Comminuted Olecranon Fractures (Mayo IIB): Is Dynamic Tension Band Wiring Enough?

被引:1
|
作者
Esper, Garrett W. [1 ]
Herbosa, Christopher G. [1 ]
Moses, Michael J. [1 ]
Egol, Kenneth A. [1 ,2 ]
机构
[1] NYU, NYU Langone Hlth, Langone Orthoped Hosp, Dept Orthoped Surg, New York, NY USA
[2] NYU, Grossman Sch Med, Div Orthoped Trauma, Dept Orthoped Surg, 301 E 17th St,14th Floor, New York, NY 10003 USA
关键词
elbow; olecranon; fracture; fixation; impaction; comminuted; tension band wiring; PLATE FIXATION;
D O I
10.1097/BOT.0000000000002474
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives:To compare the efficacy and outcomes of dynamic tension band wiring (TBW) and plate and screw (PS) fixation of comminuted (Mayo Type IIB) olecranon fractures.Design:Retrospective cohort.Setting:Academic medical center.Patients/Participants:Forty-one patients with Mayo type IIB (OTA/AO 2U1C) olecranon fractures were involved in the study.Intervention:Patients with tensile Mayo type IIB olecranon fractures between August 2012 and November 2020 treated by a single surgeon with either TBW or PS fixation were reviewed for demographics, radiographic/surgical details, and clinical/functional outcomes. Descriptive fracture data included proximal olecranon fragment size and the presence of joint impaction at surgery.Main Outcome Measurements:The main outcome measurements were Mayo Elbow Performance Score, elbow range of motion, patient-reported pain, and complications.Results:The mean follow-up was 38 months. Fractures healed for all patients in both groups. No differences in clinical outcomes, functional outcomes, elbow range of motion, or complications were seen between fixation groups. There was no difference in proximal fragment size between the 2 groups. Fractures with articular impaction requiring elevation and grafting demonstrated no difference in clinical or functional outcomes when compared with those that did not have any impaction. However, patients with impacted articular fractures treated with TBW had a higher rate of implant removal (25% vs. 0%, P = 0.05) when compared with those treated with PS.Conclusions:Comminuted Mayo IIB olecranon fractures are amenable to TBW or plate construct, with similar clinical and functional outcomes. The presence of articular impaction is associated with a greater need for implant removal.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [1] Surgical technique in tension band wiring method for selected comminuted olecranon fractures
    Michio Okamoto
    Jiro Namba
    Kohji Kuriyama
    Satoshi Miyamura
    Hiroyuki Yokoi
    Koji Yamamoto
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 237 - 242
  • [2] Surgical technique in tension band wiring method for selected comminuted olecranon fractures
    Okamoto, Michio
    Namba, Jiro
    Kuriyama, Kohji
    Miyamura, Satoshi
    Yokoi, Hiroyuki
    Yamamoto, Koji
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (02): : 237 - 242
  • [3] Hybrid Tension Band Wiring for Olecranon Fractures
    Kimura, Hiroo
    Morisawa, Yasushi
    Suzuki, Taku
    Iwamoto, Takuji
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (02): : 301 - 305
  • [4] Comparison of tension band wiring and plate fixation in Mayo type 2A olecranon fractures
    Caglar, Ceyhun
    Akcaalan, Serhat
    Ozaslan, Halil Ibrahim
    Yagar, Hilal
    Ugurlu, Mahmut
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (01): : 85 - 92
  • [5] Hook plate fixation and tension band wiring in the treatment of Mayo type II olecranon fractures
    Zhang, Jianyu
    Zhang, Xigong
    Hua, Kehan
    Chen, Chen
    Gong, Maoqi
    Zha, Yejun
    Jiang, Xieyuan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [6] Cancellous Screw with Tension Band Wiring for Fractures of the Olecranon
    Raju, S. M.
    Gaddagi, Rashmi A.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2013, 7 (02) : 339 - 341
  • [7] OSTEOSYNTHESIS BY TENSION BAND WIRING OF DISPLACED FRACTURES OF THE OLECRANON
    DOURSOUNIAN, L
    PREVOT, O
    TOUZARD, RC
    ANNALES DE CHIRURGIE, 1994, 48 (02): : 169 - 177
  • [8] COMPLICATIONS OF TENSION-BAND WIRING OF OLECRANON FRACTURES
    MACKO, D
    SZABO, RM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (09): : 1396 - 1401
  • [9] Patient positioning for tension band wiring of olecranon fractures
    Patel, A.
    Shepherd, K.
    Karthik, K.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2019, 101 (03) : 228 - 229
  • [10] Double Tension Band Wiring for Treatment of Olecranon Fractures
    Kim, Wanlim
    Choi, Sunghun
    Yoon, Jun O.
    Park, Ho Youn
    Kim, Sun Hwa
    Kim, Jin Sam
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (12): : 2438 - 2443