Implementation of a quality assurance program for computerized treatment planning systems

被引:3
|
作者
Camargo, Priscilla R. T. L.
Rodrigues, Laura N.
Furnari, Laura
Rubo, Rodrigo A.
机构
[1] IPEN, CNEN, Ctr Metrol Radiacoes, BR-05508900 Sao Paulo, Brazil
[2] Univ Sao Paulo, Fac Med, INRAD, Hosp Clin, BR-05403001 Sao Paulo, Brazil
关键词
D O I
10.1118/1.2742779
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the present investigation, the necessary tests for implementing a quality assurance program for a commercial treatment planning system (TPS), recently installed at Sao Paulo University School of Medicine Clinicas Hospital-Brazil, was established and performed in accordance with the new IAEA publication TRS 430, and with AAPM Task Group 53. The tests recommended by those documents are classified mainly into acceptance, commissioning (dosimetric and nondosimetric), periodic quality assurance, and patient specific quality assurance tests. The recommendations of both IAEA and AAPM documents are being implemented at the hospital for photon beams produced by two linear accelerators. A Farmer ionization chamber was used in a 30 x 30 x 30 cm(3) phantom with a dose rate of 320 monitor unit (MU)/min and 50 MU in the case of the dosimetric tests. The acceptance tests verified hardware, network systems integration, data transfer, and software parameters. The results obtained are in good agreement with the specifications of the manufacturer. For the commissioning dosimetric tests, the absolute dose was measured for simple geometries, such as square and rectangular fields, up to more complex geometries such as off-axis hard wedges and for behavior in the build up region. Results were analysed by the use of confidence limit as proposed by Venselaar et al. [Radio Ther. Oncol. 60, 191-201 (2001)]. Criteria of acceptability had been applied also for the comparison between the values of MU calculated manually and MU generated by TPS. The results of the dosimetric tests show that work can be reduced by choosing to perform only those that are more crucial, such as oblique incidence, shaped fields, hard wedges, and buildup region behavior. Staff experience with the implementation of the quality assurance program for a commercial TPS is extremely useful as part of a training program. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:2827 / 2836
页数:10
相关论文
共 50 条
  • [1] IMPLEMENTATION OF A QUALITY ASSURANCE PROGRAM FOR COMPUTERIZED TREATMENT PLANNING SYSTEMS
    Ribeiro, F.
    Macedo, S.
    Oliveira, M.
    Oliveira, A.
    Santos, O.
    Simao, C.
    Roldao, M.
    Faria, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S493 - S493
  • [2] QUALITY ASSURANCE OF COMPUTERIZED THERAPY PLANNING SYSTEMS
    BRAHMAVAR, SM
    LAFRANCE, M
    PARK, WC
    [J]. MEDICAL PHYSICS, 1982, 9 (04) : 638 - 639
  • [3] Implementation of a quality assurance program to reduce treatment delivery overrides
    Klash, S
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1201 - 1201
  • [4] Quality assurance of treatment planning systems:: The QUASIMODO project
    Olszewska, A
    Fiorino, C
    Knöös, T
    Mijnheer, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S73 - S73
  • [5] IMPLEMENTATION OF OPERATIONAL QUALITY ASSURANCE PROGRAM
    VIERZBA, EA
    PHILIPS, MH
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 21 : 2 - 3
  • [6] DEVELOPMENT AND IMPLEMENTATION OF A QUALITY ASSURANCE PROGRAM
    LANG, P
    [J]. TRANSFUSION, 1992, 32 (08) : S88 - S88
  • [7] QUALITY ASSURANCE BY COMPUTERIZED ENDOSCOPY RECORD SYSTEMS
    ZWIEBEL, FM
    SAUERBRUCH, T
    [J]. ENDOSCOPY, 1992, 24 : 527 - 531
  • [8] THE DEVELOPMENT OF QUALITY ASSURANCE FOR SHEFFIELDS RADIOTHERAPY TREATMENT PLANNING SYSTEMS
    WHILDE, NJ
    CONWAY, J
    BOMFORD, CK
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (792): : 1182 - 1185
  • [9] Quality assurance of radiation treatment planning systems: A significant challenge?
    Van Dyk, J
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2051 - 2051
  • [10] An Automated Method for the Verification and Quality Assurance of Treatment Planning Systems
    Oh, S.
    Lee, D.
    Leong, B.
    Wu, Y.
    Kim, S.
    Kim, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2939 - 2940