Adverse events of self-expandable metal stent placement for malignant distal biliary obstruction: a large multicenter study

被引:7
|
作者
Tamura, Takashi [1 ]
Yamai, Takuo [2 ]
Uza, Norimitsu [3 ]
Yamasaki, Tomoaki [4 ]
Masuda, Atsuhiro [5 ]
Tomooka, Fumimasa [6 ]
Maruyama, Hirotsugu [7 ]
Shigekawa, Minoru [8 ]
Ogura, Takeshi [9 ]
Kuriyama, Katsutoshi [10 ]
Asada, Masanori [11 ]
Matsumoto, Hisakazu [12 ]
Takenaka, Mamoru [13 ]
Mandai, Koichiro [14 ]
Osaki, Yui [15 ]
Matsumoto, Kengo [16 ]
Sanuki, Tsuyoshi [17 ]
Shiomi, Hideyuki [18 ]
Yamagata, Yosuke [19 ]
Doi, Toshifumi [20 ]
Inatomi, Osamu [21 ]
Nakanishi, Fumihiko [22 ]
Emori, Tomoya [23 ]
Shimatani, Masaaki [24 ]
Asai, Satoshi [25 ]
Fujigaki, Seiji [26 ]
Shimokawa, Toshio [27 ]
Kitano, Masayuki [1 ,28 ]
机构
[1] Wakayama Med Univ, Dept Internal Med 2, Wakayama, Japan
[2] Osaka Int Canc Inst, Dept Hepatobiliary & Pancreat Oncol, Osaka, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Gastroenterol & Hepatol, Kyoto, Japan
[4] Osaka City Gen Hosp, Dept Gastroenterol, Osaka, Japan
[5] Kobe Univ, Dept Internal Med, Grad Sch Med, Div Gastroenterol, Hyogo, Japan
[6] Nara Med Univ, Dept Gastroenterol, Nara, Japan
[7] Osaka Metropolitan Univ, Dept Gastroenterol, Grad Sch Med, Osaka, Japan
[8] Osaka Univ, Dept Gastroenterol & Hepatol, Grad Sch Med, Osaka, Japan
[9] Osaka Med & Pharmaceut Univ Hosp, Endoscop Ctr, Osaka, Japan
[10] Kitano Hosp, PIIF Tazuke Kofukai, Dept Gastroenterol & Hepatol, Med Res Inst, Osaka, Japan
[11] Japanese Red Cross Osaka Hosp, Dept Gastroenterol & Hepatol, Osaka, Japan
[12] Japanese Red Cross Wakayama Med Ctr, Gastroenterol & Hepatol, Wakayama, Japan
[13] Kindai Univ, Dept Gastroenterol & Hepatol, Fac Med, Osaka, Japan
[14] Kyoto Second Red Cross Hosp, Dept Gastroenterol, Kyoto, Japan
[15] Nara Prefecture Seiwa Med Ctr, Dept Gastroenterol, Nara, Japan
[16] Toyonaka City Hosp, Dept Gastroenterol, Toyonaka, Osaka, Japan
[17] Kita harima Med Ctr, Dept Gastroenterol, Hyogo, Japan
[18] Hyogo Med Univ, Dept Internal Med, Div Gastroenterol & Hepatobiliary & Pancreat Dis, Nishinomiya, Hyogo, Japan
[19] Yodogawa Christians Hosp, Dept Gastroenterol & Hepatol, Osaka, Japan
[20] Kyoto Prefectural Univ Med, Grad Sch Med Sci, Mol Gastroenterol & Hepatol, Kamigyo ku, Kyoto, Japan
[21] Shiga Univ Med Sci, Dept Med, Div Gastroenterol, Otsu, Shiga, Japan
[22] Natl Hosp Org Osaka, Minami Med Ctr, Dept Gastroenterol, Kawachi Nagano, Osaka, Japan
[23] Wakayama Rosai Hosp, Dept Gastroenterol, Wakayama, Japan
[24] Kansai Med Univ, Div Gastroenterol & Hepatol, Med Ctr, Moriguchi, Osaka, Japan
[25] Tane Gen Hosp, Dept Gastroenterol, Osaka, Japan
[26] Steel Mem Hirohata Hosp, Dept Gastroenterol, Himeji, Hyogo, Japan
[27] Wakayama Med Univ Hosp, Clin Study Support Ctr, Wakayama, Japan
[28] Wakayama Med Univ, Dept Internal Med 2, 811-1 Kimiidera, Wakayama, Wakayama 6418509, Japan
关键词
RETROGRADE CHOLANGIOPANCREATOGRAPHY PANCREATITIS; RISK-FACTORS; ENDOSCOPIC SPHINCTEROTOMY; CHOLECYSTITIS; ERCP; COMPLICATIONS; PREVENTION; MIGRATION; INSERTION; EFFICACY;
D O I
10.1016/j.gie.2023.08.004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Endoscopic placement of self -expandable metal stents (SEMSs) for malignant distal biliary obstruction (MDBO) may be accompanied by several types of adverse events. The present study analyzed the adverse events occurring after SEMS placement for MDBO. Methods: The present study retrospectively investigated the incidence and types of adverse events in patients who underwent SEMS placement for MDBO between April 2018 and March 2021 at 26 hospitals. Risk factors for acute pancreatitis, cholecystitis, and recurrent biliary obstruction (RBO) were evaluated by univariate and multivariate analyses. Results: Of the 1425 patients implanted with SEMSs for MDBO, 228 (16.0%) and 393 (27.6%) experienced early adverse events and RBO, respectively. Pancreatic duct without tumor involvement (P = .023), intact papilla (P = .025), and SEMS placement across the papilla (P = .037) were independent risk factors for acute pancreatitis. Tumor involvement in the orifice of the cystic duct was an independent risk factor for cholecystitis (P < .001). Use of fully and partially covered SEMSs was an independent risk factor for food impaction and/or sludge. Use of fully covered SEMSs was an independent risk factor for stent migration. Use of uncovered SEMSs and lasercut SEMSs was an independent risk factor for tumor ingrowth. Conclusions: Pancreatic duct without tumor involvement, intact papilla, and SEMS placement across the papilla were independent risk factors for acute pancreatitis, and tumor involvement in the orifice of the cystic duct was an independent risk factor for cholecystitis. The risk factors for food impaction and/or sludge, stent migration, and tumor ingrowth differed among types of SEMSs.
