Research on individualized distribution approach of coronary resting blood flow for noninvasive calculation of fractional flow reserve

被引:2
|
作者
Zhang, Honghui [1 ]
Wu, Rile [2 ]
Yang, Ning [3 ]
Xie, Jinjie [4 ]
Hou, Yang [5 ]
机构
[1] Inner Mongolia Minzu Univ, Coll Engn, Tongliao 028000, Peoples R China
[2] Tong Liao City Hosp, Dept Neurol, Tongliao 028007, Peoples R China
[3] Harbin Med Univ, Affiliated Hosp 1, Dept Cardiol, Harbin 150001, Peoples R China
[4] Jiahui Int Hosp, Dept Echocardiog, Shanghai 200233, Peoples R China
[5] China Med Univ, Shengjing Hosp, Shenyang 110001, Peoples R China
基金
中国国家自然科学基金;
关键词
Fractional flow reserve; Coronary ultrasound; Individualized; Coronary resting blood flow; Coronary stenosis; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; SCALING LAWS; ANGIOGRAPHY; DESIGN; QUANTIFICATION; IMPACT; ARTERY; MODEL; TREE;
D O I
10.1016/j.cmpb.2023.107704
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objectives: The distribution of coronary resting blood flow is critical for accurately calculating the computed tomography (CT) angiography-derived fractional flow reserve (FFR CT ). However, the diagnostic accuracy of FFR CT calculated by the fixed exponents between two risk factors and coronary resting blood flow, including myocardial mass and diameter of the coronary artery branch, was insufficient compared with invasive fractional flow reserve (FFR). In this study, we proposed the individualized distribution of coronary resting blood flow based on coronary ultrasound blood flow measurement, to improve the diagnostic accuracy of FFR CT calculation. Methods: Five risk factors and an unknown coefficient K were integrated to calculate the individualized distribution of coronary resting blood flow. The K value was fit using the least square method based on coronary ultrasound blood flow measurement results of 30 volunteers. We developed a novel approach for calculating the individualized distribution of coronary resting blood flow and applied it to calculate FFR CT (FFR CTI ). Then, we tested the performance of the individualized distribution approach by comparing it with the approach proposed by Taylor based on coronary ultrasound blood flow measurement results of 13 volunteers. Finally, we tested the diagnostic accuracy of FFR CT calculated by two approaches in invasive FFR of 121 vessels with coronary stenosis. Results: We identified five risk factors and 6.83 x10 -5 for K value, including cardiac output, mean arterial pressure, myocardial mass, coronary artery volume, and diameter of the coronary artery branch, to calculate the individualized distribution of coronary resting blood flow. The mean square error of the individualized distribution approach (0.0088) was significantly less than that of the approach proposed by Taylor (0.0799). The diagnostic accuracy of FFR CTI calculated by the individualized distribution approach (91.74%) was higher than that of the approach proposed by Taylor (FFR CTT ) (82.64%). Conclusions: The individualized distribution approach of coronary resting blood flow can significantly improve the diagnostic accuracy of FFR CT calculation compared with invasive FFR, and support its wide clinical application for diagnosing myocardial ischemia caused by coronary stenosis. & COPY; 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] RETRACTION: Research on individualized distribution approach of coronary resting blood flow for noninvasive calculation of fractional flow reserve
    Zhang, Honghui
    Wu, Rile
    Yang, Ning
    Xie, Jinjie
    Hou, Yang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 255
  • [2] Branch flow distribution approach and its application in the calculation of fractional flow reserve in stenotic coronary artery
    Zhang, Honghui
    Xia, Jun
    Yang, Yinlong
    Yang, Qingqing
    Song, Hongfang
    Xie, Jinjie
    Ma, Yue
    Hou, Yang
    Qiao, Aike
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2021, 18 (05) : 5978 - 5994
  • [3] Physiologically personalized coronary blood flow model to improve the estimation of noninvasive fractional flow reserve
    Liu, Xiujian
    Xu, Chuangye
    Rao, Simin
    Zhang, Ye
    Ghista, Dhanjoo
    Gao, Zhifan
    Yang, Guang
    MEDICAL PHYSICS, 2022, 49 (01) : 583 - 597
  • [4] Noninvasive quantification of myocardial blood flow and coronary flow reserve
    George A. Beller
    Journal of Nuclear Cardiology, 2010, 17 : 544 - 544
  • [5] Noninvasive quantification of myocardial blood flow and coronary flow reserve
    Beller, George A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (04) : 544 - 544
  • [6] A fast algebraic approach for noninvasive prediction of fractional flow reserve in coronary arteries
    Fayssal, Iyad
    Moukalled, Fadl
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (16) : 1761 - 1793
  • [7] Assessment of Fractional Coronary Blood Flow Reserve
    Mironov, V. M.
    Merkulov, E. V.
    Samko, A. N.
    KARDIOLOGIYA, 2012, 52 (08) : 66 - 71
  • [8] Coronary flow reserve and fractional flow reserve
    Ozyol, Ali
    Yilmaz, Mehmet Birhan
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2007, 35 (04): : 253 - 261
  • [9] NONINVASIVE ASSESSMENT OF FRACTIONAL FLOW RESERVE USING MATHEMATICAL MODELING OF CORONARY FLOW
    Gognieva, D. G.
    Syrkin, A. L.
    Vassilevski, Yu V.
    Simakov, S. S.
    Melerzanov, A., V
    Liang, Fuyou
    Lomonosova, A. A.
    Bykova, A. A.
    El Manaa, H. E.
    Kopylov, Ph Yu
    KARDIOLOGIYA, 2018, 58 (12) : 85 - 92
  • [10] REPLY: Importance of Resting Coronary Blood Flow as the Main Determinant of Coronary Flow Reserve
    Kato, Shingo
    Saito, Naka
    Nakachi, Tatsuya
    Fukui, Kazuki
    Iwasawa, Tae
    Taguri, Masataka
    Kosuge, Masami
    Kimura, Kazuo
    Tamura, Kouichi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (22) : 2839 - 2840