Saliva with different concentrations of enzyme with esterolytic activity, and its effect on the immediate and long-term bond strength of adhesive systems to dentin

被引:1
|
作者
Barros, Leonardo Santos [1 ]
Basting, Roberta Tarkany [1 ]
Vieira-Junior, Waldemir Francisco [1 ]
Franca, Fabiana Mantovani Gomes [1 ]
do Amaral, Flavia Lucisano Botelho [1 ]
Turssi, Cecilia Pedroso [1 ,2 ]
机构
[1] Sao Leopoldo Mandic Dent Inst, Div Cariol & Restorat Dent, Dept Orthodont, Campinas, SP, Brazil
[2] Inst & Ctr Pesquisas Odontol Sao Leopoldo Mandic, Rua Jose Rocha Junqueira 13, BR-13045755 Campinas, SP, Brazil
关键词
Aging; Albumin; Enzymatic degradation; Hybrid layer; Micro; -tensile; ETCH ADHESIVE; RESIN; BIODEGRADATION; LEACHABILITY; DEGRADATION; COMPOSITES; STRATEGIES; ESTERASE; WATER; MMPS;
D O I
10.1016/j.ijadhadh.2024.103657
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The present study evaluated whether different concentrations of albumin would influence the immediate or longterm bond strength of adhesive systems to dentin. Human third molars (N = 90) were sectioned at the dentinenamel junction to obtain middle dentin occlusal surfaces. After sectioning into discs, the molars were restored with resin composite (Filtek Z250, 3 M/ESPE) by using an etch-and-rinse (Adper Scotchbond MultiPurpose, 3 M/ESPE) or a self-etch (Clearfil SE Bond, Kuraray) adhesive system. The specimens were then sectioned into beams and stored in artificial saliva containing albumin in regular (100 mu g/mL; SA100) or elevated (700 mu g/mL; SA700) concentration-both concentrations simulated the range in which this enzyme may be present clinically, depending on the patient's periodontal condition. Beams from the control group (CO) were kept in artificial saliva with no addition of albumin. Half of the beams from each group were stored for 24 h, and the remainder, for 12 months. Then, the microtensile bond strength test was performed, and the failure mode was analyzed (adhesive, cohesive, or mixed). Bond strength data were submitted to the generalized linear model, followed by the Tukey tests, and failure modes were compared using chi-square tests (alpha = 5%). There were no significant interactions, but there was a significant effect between the albumin concentration (p = 0.015) and the time factor (p = 0.016). The beams stored in SA700 had significantly lower bond strength in comparison with the CO beams, regardless of the adhesive system. At 12 months, the bond strength decreased significantly for all groups. SA700 caused a significant increase in the adhesive failures after 12 months (p = 0.005). It was concluded that the bond strength of both adhesive systems was impaired by the albumin concentration aging.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] LONG-TERM BOND STRENGTH OF A MULTIMODE ADHESIVE TO DENTIN
    Eger, M.
    Segal, P.
    Brosh, T.
    Pilo, R.
    Levartovsky, S.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (04): : 1209 - 1214
  • [2] Long-term bond strength of adhesive systems applied to etched and deproteinized dentin
    Uceda-Gomez, Ninoshka
    Loguercio, Alessandro Dourado
    Moura, Sandra Kiss
    Miranda Grande, Rosa Helena
    Oda, Margareth
    Reis, Alessandra
    JOURNAL OF APPLIED ORAL SCIENCE, 2007, 15 (06) : 475 - 479
  • [3] Effect of Different Adhesive Systems Used for Immediate Dentin Sealing on Bond Strength of a Self-Adhesive Resin Cement to Dentin
    Ferreira-Filho, R. C.
    Ely, C.
    Amaral, R. C.
    Rodrigues, J. A.
    Roulet, J-F
    Cassoni, A.
    Reis, A. F.
    OPERATIVE DENTISTRY, 2018, 43 (04) : 391 - 397
  • [4] Effect of Galardin and its Solvents on the Microtensile Bond Strength of Different Adhesive Systems to Dentin
    Chaharom, Mohammad Esmaeel Ebrahimi
    Bahari, Mahmoud
    Rahbar, Mahdi
    Golbaz, Sepideh
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2019, 19 (01):
  • [5] Dentin bond strength of different adhesive systems.
    Prado, C
    Triana, R
    Soler, L
    Forner, L
    Guinea, E
    Llena, C
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1228 - 1228
  • [6] Long-Term Bond Strength of Two Benzalkonium Chloride-Modified Adhesive Systems to Eroded Dentin
    Flury, Simon
    Lussi, Adrian
    Peutzfeldt, Anne
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [7] Shear bond strength of adhesive systems to saliva contaminated dentin surfaces.
    Salvio, LA
    Sinhoreti, MAC
    Sobrinho, LC
    Consani, S
    Konno, ANK
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B167 - B167
  • [8] Bond strength in enamel and dentin of different adhesive systems.
    Souza, WCS
    Seixas, LC
    Ciccone, JC
    Ramos, RP
    Chimello, DT
    Dibb, RGP
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 184 - 184
  • [9] Influence of disinfectants on dentin bond strength of different adhesive systems
    Betke, H
    Ziebolz, D
    Rien, C
    Blunck, U
    Attin, T
    OPERATIVE DENTISTRY, 2005, 30 (02) : 250 - 256
  • [10] Comparison of Different Universal Adhesive Systems on Dentin Bond Strength
    Brkanovic, Sandra
    Sever, Eva Klaric
    Vukelja, Josipa
    Ivica, Anja
    Miletic, Ivana
    Krmek, Silvana Jukic
    MATERIALS, 2023, 16 (04)