Photon-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience

被引:17
|
作者
Dirrichs, Timm [1 ]
Tietz, Eric [1 ]
Rueffer, Andre [2 ]
Hanten, Jens [3 ]
Nguyen, Thai Duy [2 ]
Dethlefsen, Ebba [1 ]
Kuhl, Christiane K. [1 ]
机构
[1] RWTH Aachen Univ Hosp, Dept Diagnost & Intervent Radiol, Pauwelsstr 30, D-52074 Aachen, Germany
[2] RWTH Aachen Univ Hosp, Dept Pediat Heart Surg, Pauwelsstr 30, D-52074 Aachen, Germany
[3] RWTH Aachen Univ Hosp, Dept Pediat Cardiol, Pauwelsstr 30, D-52074 Aachen, Germany
关键词
D O I
10.1148/radiol.223088
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Photon-counting CT (PCCT) has been shown to improve cardiovascular CT imaging in adults. Data in neonates, infants, and young children under the age of 3 years are missing. Purpose: To compare image quality and radiation dose of ultrahigh-pitch PCCT with that of ultrahigh-pitch dual-source CT (DSCT) in children suspected of having congenital heart defects. Materials and Methods: This is a prospective analysis of existing clinical CT studies in children suspected of having congenital heart defects who underwent contrast-enhanced PCCT or DSCT in the heart and thoracic aorta between January 2019 and October 2022. CT dose index and dose-length product were used to calculate effective radiation dose. Signal-to-noise ratio (SNR) and contrast-tonoise ratio (CNR) were calculated by standardized region-of-interest analysis. SNR and CNR dose ratios were calculated. Visual image quality was assessed by four independent readers on a five-point scale: 5, excellent or absent; 4, good or minimal; 3, moderate; 2, limited or substantial; and 1, poor or massive. Results: Contrast-enhanced PCCT (n = 30) or DSCT (n = 84) was performed in 113 children (55 female and 58 male participants; median age, 66 days [IQR, 15-270]; median height, 56 cm [IQR, 52-67]; and median weight, 4.5 kg [IQR, 3.4-7.1]). A diagnostic image quality score of at least 3 was obtained in 29 of 30 (97%) with PCCT versus 65 of 84 (77%) with DSCT. Mean overall image quality ratings were higher for PCCT versus DSCT (4.17 vs 3.16, respectively; P <.001). SNR and CNR were higher for PCCT versus DSCT with SNR (46.3 +/- 16.3 vs 29.9 +/- 15.3, respectively; P =.007) and CNR (62.0 +/- 50.3 vs 37.2 +/- 20.8, respectively; P =.001). Mean effective radiation doses were similar for PCCT and DSCT (0.50 mSv vs 0.52 mSv; P =.47). Conclusion: At a similar radiation dose, PCCT offers a higher SNR and CNR and thus better cardiovascular imaging quality than DSCT in children suspected of having cardiac heart defects.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT
    Bette, Stefanie J.
    Braun, Franziska M.
    Haerting, Mark
    Decker, Josua A.
    Luitjens, Jan H.
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 2930 - 2936
  • [22] Dual-Source Photon-Counting Computed Tomography-Part I: Clinical Overview of Cardiac CT and Coronary CT Angiography Applications
    Cademartiri, Filippo
    Meloni, Antonella
    Pistoia, Laura
    Degiorgi, Giulia
    Clemente, Alberto
    Gori, Carmelo De
    Positano, Vincenzo
    Celi, Simona
    Berti, Sergio
    Emdin, Michele
    Panetta, Daniele
    Menichetti, Luca
    Punzo, Bruna
    Cavaliere, Carlo
    Bossone, Eduardo
    Saba, Luca
    Cau, Riccardo
    Grutta, Ludovico La
    Maffei, Erica
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (11)
  • [23] Photon-counting CT Material Decomposition: Initial Experience in Assessing Adrenal Adenoma
    Lennartz, Simon
    Schoenbeck, Denise
    Kroeger, Jan Robert
    Borggrefe, Jan
    Niehoff, Julius Henning
    RADIOLOGY, 2023, 306 (01) : 202 - 204
  • [24] Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography
    Muenzel, Daniela
    Bar-Ness, Daniel
    Roessl, Ewald
    Blevis, Ira
    Bartels, Matthias
    Fingerle, Alexander A.
    Ruschke, Stefan
    Coulon, Philippe
    Daerr, Heiner
    Kopp, Felix K.
    Brendel, Bernhard
    Thran, Axel
    Rokni, Michal
    Herzen, Julia
    Boussel, Loic
    Pfeiffer, Franz
    Proksa, Roland
    Rummeny, Ernst J.
    Douek, Philippe
    Noel, Peter B.
    RADIOLOGY, 2017, 283 (03) : 722 - 727
  • [25] First-generation clinical dual-source photon-counting CT: ultra-low-dose quantitative spectral imaging
    Liu, Leening P.
    Shapira, Nadav
    Chen, Andrew A.
    Shinohara, Russell T.
    Sahbaee, Pooyan
    Schnall, Mitchell
    Litt, Harold, I
    Noel, Peter B.
    EUROPEAN RADIOLOGY, 2022, 32 (12) : 8579 - 8587
  • [26] Abdominal image quality and dose reduction with energy-integrating or photon-counting detectors dual-source CT: A phantom study
    Greffiera, Joel
    Dabli, Djamel
    Faby, Sebastian
    Pastor, Maxime
    Croisille, Cedric
    de Oliveira, Fabien
    Erath, Julien
    Beregi, Jean Paul
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (10) : 379 - 385
  • [27] First-generation clinical dual-source photon-counting CT: ultra-low-dose quantitative spectral imaging
    Leening P. Liu
    Nadav Shapira
    Andrew A. Chen
    Russell T. Shinohara
    Pooyan Sahbaee
    Mitchell Schnall
    Harold I. Litt
    Peter B. Noël
    European Radiology, 2022, 32 : 8579 - 8587
  • [28] Low dose dual-source CT angiography in infants with complex congenital heart disease: a randomized study
    Gao, Yang
    Lu, Bin
    Hou, Zhihui
    Sun, Mingli
    Yu, Fangfang
    Cao, Huili
    Chen, Yang
    Han, Lei
    Jiang, Shiliang
    CARDIOLOGY, 2011, 120 : 68 - 68
  • [29] Low dose dual-source CT angiography in infants with complex congenital heart disease: A randomized study
    Gao, Yang
    Lu, Bin
    Hou, Zhihui
    Yu, Fangfang
    Cao, Huili
    Han, Lei
    Wu, Runze
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : E789 - E795
  • [30] Dual-source photon-counting computed tomography for coronary in-stent observation: influence of heart rate and virtual monoenergetic image
    Ogawa, Ryo
    Yanagawa, Masahiro
    Hata, Akinori
    Yamagata, Kazuki
    Ninomiya, Keisuke
    Doi, Shuhei
    Kikuchi, Noriko
    Tokuda, Yukiko
    Chimura, Misato
    Nakamura, Daisuke
    Itoh, Toshihide
    Kido, Teruhito
    Tomiyama, Noriyuki