Adverse events of self-expandable metal stent placement for malignant distal biliary obstruction: a large multicenter study

被引:7
|
作者
Tamura, Takashi [1 ]
Yamai, Takuo [2 ]
Uza, Norimitsu [3 ]
Yamasaki, Tomoaki [4 ]
Masuda, Atsuhiro [5 ]
Tomooka, Fumimasa [6 ]
Maruyama, Hirotsugu [7 ]
Shigekawa, Minoru [8 ]
Ogura, Takeshi [9 ]
Kuriyama, Katsutoshi [10 ]
Asada, Masanori [11 ]
Matsumoto, Hisakazu [12 ]
Takenaka, Mamoru [13 ]
Mandai, Koichiro [14 ]
Osaki, Yui [15 ]
Matsumoto, Kengo [16 ]
Sanuki, Tsuyoshi [17 ]
Shiomi, Hideyuki [18 ]
Yamagata, Yosuke [19 ]
Doi, Toshifumi [20 ]
Inatomi, Osamu [21 ]
Nakanishi, Fumihiko [22 ]
Emori, Tomoya [23 ]
Shimatani, Masaaki [24 ]
Asai, Satoshi [25 ]
Fujigaki, Seiji [26 ]
Shimokawa, Toshio [27 ]
Kitano, Masayuki [1 ,28 ]
机构
[1] Wakayama Med Univ, Dept Internal Med 2, Wakayama, Japan
[2] Osaka Int Canc Inst, Dept Hepatobiliary & Pancreat Oncol, Osaka, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Gastroenterol & Hepatol, Kyoto, Japan
[4] Osaka City Gen Hosp, Dept Gastroenterol, Osaka, Japan
[5] Kobe Univ, Dept Internal Med, Grad Sch Med, Div Gastroenterol, Hyogo, Japan
[6] Nara Med Univ, Dept Gastroenterol, Nara, Japan
[7] Osaka Metropolitan Univ, Dept Gastroenterol, Grad Sch Med, Osaka, Japan
[8] Osaka Univ, Dept Gastroenterol & Hepatol, Grad Sch Med, Osaka, Japan
[9] Osaka Med & Pharmaceut Univ Hosp, Endoscop Ctr, Osaka, Japan
[10] Kitano Hosp, PIIF Tazuke Kofukai, Dept Gastroenterol & Hepatol, Med Res Inst, Osaka, Japan
[11] Japanese Red Cross Osaka Hosp, Dept Gastroenterol & Hepatol, Osaka, Japan
[12] Japanese Red Cross Wakayama Med Ctr, Gastroenterol & Hepatol, Wakayama, Japan
[13] Kindai Univ, Dept Gastroenterol & Hepatol, Fac Med, Osaka, Japan
[14] Kyoto Second Red Cross Hosp, Dept Gastroenterol, Kyoto, Japan
[15] Nara Prefecture Seiwa Med Ctr, Dept Gastroenterol, Nara, Japan
[16] Toyonaka City Hosp, Dept Gastroenterol, Toyonaka, Osaka, Japan
[17] Kita harima Med Ctr, Dept Gastroenterol, Hyogo, Japan
[18] Hyogo Med Univ, Dept Internal Med, Div Gastroenterol & Hepatobiliary & Pancreat Dis, Nishinomiya, Hyogo, Japan
[19] Yodogawa Christians Hosp, Dept Gastroenterol & Hepatol, Osaka, Japan
[20] Kyoto Prefectural Univ Med, Grad Sch Med Sci, Mol Gastroenterol & Hepatol, Kamigyo ku, Kyoto, Japan
[21] Shiga Univ Med Sci, Dept Med, Div Gastroenterol, Otsu, Shiga, Japan
[22] Natl Hosp Org Osaka, Minami Med Ctr, Dept Gastroenterol, Kawachi Nagano, Osaka, Japan
[23] Wakayama Rosai Hosp, Dept Gastroenterol, Wakayama, Japan
[24] Kansai Med Univ, Div Gastroenterol & Hepatol, Med Ctr, Moriguchi, Osaka, Japan
[25] Tane Gen Hosp, Dept Gastroenterol, Osaka, Japan
[26] Steel Mem Hirohata Hosp, Dept Gastroenterol, Himeji, Hyogo, Japan
[27] Wakayama Med Univ Hosp, Clin Study Support Ctr, Wakayama, Japan
[28] Wakayama Med Univ, Dept Internal Med 2, 811-1 Kimiidera, Wakayama, Wakayama 6418509, Japan
关键词
