
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (06) : 1 - 10
  • [33] Effects of Chitosan, NaOCl, and EDTA Irrigation Solutions on the Cyclic Fatigue Resistance of Three Nickel-Titanium Endodontic Rotary Files: An In Vitro Study
    Salloom, Wisam S.
    Shukri, Biland M. S.
    DENTAL HYPOTHESES, 2022, 13 (04): : 121 - 123
  • [34] Crack Initiation on the Apical Root Surface Caused by Three Different Nickel-Titanium Rotary Files at Different Working Lengths
    Adorno, Carlos G.
    Yoshioka, Takatomo
    Suda, Hideaki
    JOURNAL OF ENDODONTICS, 2011, 37 (04) : 522 - 525
  • [35] Comparative Evaluation of Instrumentation Time, Obturation Time, and Radiographic Quality of Obturation Using Two Rotary Systems and Manual Technique for Primary Molar Pulpectomies - In vivo Study
    Shah, Heeral Sureshkumar
    Patil, Vishwas Mohanrao
    Kamath, Ananth P.
    Mathur, Aditi Anmol
    CONTEMPORARY CLINICAL DENTISTRY, 2021, 12 (01) : 55 - 62
  • [36] The Cyclic Fatigue Resistance of Different Lengths of CM Gold Wire and CM Blue Wire NiTi Alloy Endodontic Rotary Files: An In Vitro Study
    Faus-Matoses, Vicente
    Faus-Llacer, Vicente
    Ruiz-Sanchez, Celia
    Prats Gallego, Sofia
    Zubizarreta-Macho, Alvaro
    Solano-Mendoza, Beatriz
    Biedma, Benjamin Martin
    Faus-Matoses, Ignacio
    APPLIED SCIENCES-BASEL, 2023, 13 (07):
  • [37] Micro-computed tomography evaluation of dentinal cracks after root canal preparation with different endodontic rotary files: An ex vivo study
    Alzamanan, Mohammed Mana
    Albassam, Abdullah Abdulrahman
    Khattab, Emad Mahmoud
    Alghamdi, Faisal Turki
    DENTAL AND MEDICAL PROBLEMS, 2025, 62 (01) : 89 - 98
  • [38] Three-Dimensional Measurement of Obturation Quality of Bioceramic Materials in Filling Arti fi cial Internal Root Resorption Cavities Using Different Obturation Techniques: An In Vitro Comparative Study
    Sharki, Ammar M.
    Ali, Ahmed H.
    JOURNAL OF ENDODONTICS, 2024, 50 (07) : 997 - 1003
  • [39] Evaluation of apically extruded debris during root canal preparation in primary molar teeth using three different rotary systems and hand files
    Topcuoglu, Gamze
    Topcuoglu, Huseyin Sinan
    Akpek, Firdevs
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2016, 26 (05) : 357 - 363
  • [40] Image analysis for dental bone quality assessment using CBCT imaging
    Suprijanto
    Epsilawati, L.
    Hajarini, M. S.
    Juliastuti, E.
    Susanti, H.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694