Mid-infrared and near-infrared spectroscopies to classify improper fermentation of pineapple wine

被引:3
|
作者
Kasemsumran, Sumaporn [1 ]
Boondaeng, Antika [2 ]
Ngowsuwan, Kraireuk [1 ]
Jungtheerapanich, Sunee [1 ]
Apiwatanapiwat, Waraporn [2 ]
Janchai, Phornphimon [2 ]
Vaithanomsat, Pilanee [2 ]
机构
[1] Kasetsart Univ, Kasetsart Agr & Agroind Prod Improvement Inst, Lab Nondestruct Qual Evaluat Commod, Bangkok 10900, Thailand
[2] Kasetsart Univ, KAPI, Lab Enzyme & Microbiol, Bangkok 10900, Thailand
关键词
Mid-infrared; Near-infrared; Pineapple wine; Fermentation; Classification; Acetic acid; Acetobacter; TOTAL ANTIOXIDANT CAPACITY; RED WINE; ACETIC-ACID; CHEMOMETRICS; PREDICTION; RICE; IR;
D O I
10.1007/s11696-022-02472-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Improper fermentation of pineapple wine owing to volatile acidity has been associated with excessive proliferation of acetic acid bacteria during fermentation and consequent increased acetic acid concentration. Mid-infrared (MIR) and near-infrared (NIR) spectroscopies were employed to classify improper pineapple wine fermentation. Two clusters of samples possessing within the limit and over-limit acetic acid content were obtained using low-grade pineapples and prepared accordingly. Spectral data were collected for all samples in the 4000-650 cm(-1) region using attenuated total reflection (ATR) with an FT-MIR spectrophotometer and in the 11,536-5800 cm(-1) using sample vials and 11,536-3952 cm(-1) regions using a liquid probe and a liquid cup with an FT-NIR spectrophotometer. The classification models for pineapple wine fermentation based on acetic acid content were constructed using soft independent modeling of class analogy (SIMCA) and partial least squares discriminant analysis (PLSDA). Comparisons of MIR and NIR techniques, classification methods, and spectral pretreatments have been reported. The results demonstrated that MIR spectroscopy coupled with ATR and PLSDA is highly effective for the detection of improper pineapple wine fermentation as a function of acetic acid content. The best classification model was generated using the entire MIR spectra after second derivatives transformation, which provided the highest accuracy, sensitivity, specificity, and precision.
引用
收藏
页码:335 / 349
页数:15
相关论文
共 50 条
  • [21] Routing to mid-infrared microcomb via near-infrared direct pump
    Shi, Lei
    Ming, Xianshun
    Ma, Kai
    Sun, Qibing
    Wang, Leiran
    Zhao, Wei
    Zhang, Wenfu
    OPTICS EXPRESS, 2023, 31 (13) : 20930 - 20940
  • [22] APPLICATION OF PROCRUSTEAN METHODS TO MID-INFRARED AND NEAR-INFRARED SPECTRAL DATA
    VIGNEAU, E
    DEVAUX, MF
    SAFAR, M
    JOURNAL OF CHEMOMETRICS, 1995, 9 (02) : 125 - 135
  • [23] The molecular structure of chloritoid: A mid-infrared and near-infrared spectroscopic study
    Li, Kuo
    Liu, Qinfu
    Cheng, Hongfei
    Deng, Yutao
    Frost, Ray L.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 145 : 604 - 609
  • [24] Rapid Detection of Dichlorvos in Chlorpyrifos by Mid-Infrared and Near-Infrared Spectroscopy
    Gao Xin
    Wang Xin-yu
    Wang Dong
    Hao Xiang Hong
    Min Shun-geng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (11) : 2962 - 2966
  • [25] Comparison of near-infrared and mid-infrared link budgets for optical satellite communication
    Flannigan, Liam
    Xu, Chang-qing
    2022 PHOTONICS NORTH (PN), 2022,
  • [26] Comparison of near-infrared and mid-infrared spectroscopy for the determination of distillation property of kerosene
    Chung, H
    Ku, MS
    Lee, JS
    VIBRATIONAL SPECTROSCOPY, 1999, 20 (02) : 155 - 163
  • [27] Near-infrared frequency comb generation in mid-infrared interband cascade lasers
    Sterczewski, Lukasz A.
    Bagheri, Mahmood
    Frez, Clifford
    Canedy, Chadwick L.
    Vurgaftman, Igor
    Kim, Mijin
    Kim, Chul Soo
    Merritt, Charles D.
    Bewley, William W.
    Meyer, Jerry R.
    OPTICS LETTERS, 2019, 44 (23) : 5828 - 5831
  • [28] THELI: CONVENIENT REDUCTION OF OPTICAL, NEAR-INFRARED, AND MID-INFRARED IMAGING DATA
    Schirmer, M.
    ASTROPHYSICAL JOURNAL SUPPLEMENT SERIES, 2013, 209 (02):
  • [29] Monolithically integrated near-infrared and mid-infrared detector array for spectral imaging
    Bandara, S. V.
    Gunapala, S. D.
    Ting, D. Z.
    Liu, J. K.
    Hill, C. J.
    Mumolo, J. M.
    Keo, S.
    INFRARED PHYSICS & TECHNOLOGY, 2007, 50 (2-3) : 211 - 216
  • [30] MXene Photonic Devices for Near-Infrared to Mid-Infrared Ultrashort Pulse Generation
    Wang, Zhenhong
    Li, Hongbo
    Luo, Mulin
    Chen, Tenghui
    Xia, Xuefeng
    Chen, Hualong
    Ma, Chunyang
    Guo, Jia
    He, Zhenwu
    Song, Yufeng
    Liu, Jun
    Jiang, Xiantao
    Zhang, Han
    ACS APPLIED NANO MATERIALS, 2020, 3 (04): : 3513 - 3522