Image quality models for 2D and 3D x-ray imaging systems: A perspective vignette

被引:1
|
作者
Siewerdsen, Jeffrey H. H. [1 ,2 ,3 ,4 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, 1400 Pressler, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Neurosurg, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Inst Data Sci Oncol, Surg Data Sci, Houston, TX 77030 USA
关键词
cascaded systems analysis; cone-beam CT; dual-energy imaging; flat-panel detectors; image quality; image reconstruction; imaging task; noise-power spectrum; spatial resolution; tomosynthesis; CONE-BEAM CT; NOISE-POWER SPECTRUM; FLAT-PANEL IMAGERS; DETECTIVE QUANTUM EFFICIENCY; SPATIAL-RESOLUTION; OPTIMIZATION; SIGNAL; PROPAGATION; PERFORMANCE; SCANNER;
D O I
10.1002/mp.16051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image quality models based on cascaded systems analysis and task-based imaging performance were an important aspect of the emergence of 2D and 3D digital x-ray systems over the last 25 years. This perspective vignette offers cursory review of such developments and personal insights that may not be obvious within previously published scientific literature. The vignette traces such models to the mid-1990s, when flat-panel x-ray detectors were emerging as a new base technology for digital radiography and benefited from the rigorous, objective characterization of imaging performance gained from such models. The connection of models for spatial resolution and noise to spatial-frequency-dependent descriptors of imaging task provided a useful framework for system optimization that helped to accelerate the development of new technologies to first clinical use. Extension of the models to new technologies and applications is also described, including dual-energy imaging, photon-counting detectors, phase contrast imaging, tomosynthesis, cone-beam CT, 3D image reconstruction, and image registration.
引用
收藏
页码:109 / 116
页数:8
相关论文
共 50 条
  • [31] Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images
    Dormer, James D.
    Bhuiyan, Md Fiaz Islam
    Rahman, Nahian
    Deaton, Nancy
    Sheng, Jun
    Padala, Muralidhar
    Desai, Jaydev P.
    Fei, Baowei
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [32] Thorax x-ray and CT interventional dataset for nonrigid 2D/3D image registration evaluation
    Xia, Wei
    Jin, Qingpeng
    Ni, Caifang
    Wang, Yanling
    Gao, Xin
    MEDICAL PHYSICS, 2018, 45 (11) : 5343 - 5351
  • [33] Calibration model of a dual gain flat panel detector for 2D and 3D x-ray imaging
    Schmidgunst, C.
    Ritter, D.
    Lang, E.
    MEDICAL PHYSICS, 2007, 34 (09) : 3649 - 3664
  • [34] Carbon speciation in organic fossils using 2D to 3D x-ray Raman multispectral imaging
    Georgiou, Rafaella
    Gueriau, Pierre
    Sahle, Christoph J.
    Bernard, Sylvain
    Mirone, Alessandro
    Garrouste, Romain
    Bergmann, Uwe
    Rueff, Jean-Pascal
    Bertrand, Loic
    SCIENCE ADVANCES, 2019, 5 (08)
  • [35] A physical breast phantom for 2D and 3D x-ray imaging made through inkjet printing
    Ikejimba, Lynda C.
    Graff, Christian G.
    Rosenthal, Shani
    Badal, Andreu
    Ghammraoui, Bahaa
    Lo, Joseph Y.
    Glick, Stephen J.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [36] Adaption of 3D Models to 2D X-Ray Images during Endovascular Abdominal Aneurysm Repair
    Toth, Daniel
    Pfister, Marcus
    Maier, Andreas
    Kowarschik, Markus
    Hornegger, Joachim
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT I, 2015, 9349 : 339 - 346
  • [37] Using 2D detectors for x-ray imaging
    Prugovecki, Stjepan
    Beckers, Detlef
    Seo, Koichi
    Gateshki, Milen
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C765 - C765
  • [38] 2D imaging by X-ray fluorescence microtomography
    Simionovici, A
    Chukalina, M
    Drakopoulos, M
    Snigireva, I
    Snigirev, A
    Schroer, C
    Lengeler, B
    Janssens, K
    Adams, F
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 539 - 544
  • [39] Semiconductor detectors for 2D X-ray imaging
    Ponpon, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (01): : 15 - 26
  • [40] 2D and 3D characterization of metal foams using X-ray tomography
    Elmoutaouakkil, A
    Salvo, L
    Maire, E
    Peix, G
    ADVANCED ENGINEERING MATERIALS, 2002, 4 (10) : 803 - 807