Screw Osteointegration-Increasing Biomechanical Resistance to Pull-Out Effect

被引:1
|
作者
Costachescu, Bogdan [1 ,2 ]
Niculescu, Adelina-Gabriela [3 ,4 ]
Grumezescu, Alexandru Mihai [3 ,4 ,5 ]
Teleanu, Daniel Mihai [6 ]
机构
[1] Gr T Popa Univ Med & Pharm, Iasi 700115, Romania
[2] Prof Dr N Oblu Emergency Clin Hosp, Iasi 700309, Romania
[3] Univ Bucharest, Univ Bucharest ICUB, Res Inst, Bucharest 050657, Romania
[4] Politehn Univ Bucuresti, Dept Sci & Engn Oxide Mat & Nanomat, Bucharest 011061, Romania
[5] Acad Romanian Scientists, Ilfov 3, Bucharest 050044, Romania
[6] Carol Davila Univ Med & Pharm, Bucharest 050474, Romania
关键词
bone fixation; spinal fixation devices; spinal screws; pull-out effect; reinforcement strategies; osteointegration; material optimization; ANTERIOR CERVICAL DISKECTOMY; SPINAL PEDICLE SCREWS; STRENGTH; FIXATION; FUSION; RODS; AUGMENTATION; INSTRUMENTATION; HYDROXYAPATITE; MANAGEMENT;
D O I
10.3390/ma16165582
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Spinal disorders cover a broad spectrum of pathologies and are among the most prevalent medical conditions. The management of these health issues was noted to be increasingly based on surgical interventions. Spinal fixation devices are often employed to improve surgery outcomes, increasing spinal stability, restoring structural integrity, and ensuring functionality. However, most of the currently used fixation tools are fabricated from materials with very different mechanical properties to native bone that are prone to pull-out effects or fail over time, requiring revision procedures. Solutions to these problems presently exploited in practice include the optimal selection of screw shape and size, modification of insertion trajectory, and utilization of bone cement to reinforce fixation constructs. Nevertheless, none of these methods are without risks and limitations. An alternative option to increasing biomechanical resistance to the pull-out effect is to tackle bone regenerative capacity and focus on screw osteointegration properties. Osteointegration was reportedly enhanced through various optimization strategies, including use of novel materials, surface modification techniques (e.g., application of coatings and topological optimization), and utilization of composites that allow synergistic effects between constituents. In this context, this paper takes a comprehensive path, starting with a brief presentation of spinal fixation devices, moving further to observations on how the pull-out strength can be enhanced with existing methods, and further focusing on techniques for implant osteointegration improvement.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Biomechanical Comparison of Pull-out Strength of Different Cementation and Pedicle Screw Placement Techniques in a Calf Spine Model
    Akgul, Turgut
    Korkmaz, Murat
    Pehlivanoglu, Tuna
    Bayram, Serkan
    Ozdemir, Mustafa Abdullah
    Karalar, Sahin
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (SUPPL 1) : 134 - 140
  • [22] Restoration of pull-out strength of the failed pedicle screw: biomechanical comparison of calcium sulfate vs polymethylmethacrylate augmentation
    Guler, Umit Ozgur
    Derincek, Alihan
    Hersekli, Murat Ali
    Ozalay, Metin
    Cinar, Bekir Murat
    Acaroglu, Emre
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 202 - 206
  • [23] Investigation of fixation screw pull-out strength on human spine
    Zhang, QH
    Tan, SH
    Chou, SM
    JOURNAL OF BIOMECHANICS, 2004, 37 (04) : 479 - 485
  • [24] Correlation of bone equivalent mineral density to pull-out resistance of triangulated pedicle screw construct
    Hadjipavlou, AG
    Nicodemus, CL
    AlHamdan, FA
    Simmons, JW
    Pope, MH
    JOURNAL OF SPINAL DISORDERS, 1997, 10 (01): : 12 - 19
  • [25] Monotonic and cyclic pull-out resistance of geogrids
    University College, University of New South Wales, Australia
    不详
    Geotechnique, 2 (331-337):
  • [26] Monotonic and cyclic pull-out resistance of geogrids
    Raju, DM
    Fannin, RJ
    GEOTECHNIQUE, 1997, 47 (02): : 331 - 337
  • [27] Biomechanical Evaluation of a Transtibial Pull-out Meniscal Root Repair Challenging the Bungee Effect
    Cerminara, Anthony J.
    LaPrade, Christopher M.
    Smith, Sean D.
    Ellman, Michael B.
    Wijdicks, Coen A.
    LaPrade, Robert F.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (12): : 2988 - 2995
  • [28] Effect of installation angle on pull-out resistance of nails in soil slopes
    Navid Najafi
    Rouzbeh Imani Kalehsar
    Meysam Khodaei
    Ali Naghi Dehghan
    Kasra Karroubi
    SN Applied Sciences, 2021, 3
  • [29] Effect of installation angle on pull-out resistance of nails in soil slopes
    Najafi, Navid
    Imani Kalehsar, Rouzbeh
    Khodaei, Meysam
    Dehghan, Ali Naghi
    Karroubi, Kasra
    SN APPLIED SCIENCES, 2021, 3 (08):
  • [30] Screw pull-out force is dependent on screw orientation in an anterior cervical plate construct
    DiPaola, Christian P.
    Jacobson, Justin A.
    Awad, Hani
    Conrad, Bryan P.
    Rechtine, Glenn R., II
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (05): : 369 - 373