Comparison of Two Printed Pseudoisochromatic Tests for Color Vision Assessment

被引:0
|
作者
Alduhayan, Reema [1 ,2 ]
Almustanyir, Ali [1 ]
机构
[1] King Saud Univ, Coll Appl Med Sci, Dept Optometry, Riyadh, Saudi Arabia
[2] King Saud Bin Abdulaziz Univ Hlth Sci, King Abdullah Int Med Res Ctr, Imaging Res Dept, Riyadh, Saudi Arabia
关键词
ISHIHARA; PLATES; SENSITIVITY; DEFICIENCY;
D O I
10.1097/OPX.0000000000002087
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCEThe Waggoner PIP24 is a pseudoisochromatic test with a pattern similar to the Ishihara test. This study determined that the W-PIP24 can be used clinically to yield screening results (or sensitivity and specificity) comparable with the Ishihara.PURPOSEThis study aimed to determine whether the W-PIP24 is equivalent to the Ishihara 38 edition pseudoisochromatic test in detecting red-green color vision defects. Also, the performance of each plate of the W-PIP24 in detecting the color vision defects relative to the Ishihara test was determined.METHODSSixty-three individuals with congenital red-green color vision defects and 57 with normal trichromacy were recruited. Participants were tested with both the Ishihara and W-PIP24. The first-order agreement coefficients were calculated for the Ishihara and W-PIP24. The results were also analyzed using specificity, sensitivity, efficiency, and predictive pass and fail values.RESULTSThe agreement between the W-PIP24 and Ishihara test using the recommended criterion of using all plates was perfect. The sensitivity, specificity, predictive pass, and predictive fail were 1.00 (95% confidence interval, 0.94 to 1.00).CONCLUSIONSThis study showed that the W-PIP24 using a failure criterion of three or more errors on screening plates 1 to 15 is equivalent to the Ishihara test while screening for red-green color vision deficiency using a failure criterion of three or more errors on screening plates 1 to 17 of the Ishihara 38 edition.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 50 条
  • [31] COLOR-VISION TESTS AND COLOR-VISION ADVICE/E
    BIRCH, J
    BRITISH JOURNAL OF PHYSIOLOGICAL OPTICS, 1974, 29 (01): : 1 - 29
  • [32] The Spectral Pseudoisochromatic Images for Testing Retinal Cone Spectral Responses of Observers with Normal Color Vision
    He Rui-li
    Huang Min
    Guo Chun-li
    Xi Yong-hui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (08) : 2454 - 2461
  • [33] Comparison of a multispectral vision system and a colorimeter for the assessment of meat color
    Trinderup, Camilla H.
    Dahl, Anders
    Jensen, Kirsten
    Carstensen, Jens Michael
    Conradsen, Knut
    MEAT SCIENCE, 2015, 102 : 1 - 7
  • [34] The Change in Color Vision with Normal Aging Evaluated on Standard Pseudoisochromatic Plates Part-3
    Ichikawa, Kazuo
    Yokoyama, Sho
    Tanaka, Yoshiki
    Nakamura, Hideki
    Smith, R. Theodore
    Tanabe, Shoko
    CURRENT EYE RESEARCH, 2021, 46 (07) : 1038 - 1046
  • [35] Colorimetric analysis and performance assessment of the Hahn New Pseudoisochromatic Colour Vision Test
    Dain, SJ
    Gray, S
    Tran, L
    COLOR RESEARCH AND APPLICATION, 1998, 23 (02): : 69 - 77
  • [36] Relationship between pseudoisochromatic plates and cone contrast thresholding to evaluate red and green color vision
    Akbarpour, Meleeka
    Vu, Anderson Nguyen
    Duong, Amber
    Wang, Jessica
    Ahn, Minnah
    Patel, Vivek
    Ediriwickrema, Lilangi S.
    Crow, Robert
    To, Josiah K.
    Browne, Andrew
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [37] Color vision testing in patients with acquired color deficiency and low-vision. Results of two oversized hue discrimination tests
    Schroeder, BU
    Otto, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S429 - S429
  • [38] Assessment of #TheDress With Traditional Color Vision Tests: Perception Differences Are Associated With Blueness
    Feitosa-Santana, Claudia
    Lutze, Margaret
    Barrionuevo, Pablo A.
    Cao, Dingcai
    I-PERCEPTION, 2018, 9 (02):
  • [39] Comparison of the D-15 and City University (second) color vision tests
    Oliphant, D
    Hovis, JK
    VISION RESEARCH, 1998, 38 (21) : 3461 - 3465