摘要
Precision and traceable measurement of small forces have become increasingly important due to the rapid change in technology and miniaturization of devices. In this paper, we have discussed the design, development and metrological aspects of double bending beam force transducer for low-force measurements. To achieve this task, elastic spring element is designed and machined for fabricating the force transducer and virtually tested through the finite element analysis (FEA) method to validate its load capacity and to understand its mechanical behaviour. The metrological capability of spring element is determined with the application of small forces, sensing the applied forces through contact and non-contact methods. In the contact method, strain gauges are employed for the detection of induced strain on the spring element. For this, the maximum and minimum strain values and their distribution are found to get the optimum normalized output in the electrical unit of mV/V. In the non-contact method, a pair of light-emitting diode (LED) and light-dependent resistor (LDR) is utilized for the detection of the bending caused by the applied force. The optimal detectable deflection is found in the spring element through FEA. The experimental characterization results of the force transducers showed that the developed force transducers have good metrological capability in terms of high linearity and repeatability in the range of 0.3-3 N.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [41] LIMITS OF HIGH-DENSITY, LOW-FORCE PRESSURE CONTACTS
    BEALE, J
    PEASE, RF
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1994, 17 (02): : 257 - 262
  • [42] The low-force frictional characteristics of fabrics against engineering surfaces
    Taylor, PM
    Pollet, DM
    JOURNAL OF THE TEXTILE INSTITUTE, 2000, 91 (01) : 1 - 15
  • [43] Exact low-force kinetics from high-force single-molecule unfolding events
    Nummela, Jeremiah
    Andricioaei, Ioan
    BIOPHYSICAL JOURNAL, 2007, 93 (10) : 3373 - 3381
  • [44] Low-force spectroscopy on graphene membranes by scanning tunneling microscopy
    Uder, Bernd
    Gao, Haibin
    Kunnas, Peter
    de Jonge, Niels
    Hartmann, Uwe
    NANOSCALE, 2018, 10 (04) : 2148 - 2153
  • [45] INVESTIGATION OF LOW-FORCE HIGH-FREQUENCY ACTIVITIES ON THE DEVELOPMENT OF CARPAL-TUNNEL SYNDROME
    SMUTZ, WP
    MILLER, SC
    EATON, CJ
    BLOSWICK, DS
    FRANCE, EP
    CLINICAL BIOMECHANICS, 1994, 9 (01) : 15 - 20
  • [46] Combined magnetoelastic transducer for torque and force measurement
    Zakrzewski, J
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (04) : 807 - 810
  • [47] A new magnetoelastic transducer for torque and force measurement
    Zakrzewski, J
    JOINT CONFERENCE - 1996: IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE & IMEKO TECHNICAL COMMITTEE 7, CONFERENCE PROCEEDINGS, VOLS I AND II: QUALITY MEASUREMENTS: THE INDISPENSABLE BRIDGE BETWEEN THEORY AND REALITY (NO MEASUREMENTS? NO SCIENCE!), 1996, : 497 - 501
  • [48] Axial and bending force measurement system based on double current supplied bridge
    Idzkowski, A
    Makal, J
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS IV, 2006, 6159
  • [49] Papillary Muscle Force Transducer for Measurement In Vivo
    Askov J.B.
    Honge J.L.
    Nygaard H.
    Hasenkam J.M.
    Nielsen S.L.
    Jensen M.O.
    Cardiovascular Engineering and Technology, 2011, 2 (3) : 196 - 202
  • [50] Measurement of steep impulse response of a force transducer
    Fujii, Y
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (01) : 65 - 69