Study of using the loss rate of bolt pretension as a damage predictor for steel connections

被引:1
|
作者
Chen, Chui - Hsin [1 ]
Lai, Chi - Ming [2 ]
Lin, Ker - Chun [3 ]
Jhuang, Sheng - Jhih [3 ]
Chang, Heui - Yung [4 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Dept Civil Engn, 1001,Univ Rd, Hsinchu 300, Taiwan
[2] Natl Cheng Kung Univ, Dept Civil Engn, 1,Univ Rd, Tainan 701, Taiwan
[3] Natl Ctr Res Earthquake Engn, Natl Appl Res Labs, 200 Sec 3,HsinHai Rd, Taipei 106, Taiwan
[4] Natl Chung Hsing Univ, Dept Civil Engn, 145 Xingda Rd, Taichung 402, Taiwan
关键词
damage predictor; loading protocol; loss rate of bolt pretension; moment connections; steel buildings; SEISMIC PERFORMANCE ASSESSMENT; BEAM-COLUMN CONNECTIONS; HIGH-STRENGTH BOLTS; FRAMES; BUILDINGS; DESIGN; EARTHQUAKES; LESSONS;
D O I
10.12989/eas.2023.24.2.081
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The maximum drifts are important to the seismic evaluation of steel buildings and connections, but the information can hardly be obtained from the post-earthquake field investigation. This research studies the feasibility of using the loss rate of bolt pretension as an earthquake damage predictor. Full-scale tests were made on four steel connections using bolted-webwelded-flange details. One connection was unreinforced (UN), another was reinforced with double shear plates (DS), and the other two used reduced beam sections (RBS). The preinstalled strain gauges were used to control the pretensions and monitor the losses of the high-strength bolts. The results showed that the loss rate of bolt pretension was highly related to the damage of the connections. The pretensions lost up to 10% in all the connections at the yield drifts of 0.5% to 1%. After yielding of the connections, the pretensions lost significantly until fracture occurred. The UN and DS connections failed with a maximum drift of 4 %, and the two RBS connections showed better ductility and failed with a maximum drift of 6%. Under the far-field-type loading protocol, the loss rate grew to 60%. On the contrary, the rate for the specimen under near-fault-type loading protocol was about 40%. The loss rate of bolt pretension is therefore recommended to use as an earthquake damage predictor. Additionally, the 10% and 40% loss rates are recommended to predict the limit states of connection yielding and maximum strength, respectively, and to define the performance levels of serviceability and life-safety for the buildings.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 50 条
  • [41] FUNDAMENTAL STUDY ON SEISMIC RETROFIT FOR ANGLE BRACE CONNECTIONS OF TRANSMISSION TOWER USING STEEL PLATE ADHESIVE BONDING
    Nakamura T.
    Terazawa Y.
    Takeuchi T.
    Journal of Structural and Construction Engineering, 2024, 89 (818): : 462 - 472
  • [42] Numerical study of damage in particulate composites during high-strain rate loading using novel damage model
    Lee, Sangmin
    Ramos, Katherine
    Matous, Karel
    MECHANICS OF MATERIALS, 2021, 160 (160)
  • [43] Direct Formed High-Strength Bolt with Hot-Rolled Twinning-Induced Plasticity Steel Using Its High Strain Hardening Rate
    Joong-Ki Hwang
    Journal of Materials Engineering and Performance, 2022, 31 : 272 - 285
  • [44] Study of the Hydrogen Delayed Fracture of Mooring Chain Steel using Strain Rate Testing
    Li, Songjie
    Sun, Panfei
    Yin, Jiang
    Wang, Maoqiu
    Wang, Chengduo
    Shao, Lixiang
    Li, Fan
    Li, Yuanyuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09): : 9221 - 9230
  • [45] Direct Formed High-Strength Bolt with Hot-Rolled Twinning-Induced Plasticity Steel Using Its High Strain Hardening Rate
    Hwang, Joong-Ki
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2022, 31 (01) : 272 - 285
  • [46] A case study of damage detection in four-bays steel structures using the HHT approach
    Hsu, Wen-Ko
    Chiou, Dung-Jiang
    Chen, Cheng-Wu
    Liu, Ming-Yi
    Chiang, Wei-Ling
    Huang, Pei-Chiung
    SMART STRUCTURES AND SYSTEMS, 2014, 14 (04) : 595 - 615
  • [47] Internal longitudinal damage detection in a steel beam using Lamb waves: Simulation and test study
    Park, Chan Yik
    Palazotto, Anthony N.
    Hale, Chad S.
    Jung, Hwee Kwon
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2018, 29 (03) : 411 - 422
  • [48] Study on the radiation damage and recovery of neutron irradiated vessel steel using magnetic Barkhausen noise
    Park, Duck-Gun
    Jeong, Hee-Tae
    Hong, Jun-Hwa
    Journal of Applied Physics, 1999, 85 (8 II B) : 5726 - 5728
  • [49] A study on the radiation damage and recovery of neutron irradiated vessel steel using magnetic Barkhausen noise
    Park, DG
    Jeong, HT
    Hong, JH
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (08) : 5726 - 5728
  • [50] Noninvasive fluid dynamic power loss assessments for total cavopulmonary connections using the viscous dissipation function: A feasibility study
    Healy, TM
    Lucas, C
    Yoganathan, AP
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (04): : 317 - 324