RETROGRADE CHOLANGIOPANCREATOGRAPHY PANCREATITIS; RISK-FACTORS; ENDOSCOPIC SPHINCTEROTOMY; CHOLECYSTITIS; ERCP; COMPLICATIONS; PREVENTION; MIGRATION; INSERTION; EFFICACY;
D O I
10.1016/j.gie.2023.08.004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Endoscopic placement of self -expandable metal stents (SEMSs) for malignant distal biliary obstruction (MDBO) may be accompanied by several types of adverse events. The present study analyzed the adverse events occurring after SEMS placement for MDBO. Methods: The present study retrospectively investigated the incidence and types of adverse events in patients who underwent SEMS placement for MDBO between April 2018 and March 2021 at 26 hospitals. Risk factors for acute pancreatitis, cholecystitis, and recurrent biliary obstruction (RBO) were evaluated by univariate and multivariate analyses. Results: Of the 1425 patients implanted with SEMSs for MDBO, 228 (16.0%) and 393 (27.6%) experienced early adverse events and RBO, respectively. Pancreatic duct without tumor involvement (P = .023), intact papilla (P = .025), and SEMS placement across the papilla (P = .037) were independent risk factors for acute pancreatitis. Tumor involvement in the orifice of the cystic duct was an independent risk factor for cholecystitis (P < .001). Use of fully and partially covered SEMSs was an independent risk factor for food impaction and/or sludge. Use of fully covered SEMSs was an independent risk factor for stent migration. Use of uncovered SEMSs and lasercut SEMSs was an independent risk factor for tumor ingrowth. Conclusions: Pancreatic duct without tumor involvement, intact papilla, and SEMS placement across the papilla were independent risk factors for acute pancreatitis, and tumor involvement in the orifice of the cystic duct was an independent risk factor for cholecystitis. The risk factors for food impaction and/or sludge, stent migration, and tumor ingrowth differed among types of SEMSs.
引用
收藏
页码:61 / 72.e8
页数:20
相关论文
共 50 条
  • [1] ADVERSE EVENTS OF SELF-EXPANDABLE METAL STENT PLACEMENT FOR MALIGNANT DISTAL BILIARY OBSTRUCTION CAUSED BY PANCREATIC CANCER: A LARGE MULTICENTER STUDY
    Tamura, Takashi
    Yamai, Takuo
    Uza, Norimitsu
    Yamasaki, Tomoaki
    Masuda, Atsuhiro
    Maruyama, Hirotsugu
    Shigekawa, Minoru
    Ogura, Takeshi
    Kuriyama, Katsutoshi
    Asada, Masanori
    Matsumoto, Hisakazu
    Takenaka, Mamoru
    Mandai, Koichiro
    Osaki, Yui
    Matsumoto, Kengo
    Sanuki, Tsuyoshi
    Shiomi, Hideyuki
    Yamagata, Yosuke
    Doi, Toshifumi
    Inatomi, Osamu
    Emori, Tomoya
    Nakanishi, Fumihiko
    Shimatani, Masaaki
    Asai, Satoshi
    Fujigaki, Seji
    Kitano, Masayuki
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB679 - AB681
  • [2] Double bare self-expandable metal stent for distal malignant biliary obstruction
    Li, Jia-Su
    Liu, Feng
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (03) : 603 - 603
