Comminuted Olecranon Fractures (Mayo IIB): Is Dynamic Tension Band Wiring Enough?

被引:1
|
作者
Esper, Garrett W. [1 ]
Herbosa, Christopher G. [1 ]
Moses, Michael J. [1 ]
Egol, Kenneth A. [1 ,2 ]
机构
[1] NYU, NYU Langone Hlth, Langone Orthoped Hosp, Dept Orthoped Surg, New York, NY USA
[2] NYU, Grossman Sch Med, Div Orthoped Trauma, Dept Orthoped Surg, 301 E 17th St,14th Floor, New York, NY 10003 USA
关键词
elbow; olecranon; fracture; fixation; impaction; comminuted; tension band wiring; PLATE FIXATION;
D O I
10.1097/BOT.0000000000002474
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives:To compare the efficacy and outcomes of dynamic tension band wiring (TBW) and plate and screw (PS) fixation of comminuted (Mayo Type IIB) olecranon fractures.Design:Retrospective cohort.Setting:Academic medical center.Patients/Participants:Forty-one patients with Mayo type IIB (OTA/AO 2U1C) olecranon fractures were involved in the study.Intervention:Patients with tensile Mayo type IIB olecranon fractures between August 2012 and November 2020 treated by a single surgeon with either TBW or PS fixation were reviewed for demographics, radiographic/surgical details, and clinical/functional outcomes. Descriptive fracture data included proximal olecranon fragment size and the presence of joint impaction at surgery.Main Outcome Measurements:The main outcome measurements were Mayo Elbow Performance Score, elbow range of motion, patient-reported pain, and complications.Results:The mean follow-up was 38 months. Fractures healed for all patients in both groups. No differences in clinical outcomes, functional outcomes, elbow range of motion, or complications were seen between fixation groups. There was no difference in proximal fragment size between the 2 groups. Fractures with articular impaction requiring elevation and grafting demonstrated no difference in clinical or functional outcomes when compared with those that did not have any impaction. However, patients with impacted articular fractures treated with TBW had a higher rate of implant removal (25% vs. 0%, P = 0.05) when compared with those treated with PS.Conclusions:Comminuted Mayo IIB olecranon fractures are amenable to TBW or plate construct, with similar clinical and functional outcomes. The presence of articular impaction is associated with a greater need for implant removal.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [41] Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones
    Dominik Gruszka
    Charlotte Arand
    Julia Greenfield
    Tobias E. Nowak
    Raphael Kuechle
    Sebastian Kuhn
    Pol M. Rommens
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1651 - 1658
  • [42] Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfection
    Schneider, Marco M.
    Nowak, Tobias E.
    Bastian, Leonard
    Katthagen, Jan C.
    Isenberg, Joerg
    Rommens, Pol M.
    Mueller, Lars P.
    Burkhart, Klaus J.
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 847 - 855
  • [43] Olecranon tension plating or olecranon tension band wiring? A comparative biomechanical study
    Gruszka, Dominik
    Arand, Charlotte
    Nowak, Tobias
    Dietz, Sven-Oliver
    Wagner, Daniel
    Rommens, Pol
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (05) : 955 - 960
  • [44] Olecranon tension plating or olecranon tension band wiring? A comparative biomechanical study
    Dominik Gruszka
    Charlotte Arand
    Tobias Nowak
    Sven-Oliver Dietz
    Daniel Wagner
    Pol Rommens
    International Orthopaedics, 2015, 39 : 955 - 960
  • [45] Polyester tension-band wiring of olecranon fractures of elderly people: A simple technique
    Assom, Marco
    Lollino, Nicola
    Caranzano, Francesco
    Rossi, Roberto
    Castoldi, Filippo
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (12): : 1474 - 1476
  • [46] Outcomes of olecranon fractures in adolescents: comparison of tension band wiring and Herbert screw fixations
    Yang, Weiwei
    Zhang, Xintao
    Sun, Dong
    Jin, Shaobin
    Chen, Junfei
    Li, Yang
    FRONTIERS IN PEDIATRICS, 2024, 11
  • [47] TENSION-BAND WIRING OF OLECRANON FRACTURES WITH NONSLIDING PINS - REPORT OF 20 CASES
    LARSEN, E
    JENSEN, CM
    ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (04): : 360 - 362
  • [48] Tension Band Wiring for Olecranon Fractures: Relative Stability of Kirschner Wires in Various Configurations
    Huang, Tsan-Wen
    Wu, Chi-Chuan
    Fan, Kuo-Feng
    Tseng, I-Chuan
    Lee, Po-Cheng
    Chou, Ying-Chao
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (01): : 173 - 176
  • [49] Tension Band Wiring Provides Excellent Patient-Reported Long-Term Results for Both Comminuted and Simple Displaced Olecranon Fractures
    Terstappen, Afra L. E.
    Joosse, Pieter
    van Dijke, Cornelis F.
    Mirck, Boj
    van den Brand, Johan G. H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (07) : E239 - E244
  • [50] REPAIR OF COMMINUTED FRACTURES OF THE PROXIMAL ULNA AND OLECRANON IN YOUNG HORSES USING TENSION BAND PLATING
    COLAHAN, PT
    MEAGHER, DM
    AUSTRALIAN VETERINARY PRACTITIONER, 1980, 10 (02): : 111 - 118