Chance constrained robust hydrogen storage management to service restoration in microgrids considering the methanation process model

被引:2
|
作者
Afsari, Navid [1 ]
Seyedshenava, Seyedjalal [1 ]
Shayeghi, Hossein [1 ]
机构
[1] Univ Mohaghegh Ardabili, Dept Elect & Comp Engn, Ardebil, Iran
关键词
Service restoration; Reconfiguration; Hydrogen storage system; Electric vehicles; Adaptive distributionally robust optimization; Tri-level robust model; ENERGY SYSTEM; NATURAL-GAS; WIND POWER; OPTIMIZATION; ELECTRICITY;
D O I
10.1016/j.ijhydene.2023.10.011
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
After a natural disaster, electrical grids might go into a self-healing mode to restore service and reconnect any customers that lost power. In the self-heal system, the fast operation and restoring the critical loads (CLs) during a fault by available resources can increase the flexibility and resilience of the network. In addition to renewable energy sources and electric vehicles (EVs) storage devices, the hydrogen storage system and the process of converting hydrogen into electric energy by micro-gas turbine (MGT) have been modeled in order to assess the impact of this storage system in electrical loads restoration in critical conditions. Self-healing functionality is enhanced by using alternative and novel energy sources. In such a situation, how to interact with the stochastic nature of network components will be challenging. This paper formulates the optimal service restoration (SR) problem using chance-constrained Adaptive Distributionally Robust Optimization (ADRO) to address the am-biguities introduced by the uncertain parameters. A tri-level robust optimization model is developed such that the optimal switching in the network until clearing the fault is determined at the upper level, and the maxi-mization of the SR based on the load demand values is determined at the lower level. The proposed method is demonstrated by simulation results on the modified Civanlar test system. In an equal operating condition and considering beta = 3, it can be seen that the initial hydrogen State of the Tank (SoT) by 50 % can improve the load restoration by 7.5 % compared to the uncharged hydrogen tank. By increasing the initial SoT to the nominal value (10 Kg), the load restoration can increase to 13.2 %.
引用
收藏
页码:1463 / 1476
页数:14
相关论文
共 39 条
  • [31] Research on the Collaborative Operation of Diversified Energy Storage and Park Clusters: A Method Combining Data Generation and a Distributionally Robust Chance-Constrained Operational Model
    Siqin, Zhuoya
    Qiao, Tiantong
    Diao, Ruisheng
    Wang, Xuejie
    Xu, Guangjun
    ELECTRONICS, 2024, 13 (24):
  • [32] A multi-objective robust optimal dispatch and cost allocation model for microgrids-shared hybrid energy storage system considering flexible ramping capacity
    Pan, Yushu
    Ju, Liwei
    Yang, Shenbo
    Guo, Xinyu
    Tan, Zhongfu
    APPLIED ENERGY, 2024, 369
  • [33] Designing an integrated municipal solid waste management system using a fuzzy chance-constrained programming model considering economic and environmental aspects under uncertainty
    Zaeimi, Mehdi Bavaghar
    Rassafi, Amir Abbas
    WASTE MANAGEMENT, 2021, 125 : 268 - 279
  • [34] Bilevel model for security-constrained and reliability transmission and distribution substation energy management considering large-scale energy storage and demand side management
    Jokar, Hossein
    Bahmani-Firouzi, Bahman
    Simab, Mohsen
    ENERGY REPORTS, 2022, 8 : 2617 - 2629
  • [35] Bilevel model for security-constrained and reliability transmission and distribution substation energy management considering large-scale energy storage and demand side management
    Jokar, Hossein
    Bahmani-Firouzi, Bahman
    Simab, Mohsen
    ENERGY REPORTS, 2022, 8 : 2617 - 2629
  • [36] Bilevel model for security-constrained and reliability transmission and distribution substation energy management considering large-scale energy storage and demand side management
    Jokar, Hossein
    Bahmani-Firouzi, Bahman
    Simab, Mohsen
    Energy Reports, 2022, 8 : 2617 - 2629
  • [37] A tri-objectives scheduling model for renewable-hydrogen-based microgrid system considering hydrogen storage system and demand-side management
    Karimi, Hamid
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 68 : 1412 - 1422
  • [38] Chance-constrained model predictive control-based operation management of more-electric aircraft using energy storage systems under uncertainty
    Wang, Xin
    Bazmohammadi, Najmeh
    Atkin, Jason
    Bozhko, Serhiy
    Guerrero, Josep M.
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [39] A mixed-integer-linear-logical programming interval-based model for optimal scheduling of isolated microgrids with green hydrogen-based storage considering demand response
    Tostado-Veliz, Marcos
    Kamel, Salah
    Hasanien, Hany M.
    Turky, Rania A.
    Jurado, Francisco
    JOURNAL OF ENERGY STORAGE, 2022, 48