  • [3] Self-expandable metal stent placement for malignant duodenal obstruction distal to the bulb
    Chiu, Keith Wan Hang
    Razack, Abdul
    Maraveyas, Anthony
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2015, 27 (12) : 1466 - 1472
  • [4] Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
    Zhang, Jin-Xing
    Zu, Qing-Quan
    Liu, Sheng
    Zhou, Chun-Gao
    Xia, Jin-Guo
    Shi, Hai-Bin
    SAUDI JOURNAL OF GASTROENTEROLOGY, 2018, 24 (02): : 82 - 86
  • [5] A RETROSPECTIVE MULTICENTER STUDY OF A SIDE-BY-SIDE PLASTIC STENT TO A FULLY COVERED SELF-EXPANDABLE METAL STENT IN DISTAL MALIGNANT BILIARY OBSTRUCTION
    Chun, Jung Won
    Park, Jae Ok
    Lee, Sang Hyub
    Woo, Sang Myung
    Lee, Woo Jin
    Huh, Gunn
    Paik, Woo Hyun
    Ryu, Ji Kon
    Kim, Yong-Tae
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB362 - AB362
  • [6] THE EFFICACY OF SELF-EXPANDABLE METALLIC STENT PLACEMENT ABOVE THE PAPILLA IN THE PATIENTS WITH DISTAL MALIGNANT BILIARY OBSTRUCTION
    Takada, Ryoji
    Ikezawa, Kenji
    Kiyota, Ryosuke
    Toshihiro, Imai
    Yutaro, Abe
    Fukutake, Nobuyasu
    Takatoshi, Nawa
    Ashida, Reiko
    Katayama, Kazuhiro
    Ohkawa, Kazuyoshi
    GASTROINTESTINAL ENDOSCOPY, 2019, 89 (06) : AB212 - AB212
  • [7] Experience in self-expandable metal stent in palliation of malignant biliary obstruction
    Musngi, Joseph Kelvy
    Khow, Jo-Ann
    Co-Soriano, Julius
    Ong, Evan
    Lim, Chen Pen
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2006, 21 : A440 - A440
  • [8] MANAGEMENT OF SELF-EXPANDABLE METAL STENT OBSTRUCTION IN THE TREATMENT OF DISTAL MALIGNANT BILIARY STRICTURES: A RETROSPECTIVE COHORT STUDY
    Ghazi, Rabih
    AbiMansour, Jad P.
    Law, Ryan
    Martin, John A.
    Mahmoud, Tala
    Storm, Andrew C.
    Abu Dayyeh, Barham K.
    Levy, Michael J.
    Vargas, Eric J.
    Petersen, Bret T.
    Chandrasekhara, Vinay
    GASTROINTESTINAL ENDOSCOPY, 2022, 95 (06) : AB320 - AB320
  • [9] One- and two-step self-expandable metal stent placement for distal malignant biliary obstruction: a propensity analysis
    Hamada, Tsuyoshi
    Nakai, Yousuke
    Isayama, Hiroyuki
    Togawa, Osamu
    Kogure, Hirofumi
    Kawakubo, Kazumichi
    Tsujino, Takeshi
    Sasahira, Naoki
    Hirano, Kenji
    Yamamoto, Natsuyo
    Ito, Yukiko
    Sasaki, Takashi
    Mizuno, Suguru
    Toda, Nobuo
    Tada, Minoru
    Koike, Kazuhiko
    JOURNAL OF GASTROENTEROLOGY, 2012, 47 (11) : 1248 - 1256
  • [10] One- and two-step self-expandable metal stent placement for distal malignant biliary obstruction: a propensity analysis
    Tsuyoshi Hamada
    Yousuke Nakai
    Hiroyuki Isayama
    Osamu Togawa
    Hirofumi Kogure
    Kazumichi Kawakubo
    Takeshi Tsujino
    Naoki Sasahira
    Kenji Hirano
    Natsuyo Yamamoto
    Yukiko Ito
    Takashi Sasaki
    Suguru Mizuno
    Nobuo Toda
    Minoru Tada
    Kazuhiko Koike
    Journal of Gastroenterology, 2012, 47 : 1248 - 1256