Safety and effectiveness of magnetic ureteric stent removal under ultrasound control: a randomized single center trial

被引:3
|
作者
Li, Jingqiu [1 ]
Gauhar, Vineet [2 ]
Lim, Ee Jean [1 ]
Dmitriy, Shkarupa [3 ]
Vladimir, Obidnyak [4 ]
Dmitriy, Gorelov [4 ]
Igor, Semeniakin [5 ]
Gadzhiev, Nariman [3 ]
机构
[1] Singapore Gen Hosp, Dept Urol, Singapore, Singapore
[2] Ng Teng Feng Gen Hosp, Dept Urol, Singapore, Singapore
[3] St Petersburg State Univ Hosp, Dept Urol, Str Optikov 38, B1,App 35, St Petersburg 197342, Russia
[4] Pavlov First St Petersburg State Med Univ, St Petersburg State Univ Hosp, Dept Urol, St Petersburg, Russia
[5] Joint Stock Co Medsi Grp, Dept Urol, Moscow, Russia
关键词
Ureteral stent; Removal; Ultrasound; Retriever; QUALITY-OF-LIFE; SYMPTOMS;
D O I
10.1007/s00345-023-04437-5
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo assess the safety and effectiveness of magnetic ureteric stent removal with a special magnet retriever under ultrasound guidance.MethodsA total of 60 male patients, who underwent ureteroscopy from October 2020 to March 2022, were prospectively enrolled and randomized into two groups. Group A patients underwent conventional double-J (DJ) stent insertion and subsequent stent removal via flexible cystoscopy. Group B patients underwent stent insertion using magnetic ureteric stent [Blackstar, Urotech (Achenmuhle, Germany)] and stents were removed using a special magnet retriever under ultrasound guidance. Stents were left in situ for 30 days in both groups. All patients had follow-ups with a ureter stent symptoms questionnaire at 3- and 30-days post stent insertion. Visual analog scale (VAS) was assessed immediately after stent removal.ResultsStent removal time (142.5 s vs 142.5 s, group A vs group B, p < 0.0001) and VAS scores (4 vs 1, group A vs group B, p = 0.0008) were significantly lower in Group B. There were no statistically significant differences between both groups in the "urinary symptoms" (p = 0.3471) and "sexual matters" (p = 0.6126) in the USSQ domains. There was marginal statistical significance favoring Group A in the "body pain" (p = 0.0303), "general health score" (p = 0.0072), "additional problems" (p = 0.0142), and "work performance" (p < 0.0001) domains.ConclusionsMagnetic ureteric stent can be considered as a safe and efficient alternative to conventional DJ stent. This approach avoids the need for cystoscopy, saving resources while minimizing patient discomfort.
引用
收藏
页码:2889 / 2896
页数:8
相关论文
共 50 条
  • [41] Intravascular ultrasound-guided drug-eluting stent implantation for patients with unprotected left main coronary artery lesions: A single-center randomized trial
    Liu, Xiao-Ming
    Yang, Zuo-Ming
    Liu, Xiao-Kun
    Zhang, Qi
    Liu, Chang-Qing
    Han, Quan-Le
    Sun, Jian-Hua
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2019, 21 (02): : 83 - 90
  • [42] Effectiveness and safety of hominis placental pharmacopuncture for chronic temporomandibular disorder: A multi-center randomized controlled trial
    Park, Kyoung Sun
    Kim, Eun-San
    Kim, Koh-Woon
    Cho, Jae-Heung
    Lee, Yoon Jae
    Lee, Jinho
    Ha, In-Hyuk
    INTEGRATIVE MEDICINE RESEARCH, 2024, 13 (02)
  • [43] Effectiveness and safety of remimazolam combined with alfentanil in hysteroscopic examination: A prospective, randomized, single-blind trial
    Huang, Bei
    Li, Nan-Ping
    Tan, Gang-Kai
    Liang, Na
    MEDICINE, 2024, 103 (15) : E37627
  • [44] Comparison of Scoring Balloons Regarding the Effects on Post-Interventional Minimum Stent Area: A Single Center Randomized Trial
    Ishihara, Takayuki
    Iida, Osamu
    Fujita, Masashi
    Masuda, Masaharu
    Okamoto, Shin
    Nanto, Kiyonori
    Kanda, Takashi
    Okuno, Shota
    Matsuda, Yasuhiro
    Mano, Toshiaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B252 - B252
  • [45] Effect and Safety of Prophylactic Parecoxib for Pain Control of Transarterial Chemoembolization in Liver Cancer: A Single-Center, Parallel-Group, Randomized Trial
    Lyu, Ning
    Kong, Yanan
    Li, Xiaoxian
    Guo, Na
    Lai, Jinfa
    Li, Jibin
    Zhao, Ming
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2022, 19 (01) : 61 - 70
  • [46] Single-center study on the effectiveness and safety of stent and occluder in the treatment of patients with secondary malignant airway-digestive fistula
    Tang, Fei
    Lyu, Liping
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [47] The Effectiveness of Metacognitive Therapy Compared to Behavioral Activation for Severely Depressed Outpatients: A Single-Center Randomized Trial
    Schaich, Anja
    Outzen, Janne
    Assmann, Nele
    Gebauer, Carlotta
    Jauch-Chara, Kamila
    Alvarez-Fischer, Daniel
    Huppe, Michael
    Wells, Adrian
    Schweiger, Ulrich
    Klein, Jan Philipp
    Fassbinder, Eva
    PSYCHOTHERAPY AND PSYCHOSOMATICS, 2023, 92 (01) : 38 - 48
  • [48] Feasibility, Safety and Effectiveness of fluoroscopic electrophysiological Studies - a Single Center Case-control Pilot Study
    Blessberger, H.
    Nahler, A.
    Hrncic, D.
    Lambert, T.
    Spitzer, S.
    Kiblboeck, D.
    Saleh, K.
    Schwarz, S.
    Reiter, C.
    Fellner, A.
    Kellermair, J.
    Kammler, J.
    Steinwender, C.
    WIENER KLINISCHE WOCHENSCHRIFT, 2022, 134 (SUPPL 2) : 168 - 169
  • [49] A prospective randomized trial comparing time different analgesic techniques for pain control during transrectal ultrasound guided prostate biopsy: a single center experience
    Anup, K.
    Pawan, V.
    Niraj, K.
    Biswajit, N.
    Nayan, M. K.
    MINERVA UROLOGICA E NEFROLOGICA, 2013, 65 (01) : 77 - 82
  • [50] Effectiveness and Safety of Laser-Assisted Removal of Inferior Vena Cava (IVC) Filters in a Single Tertiary Care Center
    Alhussaini, Abdulmohsen
    Alahmad, Mohammed A.
    Alomaim, Mohammad M.
    Alzahrani, Mohammed Y.
    Alghamdi, Abdullah S.
    Arabi, Mohammad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)