Patient-Specific Computer Modeling to Guide Redo Transcatheter Aortic Valve Replacement

被引:2
|
作者
Dargan, James [1 ]
Kenawi, Abdelrahman
Khan, Faisal
Firoozi, Sami
Brecker, Stephen
机构
[1] St George Hosp, Dept Cardiol, Blackshaw Rd, London SW17 0QT, England
关键词
computer modeling; TAVR; re-do; simulation;
D O I
10.1016/j.jcin.2023.07.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:2332 / 2334
页数:3
相关论文
共 50 条
  • [41] Patient-specific simulations of transcatheter aortic valve stent implantation
    C. Capelli
    G. M. Bosi
    E. Cerri
    J. Nordmeyer
    T. Odenwald
    P. Bonhoeffer
    F. Migliavacca
    A. M. Taylor
    S. Schievano
    Medical & Biological Engineering & Computing, 2012, 50 : 183 - 192
  • [42] Review of patient-specific simulations of transcatheter aortic valve implantation
    Vy, P.
    Auffret, V.
    Badel, P.
    Rochette, M.
    Le Breton, H.
    Haigron, P.
    Avril, S.
    INTERNATIONAL JOURNAL OF ADVANCES IN ENGINEERING SCIENCES AND APPLIED MATHEMATICS, 2016, 8 (01) : 2 - 24
  • [43] Transcatheter aortic valve replacement aortic root orientation: implications for future coronary access and redo transcatheter aortic valve replacement
    Alexis, Sophia L.
    Zaid, Syed
    Sengupta, Aditya
    Lerakis, Stamatios
    Khera, Sahil
    Sharma, Samin K.
    Kini, Annapoorna
    Tang, Gilbert H. L.
    ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (06) : 502 - 504
  • [44] Simulation of Transcatheter Aortic Valve Replacement in patient-specific aortic roots: effect of crimping and positioning on device performance
    Bianchi, Matteo
    Ghosh, Ram P.
    Marom, Gil
    Slepian, Marvin J.
    Bluestein, Danny
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 282 - 285
  • [45] Insight on patient specific computer modeling of transcatheter aortic valve implantation in patients with bicuspid aortic valve disease
    Brouwer, Jorn
    Gheorghe, Livia
    Nijenhuis, Vincent J.
    ten Berg, Jurrien M.
    Rensing, Benno J. W. M.
    van der Heyden, Jan A. S.
    Swaans, Martin J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (06) : 1097 - 1105
  • [46] Patient-specific computer simulation to optimise transcatheter heart valve sizing and positioning in bicuspid aortic valve morphology
    Dowling, Cameron
    Bavo, Alessandra
    Mortier, Peter
    El Faquir, Nahid
    de Jaegere, Peter
    De Backer, Ole
    Sondergaard, Lars
    Ruile, Philipp
    Mylotte, Darren
    McConkey, Hannah
    Rajani, Ronak
    Laborde, Jean-ClauDe
    Brecker, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B167 - B167
  • [47] Fluid Simulation of a Transcatheter Aortic Valve Deployment into a Patient-Specific Aortic Root
    Sirois E.
    Wang Q.
    Sun W.
    Cardiovascular Engineering and Technology, 2011, 2 (3) : 186 - 195
  • [48] Redo in aortic homograft replacement: Transcatheter aortic valve as a valid alternative to surgical replacement
    Dainese, Luca
    Fusari, Melissa
    Trabattoni, Piero
    Biglioli, Paolo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (06): : 1656 - 1657
  • [49] Differences in clinical valve size selection and valve size selection for patient-specific computer simulation in transcatheter aortic valve replacement (TAVR): a retrospective multicenter analysis
    Nahid El Faquir
    Giorgia Rocatello
    Zouhair Rahhab
    Johan Bosmans
    Ole De Backer
    Nicolas M. Van Mieghem
    Peter Mortier
    Peter P. T. de Jaegere
    The International Journal of Cardiovascular Imaging, 2020, 36 : 123 - 129
  • [50] Differences in clinical valve size selection and valve size selection for patient-specific computer simulation in transcatheter aortic valve replacement (TAVR): a retrospective multicenter analysis
    El Faquir, Nahid
    Rocatello, Giorgia
    Rahhab, Zouhair
    Bosmans, Johan
    De Backer, Ole
    Van Mieghem, Nicolas M.
    Mortier, Peter
    de Jaegere, Peter P. T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (01): : 123 - 129