The NCS code of practice for the quality assurance of treatment planning systems (NCS-35)

被引:2
|
作者
Schuring, D. [1 ]
Westendorp, H. [2 ]
van der Bijl, E. [3 ]
Bol, G. H. [4 ]
Crijns, W. [5 ]
Delor, A. [6 ]
Jourani, Y. [7 ]
Ong, C. Loon [8 ]
Penninkhof, J. [9 ]
Kierkels, R. [1 ]
Verbakel, W. [10 ]
van de Water, T. [11 ]
van de Kamer, J. B. [12 ]
机构
[1] Radiat Oncol Dept, Radiotherapiegroep, Deventer, Netherlands
[2] Isala Hosp, Oncol Dept, Zwolle, Netherlands
[3] Radboud Univ Nijmegen, Radiat Oncol Dept, Med Ctr, Nijmegen, Netherlands
[4] Univ Med Ctr Utrecht, Radiotherapy Dept, Utrecht, Netherlands
[5] Katholieke Univ Leuven, UZ Leuven, Oncol Dept, Radiat Oncol, Leuven, Belgium
[6] Clin Univ St Luc, Inst Roi Albert II, Radiat Oncol Dept, Brussels, Belgium
[7] Univ Libre Bruxelles, Inst Jules Bordet, Med Phys Dept, Brussels, Belgium
[8] Haga Hosp, Radiat Oncol Dept, The Hague, Netherlands
[9] Erasmus MC, Univ Med Ctr Rotterdam, Radiat Oncol Dept, Canc Inst, Rotterdam, Netherlands
[10] Amsterdam Univ Med Ctr locat VUmc, Radiat Oncol Dept, Amsterdam, Netherlands
[11] Radiotherapeut Inst Friesland, Leeuwarden, Netherlands
[12] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 20期
关键词
treatment planning; quality assurance; commissioning; code of practice; RADIATION-THERAPY; DOSE CALCULATIONS; COMPLEXITY; PHOTON; FIELDS; QA;
D O I
10.1088/1361-6560/acfd06
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A subcommittee of the Netherlands Commission on Radiation Dosimetry (NCS) was initiated in 2018 with the task to update and extend a previous publication (NCS-15) on the quality assurance of treatment planning systems (TPS) (Bruinvis et al 2005). The field of treatment planning has changed considerably since 2005. Whereas the focus of the previous report was more on the technical aspects of the TPS, the scope of this report is broader with a focus on a department wide implementation of the TPS. New sections about education, automated planning, information technology (IT) and updates are therefore added. Although the scope is photon therapy, large parts of this report will also apply to all other treatment modalities. This paper is a condensed version of these guidelines; the full version of the report in English is freely available from the NCS website (http://radiationdosimetry.org/ncs/publications). The paper starts with the scope of this report in relation to earlier reports on this subject. Next, general aspects of the commissioning process are addressed, like e.g. project management, education, and safety. It then focusses more on technical aspects such as beam commissioning and patient modeling, dose representation, dose calculation and (automated) plan optimisation. The final chapters deal with IT-related subjects and scripting, and the process of updating or upgrading the TPS.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Quality assurance of Treatment Planning Systems: upgrading the NCS report 15
    Jourani, Y.
    Delor, A.
    Crijns, W.
    Bol, G.
    Kierkels, R. G. J.
    Ong, C. L.
    Penninkhof, J.
    van der Bijl, E.
    van de Water, T. A.
    Verbakel, W.
    Schuring, D.
    Westendorp, R.
    van de Kamer, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S431 - S432
  • [2] The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy
    Mans, Anton
    Schuring, Danny
    Arends, Mark P.
    Vugts, Cornelia A. J. M.
    Wolthaus, Jochem W. H.
    Lotz, Heidi T.
    Admiraal, Marjan
    Louwe, Rob J. W.
    Ollers, Michel C.
    van de Kamer, Jeroen B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (19): : 7221 - 7235
  • [3] Quality Assurance of TPS, Based On 'Code of Practice for Quality Control of Treatment Planning Systems in Radiation Therapy' by SEFM (Spanish Medical Physics Association)
    Lozares, S.
    Pellejero, S.
    Miquelez, S.
    Maneru, F.
    Martin, M.
    Bragado, L.
    Soto, P.
    Rubio, A.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Quality assurance of treatment planning systems:: The QUASIMODO project
    Olszewska, A
    Fiorino, C
    Knöös, T
    Mijnheer, B
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S73 - S73
  • [5] Quality assurance of PCR TTPS, based on "code of practice for quality control of treatment planning systems in radiation therapy" by SEFM (Sociedad Espanola de Fisica Medica)
    Pellejero, S.
    Lozares, S.
    Quintana, C.
    Maneru, F.
    Miquelez, S.
    Soto, P.
    Martin, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S250 - S250
  • [6] Implementation of a quality assurance program for computerized treatment planning systems
    Camargo, Priscilla R. T. L.
    Rodrigues, Laura N.
    Furnari, Laura
    Rubo, Rodrigo A.
    MEDICAL PHYSICS, 2007, 34 (07) : 2827 - 2836
  • [7] THE DEVELOPMENT OF QUALITY ASSURANCE FOR SHEFFIELDS RADIOTHERAPY TREATMENT PLANNING SYSTEMS
    WHILDE, NJ
    CONWAY, J
    BOMFORD, CK
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (792): : 1182 - 1185
  • [8] An Automated Method for the Verification and Quality Assurance of Treatment Planning Systems
    Oh, S.
    Lee, D.
    Leong, B.
    Wu, Y.
    Kim, S.
    Kim, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 2939 - 2940
  • [9] Quality assurance of radiation treatment planning systems: A significant challenge?
    Van Dyk, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2051 - 2051
  • [10] IMPLEMENTATION OF A QUALITY ASSURANCE PROGRAM FOR COMPUTERIZED TREATMENT PLANNING SYSTEMS
    Ribeiro, F.
    Macedo, S.
    Oliveira, M.
    Oliveira, A.
    Santos, O.
    Simao, C.
    Roldao, M.
    Faria, J.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S493 - S493