Quantitative pulsatility measurements using 3D dynamic ultrasound localization microscopy

被引:2
|
作者
Bourquin, Chloe [1 ]
Poree, Jonathan [1 ]
Rauby, Brice [1 ]
Perrot, Vincent [1 ]
Ghigo, Nin [1 ]
Belgharbi, Hatim [1 ,2 ]
Belanger, Samuel [3 ]
Ramos-Palacios, Gerardo [4 ]
Cortes, Nelson [5 ]
Ladret, Hugo [5 ,6 ,7 ]
Ikan, Lamyae [5 ]
Casanova, Christian [5 ]
Lesage, Frederic [8 ,9 ]
Provost, Jean [1 ,9 ]
机构
[1] Dept Engn Phys, Polytech Montreal, Montreal, PQ H3T 1J4, Canada
[2] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[3] Labeo Technol Inc, Montreal, PQ H3V 1A2, Canada
[4] McGill Univ, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
[5] Univ Montreal, Sch Optometry, Montreal, PQ H3T 1P1, Canada
[6] CNRS, Inst Neurosci Timone, UMR 7289, F-13005 Marseille, France
[7] Aix Marseille Univ, F-13005 Marseille, France
[8] Dept Elect Engn, Polytech Montreal, Montreal, PQ H3T 1J4, Canada
[9] Montreal Heart Inst, Montreal, PQ H1T 1C8, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 04期
基金
加拿大健康研究院; 加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
dynamic ultrasound localization microscopy; 3D brain imaging; pulsatility index; Kalman filtering; BLOOD-FLOW CHANGES; IN-VIVO; DOPPLER; SUPERRESOLUTION; VELOCITY; ATHEROSCLEROSIS; DECLINE; DISEASE; MICE;
D O I
10.1088/1361-6560/ad1b68
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A rise in blood flow velocity variations (i.e. pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with large penetration depth and high spatiotemporal resolution. The development of dynamic ultrasound localization microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures only 2D-projected and hence biased velocities . Herein, we present 3D DULM: using a single ultrasound scanner at high frame rate (1000-2000 Hz), this method can produce dynamic maps of microbubbles flowing in the bloodstream and extract quantitative pulsatility measurements in the cat brain with craniotomy and in the mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, which could be mapped with ultrasound down to a few tens of micrometers for the first time. We also performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the brain, which could be linked to early signs of neurodegenerative diseases.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [31] Quantitative 3D ultrasound imaging using an automated image tracking technique
    Hossack, JA
    Sumanaweera, TS
    Napel, S
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1593 - 1596
  • [32] Fringe projection based quantitative 3D microscopy
    Li, Ameng
    Peng, Xiang
    Yin, Yongkai
    Liu, Xiaoli
    Zhao, Qinping
    Koerner, Klaus
    Osten, Wolfgang
    OPTIK, 2013, 124 (21): : 5052 - 5056
  • [33] Localization and circumnavigation of an unknown target using distance measurements in 3D space
    Yu, Ce
    Shi, Yingjing
    Li, Rui
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2024,
  • [34] Fast and quantitative 2D and 3D orientation mapping using Raman microscopy
    Oleksii Ilchenko
    Yuriy Pilgun
    Andrii Kutsyk
    Florian Bachmann
    Roman Slipets
    Matteo Todeschini
    Peter Ouma Okeyo
    Henning Friis Poulsen
    Anja Boisen
    Nature Communications, 10
  • [35] Fast and quantitative 2D and 3D orientation mapping using Raman microscopy
    Ilchenko, Oleksii
    Pilgun, Yuriy
    Kutsyk, Andrii
    Bachmann, Florian
    Slipets, Roman
    Todeschini, Matteo
    Okeyo, Peter Ouma
    Poulsen, Henning Friis
    Boisen, Anja
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [36] Validation of volume measurements in esophageal pseudotumors using 3D endoluminal ultrasound
    Liu, JB
    Miller, LS
    Chung, CY
    Overton, DA
    Sheera, M
    Forsberg, F
    Goldberg, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (05): : 735 - 741
  • [37] Quantification of carotid plaque volume measurements using 3D ultrasound imaging
    Landry, A
    Spence, JD
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06): : 751 - 762
  • [38] Quantitative dynamic cellular imaging based on 3D unwrapped optically computed phase microscopy
    Liu, Xuan
    Liu, Yuwei
    Wan, Zhaoxiong
    Gunasekar, Arun Kumar
    Zhang, Yuanwei
    APPLIED OPTICS, 2022, 61 (27) : 7999 - 8005
  • [39] Comparison of quantitative 3D myocardial wall measurements using MRI and SPECT
    Prasad, Mithun
    Tamarappoo, Balaji
    Ramesh, Amit
    Kavanagh, Paul
    Gerlach, James
    Thomson, Louise
    Friedman, John
    Berman, Daniel
    Germano, Guido
    Slomka, Piotr
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [40] PROBE LOCALIZATION USING STRUCTURE FROM MOTION FOR 3D ULTRASOUND IMAGE RECONSTRUCTION
    Ito, Shuya
    Ito, Koichi
    Aoki, Takafumi
    Ohmiya, Jun
    Kondo, Satoshi
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 68 - 71