引用
收藏
页码:61 / 72.e8
页数:20
相关论文
共 50 条
  • [31] Nitinol versus steel partially covered self-expandable metal stent for malignant distal biliary obstruction: a randomized trial
    Soderlund, Claes
    Linder, Stefan
    Bergenzaun, Per E.
    Grape, Tomas
    Hakansson, Hans-Olof
    Kilander, Anders
    Lindell, Gert
    Ljungman, Martin
    Ohlin, Bo
    Nielsen, Jorgen
    Rudberg, Claes
    Stotzer, Per-Ove
    Svartholm, Erik
    Toth, Ervin
    Frozanpor, Farshad
    ENDOSCOPY, 2014, 46 (11) : 941 - 948
  • [32] Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction
    Inoue, Tadahisa
    Naitoh, Itaru
    Okumura, Fumihiro
    Ozeki, Takanori
    Anbe, Kaiki
    Iwasaki, Hiroyasu
    Nishie, Hirotada
    Mizushima, Takashi
    Sano, Hitoshi
    Nakazawa, Takahiro
    Yoneda, Masashi
    Joh, Takashi
    DIGESTIVE ENDOSCOPY, 2016, 28 (07) : 731 - 737
  • [33] Self-expandable metal stent placement for the palliation of malignant gastroduodenal obstruction: experience in a large, single, UK centre
    Lowe, A. S.
    Beckett, C. G.
    Jowett, S.
    May, J.
    Stephenson, S.
    Scally, A.
    Tam, E.
    Kay, C. L.
    CLINICAL RADIOLOGY, 2007, 62 (08) : 738 - 744
  • [34] Covered self-expandable metallic stents for distal malignant biliary obstruction
    Tsujino, Takeshi
    Isayama, Hiroyuki
    Togawa, Osamu
    Nakai, Yousuke
    Omata, Masao
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2007, 22 : A84 - A84
  • [35] Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction
    Okuno, Mitsuru
    Mukai, Tsuyoshi
    Iwashita, Takuji
    Ichikawa, Hironao
    Iwasa, Yuhei
    Mita, Naoki
    Yoshida, Kensaku
    Iwata, Keisuke
    Tomita, Eiichi
    Shimizu, Masahito
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2019, 26 (06) : 211 - 218
  • [36] Effect of ursodeoxycholic acid after self-expandable metal stent placement in malignant distal biliary obstruction: a propensity score-matched cohort analysis
    Okuno, Mitsuru
    Iwata, Keisuke
    Mukai, Tsuyoshi
    Ohashi, Yosuke
    Iwata, Shota
    Iwasa, Yuhei
    Yoshida, Kensaku
    Maruta, Akinori
    Tezuka, Ryuichi
    Ichikawa, Hironao
    Mita, Naoki
    Uemura, Shinya
    Iwashita, Takuji
    Tomita, Eiichi
    Shimizu, Masahito
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (04) : 713 - +
  • [37] SEMS and Sensibility: Self-Expandable Metal Stents for Malignant Biliary Obstruction—Are Stent Characteristics Important?
    Evangelos Kalaitzakis
    Digestive Diseases and Sciences, 2019, 64 : 2376 - 2378
  • [38] The safety and efficacy of self-expandable metallic stent placement for malignant biliary obstruction with surgically altered anatomy
    Takeda, Tsuyoshi
    Sasaki, Takashi
    Mie, Takafumi
    Furukawa, Takaaki
    Kanata, Ryo
    Kasuga, Akiyoshi
    Matsuyama, Masato
    Ozaka, Masato
    Sasahira, Naoki
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2021, 56 (01) : 94 - 102
  • [39] Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: a multicenter study
    Hori, Yasuki
    Naitoh, Itaru
    Hayashi, Kazuki
    Ban, Tesshin
    Natsume, Makoto
    Okumura, Fumihiro
    Nakazawa, Takahiro
    Takada, Hiroki
    Hirano, Atsuyuki
    Jinno, Naruomi
    Togawa, Shozo
    Ando, Tomoaki
    Kataoka, Hiromi
    Joh, Takashi
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (02) : 340 - +
  • [40] Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction
    Kim, Ji Won
    Jeong, Ji Bong
    Lee, Kook Lae
    Kim, Byeong Gwan
    Ahn, Dong Won
    Lee, Jae Kyung
    Kim, Su Hwan
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (05) : 1580 - 1587