Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction

被引:7
|
作者
Zhang, Yu [1 ]
Peng, Wanlin [1 ]
Xiao, Yi [1 ]
Ming, Yue [1 ]
Ma, Kehang [1 ]
Hu, Sixian [1 ]
Zeng, Wen [1 ]
Zeng, Lingming [1 ]
Liang, Zejun [1 ]
Zhang, Xiaoyong [2 ]
Xia, Chunchao [1 ]
Li, Zhenlin [1 ]
机构
[1] Sichuan Univ, Dept Radiol, West China Hosp, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
[2] Philips Healthcare, Clin Sci, Chengdu, Peoples R China
关键词
Deep learning; Artificial intelligence; Cholangiopancreatography; magnetic resonance; MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY; ACQUISITION TIME; IMAGE QUALITY; SPIN-ECHO; SEQUENCE; CHOLANGIOGRAPHY;
D O I
10.1007/s00330-022-09227-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To compare the image quality of three-dimensional breath-hold magnetic resonance cholangiopancreatography with deep learning-based compressed sensing reconstruction (3D DL-CS-MRCP) to those of 3D breath-hold MRCP with compressed sensing (3D CS-MRCP), 3D breath-hold MRCP with gradient and spin-echo (3D GRASE-MRCP) and conventional 2D single-shot breath-hold MRCP (2D MRCP). Methods In total, 102 consecutive patients who underwent MRCP at 3.0 T, including 2D MRCP, 3D GRASE-MRCP, 3D CS-MRCP, and 3D DL-CS-MRCP, were prospectively included. Two radiologists independently analyzed the overall image quality, background suppression, artifacts, and visualization of pancreaticobiliary ducts using a five-point scale. The signal-to-noise ratio (SNR) of the common bile duct (CBD), contrast-to-noise ratio (CNR) of the CBD and liver, and contrast ratio between the periductal tissue and CBD were measured. The Friedman test was performed to compare the four protocols. Results 3D DL-CS-MRCP resulted in improved SNR and CNR values compared with those in the other three protocols, and better contrast ratio compared with that in 3D CS-MRCP and 3D GRASE-MRCP (all, p < 0.05). Qualitative image analysis showed that 3D DL-CS-MRCP had better performance for second-level intrahepatic ducts and distal main pancreatic ducts compared with 3D CS-MRCP (all, p < 0.05). Compared with 2D MRCP, 3D DL-CS-MRCP demonstrated better performance for the second-order left intrahepatic duct but was inferior in assessing the main pancreatic duct (all, p < 0.05). Moreover, the image quality was significantly higher in 3D DL-CS-MRCP than in 3D GRASE-MRCP. Conclusion 3D DL-CS-MRCP has superior performance compared with that of 3D CS-MRCP or 3D GRASE-MRCP. Deep learning reconstruction also provides a comparable image quality but with inferior main pancreatic duct compared with that revealed by 2D MRCP.
引用
收藏
页码:2500 / 2509
页数:10
相关论文
共 50 条
  • [21] Single breath-hold 3D measurement of left atrial volume using compressed sensing cardiovascular magnetic resonance and a non-model-based reconstruction approach
    Orestis Vardoulis
    Pierre Monney
    Amit Bermano
    Amir Vaxman
    Craig Gotsman
    Janine Schwitter
    Matthias Stuber
    Nikolaos Stergiopulos
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 17
  • [22] Compressed sensing to reduce breath-hold duration in 19F-MR ventilation imaging
    Pippard, Benjamin
    Neal, Mary
    Maunder, Adam
    Simpson, A. John
    Hollingsworth, Kieren
    Wild, Jim
    Thelwall, Pete
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [23] Dual-contrast single breath-hold 3D abdominal MR imaging
    Winkelmann, Richard
    Boernert, Peter
    De Becker, Jan
    Hoogeveen, Romhild
    Mazurkewitz, Peter
    Doessel, Olaf
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (06) : 297 - 304
  • [24] MR cholangiopancreatography: Comparison of a breath-hold 2D projection technique with diagnostic ERCP
    Lomas, DJ
    Bearcroft, PW
    Gimson, AE
    RADIOLOGY, 1997, 205 : 1527 - 1527
  • [25] Dual-contrast single breath-hold 3D abdominal MR imaging
    Richard Winkelmann
    Peter Börnert
    Jan De Becker
    Romhild Hoogeveen
    Peter Mazurkewitz
    Olaf Dössel
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 297 - 304
  • [26] MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP
    Lomas, DJ
    Bearcroft, PWP
    Gimson, AE
    EUROPEAN RADIOLOGY, 1999, 9 (07) : 1411 - 1417
  • [27] MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP
    D. J. Lomas
    P. W. P. Bearcroft
    A. E. Gimson
    European Radiology, 1999, 9 : 1411 - 1417
  • [28] Optimization of contrast material administration for breath-hold 3D MR angiography of the abdominal vessels
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, EH
    RADIOLOGY, 1997, 205 : 673 - 673
  • [29] Single breath-hold 3D LGE using stack of spiral trajectory
    Yang Yang
    Peter Shaw
    Jorge A Gonzalez
    Christopher M Kramer
    Michael Salerno
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [30] Diagnostic accuracy of 3D breath-hold MR cholangiography using compressed sensing acceleration in visualizing non-dilated biliary system in living donor liver transplantation donors
    Ono, Ayako
    Arizono, Shigeki
    Kohno, Shigeshi
    Nakai, Hirotsugu
    Isoda, Hiroyoshi
    Kuehn, Bernd
    Togashi, Kaori
    ACTA RADIOLOGICA, 2019, 60 (10) : 1209 - 1215