Conventional versus Extended Standard Addition Method: Determination of Capsaicinoids in Topical Creams by High-Performance Liquid Chromatography - Diode Array Detection (HPLC-DAD)

被引:0
|
作者
Anghel, Anca E. [1 ]
Balazs, Ibolya [2 ]
Mot, Augustin C. [3 ]
机构
[1] Babes Bolyai Univ, Fac Chem & Chem Engn, Doctoral Sch Chem, Cluj Napoca, Romania
[2] Babes Bolyai Univ, Fac Chem & Chem Engn, Arany Janos 11, Cluj Napoca 400028, Cluj Ounty, Romania
[3] Babe Bolyai Univ, Dept Chem, Cluj Napoca, Romania
关键词
Capsaicin; dihydrocapsaicin; extended standard addition; high-performance liquid chromatography; diode array detection (HPLC-DAD); topical cream; TEAR GAS WEAPONS; SOLVENT-EXTRACTION; CAPSICUM FRUITS; DIHYDROCAPSAICIN; CALIBRATIONS; OPTIMIZATION; PURIFICATION; L;
D O I
10.1080/00032719.2022.2042010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
External standard calibration is the most common approach used to calculate the unknown concentration of analytes in analytical procedures. However, this method is accurate only if the matrix can be reproduced in the standard samples or if there are no significant interferences in the sample. A well-known calibration method that was proposed especially for the analysis of samples with matrix effects is conventional standard addition method (SAM) which implies adding known and increasing quantities of the analyte to portions of the sample. Despite its benefit of constant matrix effect in the calibration standards, SAM has been frequently shown to be a suboptimal approach with flaws that include extrapolation prediction and thus wider confidence intervals and non-linearity at lower concentrations. Recently, new approaches have been proposed to overcome these shortcomings, including extension of the SAM by blank addition, a geometric alternative for interpolation, and even a new mathematical alternative. Herein, we applied an alternative to extend the SAM method, for semisolid samples with unavailable blank, by adding more samples with lower mass than the unknown in the SAM, and thus extending measurable points below the intercept. This approach was applied for capsaicinoid determination in topical creams after liquid-liquid microextraction, followed by high performance liquid chromatography with diode array detection (HPLC-DAD). Microextraction of the capsaicinoids was optimized in terms of pH, solvent type, vortexing and extraction times. The method appeared to significantly improve the precision, limit of detection, and lead to reduced bias compared to conventional SAM.
引用
收藏
页码:200 / 215
页数:16
相关论文
共 50 条
  • [21] DEVELOPMENT OF A NEW HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD WITH DIODE ARRAY DETECTOR (HPLC-DAD) FOR THE DETECTION OF CONGO RED AND METHYL ORANGE DYES FROM SYNTHETIC WATER SOLUTIONS
    Tatarus, Alina
    Simonescu, Claudia Maria
    Nechifor, Gheorghe
    Scutariu, Roxana
    Iancu, Vasile Ion
    Chiriac, Laura Florentina
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2021, 83 (04): : 85 - 94
  • [22] Quality control of cytostatic drug preparations-comparison of workflow and performance of Raman/UV and high-performance liquid chromatography coupled with diode array detection (HPLC-DAD)
    Reinders, Lars M. H.
    Klassen, Martin D.
    vom Eyser, Claudia
    Teutenberg, Thorsten
    Jaeger, Martin
    Schmidt, Torsten C.
    Tuerk, Jochen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2587 - 2596
  • [23] Determination of eumelanin and pheomelanin in melanomas using solid-phase extraction and high performance liquid chromatography-diode array detection (HPLC-DAD) analysis
    Rioux, Benjamin
    Rouanet, Jacques
    Akil, Hussein
    Besse, Sophie
    Debiton, Eric
    Bouchon, Bernadette
    Degoul, Francoise
    Quintana, Mercedes
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1113 : 60 - 68
  • [24] Evaluating four modes of extraction to analyze bioactive compounds in Garcinia brasiliensis (bacupari) by high-performance liquid chromatography diode-array detection (HPLC-DAD)
    da Silva, Claudinei A.
    Rosa, Isael A.
    de Souza, Thiago C.
    Dos Santos, Marcelo H.
    NATURAL PRODUCT RESEARCH, 2021, 35 (21) : 4073 - 4077
  • [25] Determination of stilbenes in Sicilian pistachio by high-performance liquid chromatographic diode array (HPLC-DAD/FLD) and evaluation of eventually mycotoxin contamination
    Grippi, Francesca
    Crosta, Lucia
    Aiello, Gioacchino
    Tolomeo, Manlio
    Oliveri, Francesca
    Gebbia, Nicola
    Curione, Alice
    FOOD CHEMISTRY, 2008, 107 (01) : 483 - 488
  • [26] Determination of squalene using high-performance liquid chromatography with diode array detection
    Lu, HT
    Jiang, Y
    Chen, F
    CHROMATOGRAPHIA, 2004, 59 (5-6) : 367 - 371
  • [27] Determination of Squalene Using High-Performance Liquid Chromatography with Diode Array Detection
    Hai-Tao Lu
    Yue Jiang
    Feng Chen
    Chromatographia, 2004, 59 : 367 - 371
  • [28] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) USING DIODE-ARRAY DETECTION
    MICELI, JN
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1240 - 1240
  • [29] Determination of Cr3+, CrO42-, and Cr2O72- in environmental matrixes by high-performance liquid chromatography with diode-array detection (HPLC-DAD)
    Cathum, S
    Brown, CE
    Wong, W
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) : 103 - 110
  • [30] Method development for gypenosides fingerprint by high performance liquid chromatography with diode-array detection and the addition of internal standard
    Liu, Fang
    Ren, Dequan
    Guo, De-An
    Pan, Yifeng
    Zhang, Huzhe
    Hu, Ping
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2008, 56 (03) : 389 - 393