A System Based on Photoplethysmography and Photobiomodulation for Autonomic Nervous System Measurement and Adjustment

被引:0
|
作者
Shan, Yi-Chia [1 ]
Fang, Wei [2 ]
Wu, Jih-Huah [3 ]
机构
[1] Ming Chuan Univ, Dept Informat & Telecommun Engn, 5 Deming Rd, Taoyuan 333, Taiwan
[2] Natl Taiwan Univ, Dept Biomechatron Engn, 1,Sec 4,Roosevelt Rd, Taipei 106, Taiwan
[3] Ming Chuan Univ, Dept Biomed Engn, 5 Deming Rd, Taoyuan 333, Taiwan
来源
LIFE-BASEL | 2023年 / 13卷 / 02期
关键词
autonomic nervous system; heart rate variability; photoplethysmography; photobiomodulation; HEART-RATE-VARIABILITY; ACUPUNCTURE; NEIGUAN;
D O I
10.3390/life13020564
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
(1) Background: The imbalance of the autonomic nervous system (ANS) is common worldwide. Many people have high tension when the sympathetic nervous system is hyperactive or low attention when the parasympathetic nervous system is hyperactive. To improve autonomic imbalance, a feasible and integrated system was proposed to measure and affect the ANS status. (2) Methods: The proposed system consists of a signal-processing module, an LED stimulation module, a photoplethysmography (PPG) sensor and an LCD display. The heart rate variability (HRV) and ANS status can be analyzed from PPG data. To confirm HRV analysis from PPG data, an electrocardiogram (ECG) device was also used to measure HRV. Additionally, photobiomodulation (PBM) was used to affect the ANS status, and two acupuncture points (Neiguan (PC6) and Shenmen (HT7)) were stimulated with different frequencies (10 Hz and 40 Hz) of PBM. (3) Results: Two subjects were tested with the developed system. HRV metrics were discussed in the time domain and frequency domain. HRV metrics have a similar change trend on PPG and ECG signals. In addition, the SDNN was increased, and the parasympathetic nervous system (PNS: HF (%)) was enhanced with a 10 Hz pulse rate stimulation at the Neiguan acupoint (PC6). Furthermore, the SDNN was increased, and the sympathetic nervous system (SNS: LF (%)) was enhanced with a 40 Hz pulse rate stimulation at the Shenmen (HT7) acupoint. (4) Conclusion: A prototype to measure and affect the ANS was proposed, and the functions were feasible. The test results show that stimulating the Neiguan (PC6) acupoint can inhibit the SNS. In contrast, stimulating the Shenmen (HT7) acupoint can activate the SNS. However, more experiments must be conducted to confirm the effect by choosing different pulse rates, dosages and acupoints.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Marital Conflict and Trajectories of Adolescent Adjustment: The Role of Autonomic Nervous System Coordination
    Philbrook, Lauren E.
    Erath, Stephen A.
    Hinnant, J. Benjamin
    El-Sheikh, Mona
    DEVELOPMENTAL PSYCHOLOGY, 2018, 54 (09) : 1687 - 1696
  • [32] Nociception and autonomic nervous system
    Cortelli, P.
    Giannini, G.
    Favoni, V.
    Cevoli, S.
    Pierangeli, G.
    NEUROLOGICAL SCIENCES, 2013, 34 (01) : S41 - S46
  • [33] Autonomic nervous system and hypertension
    Iscen, Sinan
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2016, 20 (02) : 201 - 201
  • [34] SURGERY OF THE AUTONOMIC NERVOUS SYSTEM
    SMITHWICK, RH
    NEW ENGLAND JOURNAL OF MEDICINE, 1947, 236 (18): : 662 - 669
  • [35] The Autonomic Nervous System and Hypertension
    Mancia, Giuseppe
    Grassi, Guido
    CIRCULATION RESEARCH, 2014, 114 (11) : 1804 - 1814
  • [36] Autonomic nervous system testing
    Flachenecker, P
    Reiners, K
    MUSCLE & NERVE, 1998, 21 (05) : 680 - 680
  • [37] Autonomic nervous system and obesity
    不详
    CLINICAL AUTONOMIC RESEARCH, 2004, 14 (06) : 353 - 354
  • [38] The Autonomic Nervous System and Emotion
    Levenson, Robert W.
    EMOTION REVIEW, 2014, 6 (02) : 100 - 112
  • [39] Autonomic nervous system and inflammation
    Jaenig, Wilfrid
    AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2014, 182 : 1 - 3
  • [40] Sleep and autonomic nervous system
    Zoccoli, Giovanna
    Amici, Roberto
    CURRENT OPINION IN PHYSIOLOGY, 2020, 15 : 128 - 133