Research on individualized distribution approach of coronary resting blood flow for noninvasive calculation of fractional flow reserve

被引:2
|
作者
Zhang, Honghui [1 ]
Wu, Rile [2 ]
Yang, Ning [3 ]
Xie, Jinjie [4 ]
Hou, Yang [5 ]
机构
[1] Inner Mongolia Minzu Univ, Coll Engn, Tongliao 028000, Peoples R China
[2] Tong Liao City Hosp, Dept Neurol, Tongliao 028007, Peoples R China
[3] Harbin Med Univ, Affiliated Hosp 1, Dept Cardiol, Harbin 150001, Peoples R China
[4] Jiahui Int Hosp, Dept Echocardiog, Shanghai 200233, Peoples R China
[5] China Med Univ, Shengjing Hosp, Shenyang 110001, Peoples R China
基金
中国国家自然科学基金;
关键词
Fractional flow reserve; Coronary ultrasound; Individualized; Coronary resting blood flow; Coronary stenosis; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; SCALING LAWS; ANGIOGRAPHY; DESIGN; QUANTIFICATION; IMPACT; ARTERY; MODEL; TREE;
D O I
10.1016/j.cmpb.2023.107704
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objectives: The distribution of coronary resting blood flow is critical for accurately calculating the computed tomography (CT) angiography-derived fractional flow reserve (FFR CT ). However, the diagnostic accuracy of FFR CT calculated by the fixed exponents between two risk factors and coronary resting blood flow, including myocardial mass and diameter of the coronary artery branch, was insufficient compared with invasive fractional flow reserve (FFR). In this study, we proposed the individualized distribution of coronary resting blood flow based on coronary ultrasound blood flow measurement, to improve the diagnostic accuracy of FFR CT calculation. Methods: Five risk factors and an unknown coefficient K were integrated to calculate the individualized distribution of coronary resting blood flow. The K value was fit using the least square method based on coronary ultrasound blood flow measurement results of 30 volunteers. We developed a novel approach for calculating the individualized distribution of coronary resting blood flow and applied it to calculate FFR CT (FFR CTI ). Then, we tested the performance of the individualized distribution approach by comparing it with the approach proposed by Taylor based on coronary ultrasound blood flow measurement results of 13 volunteers. Finally, we tested the diagnostic accuracy of FFR CT calculated by two approaches in invasive FFR of 121 vessels with coronary stenosis. Results: We identified five risk factors and 6.83 x10 -5 for K value, including cardiac output, mean arterial pressure, myocardial mass, coronary artery volume, and diameter of the coronary artery branch, to calculate the individualized distribution of coronary resting blood flow. The mean square error of the individualized distribution approach (0.0088) was significantly less than that of the approach proposed by Taylor (0.0799). The diagnostic accuracy of FFR CTI calculated by the individualized distribution approach (91.74%) was higher than that of the approach proposed by Taylor (FFR CTT ) (82.64%). Conclusions: The individualized distribution approach of coronary resting blood flow can significantly improve the diagnostic accuracy of FFR CT calculation compared with invasive FFR, and support its wide clinical application for diagnosing myocardial ischemia caused by coronary stenosis. & COPY; 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Noninvasive Derivation of Fractional Flow Reserve From Coronary Computed Tomographic Angiography A Review
    Benton, Stewart M., Jr.
    Tesche, Christian
    De Cecco, Carlo N.
    Duguay, Taylor M.
    Schoepf, U. Joseph
    Bayer, Richard R., II
    JOURNAL OF THORACIC IMAGING, 2018, 33 (02) : 88 - 96
  • [32] Deep learning for prediction of fractional flow reserve from resting coronary pressure curves
    Zimmermann, Frederik M.
    Mast, Thomas P.
    Johnson, Nils P.
    Everts, Ivo
    Hennigan, Barry
    Berry, Colin
    Johnson, Daniel T.
    De Bruyne, Bernard
    Fearon, William F.
    Oldroyd, Keith G.
    Pijls, Nico H. J.
    Tonino, Pim A. L.
    van 't Veer, Marcel
    EUROINTERVENTION, 2021, 17 (01) : 51 - +
  • [33] Fractional Flow Reserve Modeled From Resting Coronary CT Angiography: State of the Science
    Precious, Bruce
    Blanke, Philipp
    Norgaard, Bjarne L.
    Min, James K.
    Leipsic, Jonathon
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : W243 - W248
  • [34] Qualitative resting coronary pressure wave form analysis to predict fractional flow reserve
    Matsumura, Mitsuaki
    Maehara, Akiko
    Johnson, Nils P.
    Fearon, William F.
    De Bruyne, Bernard
    Oldroyd, Keith G.
    Pijls, Nico H. J.
    Jenkins, Paul
    Ali, Ziad A.
    Mintz, Gary S.
    Stone, Gregg W.
    Jeremias, Allen
    EUROINTERVENTION, 2019, 14 (15) : E1601 - E1608
  • [35] Coronary CT Angiography Derived Fractional Flow Reserve: The Game Changer in Noninvasive Testing
    Bjarne Linde Nørgaard
    Jesper Møller Jensen
    Philipp Blanke
    Niels Peter Sand
    Mark Rabbat
    Jonathon Leipsic
    Current Cardiology Reports, 2017, 19
  • [36] VALIDATION AND COMPARISON OF RESTING GRADIENT TO FRACTIONAL FLOW RESERVE FOR ASSESSMENT OF CORONARY ARTERY STENOSIS
    Aoun, J.
    Lahsaei, S.
    Zahm, C.
    Bhat, T.
    Carrozza, J. P.
    CARDIOLOGY, 2018, 140 : 365 - 365
  • [37] Coronary CT Angiography Derived Fractional Flow Reserve: The Game Changer in Noninvasive Testing
    Norgaard, Bjarne Linde
    Jensen, Jesper Moller
    Blanke, Philipp
    Sand, Niels Peter
    Rabbat, Mark
    Leipsic, Jonathon
    CURRENT CARDIOLOGY REPORTS, 2017, 19 (11)
  • [38] Noninvasive numerical simulation of coronary fractional flow reserve based on lattice Boltzmann method
    基于格子玻尔兹曼方法的冠状动脉血流储备分数无创计算研究
    Qiao, Aike (qak@bjut.edu.cn), 2018, West China Hospital, Sichuan Institute of Biomedical Engineering (35):
  • [39] A novel method to simultaneously measure fractional flow reserve and coronary flow reserve
    Gruberg, L
    Mintz, GS
    Weissman, NJ
    Shalman, E
    Barak, C
    Dgani, E
    Pichard, AD
    Berogan, B
    Leon, MB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 92A - 92A
  • [40] Optimal dose of adenosine for coronary flow reserve and fractional flow reserve measurements
    Suh, JW
    Koo, BK
    Kim, HS
    Sohn, DW
    Oh, BH
    Lee, MM
    Park, YB
    Choi, YS
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (8A): : 61A - 61A