CT-guided Transgluteal Prostate Fiducial Marker Insertion for Localized Radiation Therapy

被引:2
|
作者
Khanmohammadi, Shaghayegh [1 ,2 ]
Golzarian, Jafar [3 ]
Akhlaghpoor, Shahram [4 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Immunodeficiencies, Childrens Med Ctr, Tehran 14194, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Populat Sci Inst, Noncommunicable Dis Res Ctr, Tehran, Iran
[3] Univ Minnesota, Dept Radiol Vasc & Intervent Radiol, Minneapolis, MN USA
[4] Pardis Noor Med Imaging Ctr, Dept Radiol, 5, 25th St, Saadat abad St, Tehran, Iran
关键词
Radiotherapy; Fiducial marker; Prostate cancer; Interventional radiology; EXTERNAL-BEAM RADIOTHERAPY; RECTAL ACCESS; GOLD MARKERS; BIOPSY; TRANSPERINEAL; COMPLICATIONS; IMPLANTATION; EXPERIENCE;
D O I
10.1007/s00270-023-03539-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo Evaluate the safety and technical success of transgluteal CT-guided fiducial marker implantation into the prostate as an alternative method to transperineal and transrectal approaches.Material and MethodsWe retrospectively identified all patients who had undergone CT-guided transgluteal fiducial marker insertion between 2020 and 2022. Four patients with confirmed prostate cancer were identified. One radiologist performed all procedures via a bilateral transgluteal approach under the guidance of real-time CT-fluoroscopy. Twenty cm long pre-waxed 18G guiding needles, preloaded with smooth gold fiducial markers, were used to implant markers. Technical success was defined as the successful placement of the fiducial markers into the planned positions.ResultsThe mean age of patients was 70 years. The mean procedure time was 19.25 (SD: 6.75) min, and the mean total dose length product (DLP) was 801.75 (SD: 291.17) mGycm, which is compatible with the 12 mSv estimated effective dose. All procedures were technically successful (100%). All patients tolerated the procedure and did not require any analgesia for pain, and there were no requests to stop or pause the procedure. Only one patient reported hematuria one day after the procedure, which required no treatment.ConclusionTransgluteal CT-guided fiducial marker implantation into the prostate is an alternative method to transperineal and transrectal approaches. In this technique, the risk of septic complications is minor, and general anesthesia is not required. Thus, transgluteal CT-guided marker insertion is a feasible and well-tolerated method for image-guided radiation therapy (IGRT) in patients with prostate cancer.
引用
收藏
页码:1409 / 1413
页数:5
相关论文
共 50 条
  • [21] Fiducial marker implantation in prostate radiation therapy: Complication rates and technique
    Fawaz, Z. S.
    Yassa, M.
    Nguyen, D. H.
    Vavassis, P.
    CANCER RADIOTHERAPIE, 2014, 18 (08): : 736 - 739
  • [22] The risk of urosepsis in patients undergoing fiducial marker placement for image guided radiation therapy (IGRT) of prostate cancer
    Obedian, E.
    Kapoor, D. A.
    Olsson, C. A.
    Zimberg, S. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S324 - S325
  • [23] The Risk of Urosepsis in Patients Undergoing Fiducial Marker Placement for Image Guided Radiation Therapy (IGRT) of Prostate Cancer
    Obedian, E.
    Olsson, C.
    Schumer, M.
    Lieberman, E.
    Kapoor, D.
    Zimberg, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S383 - S383
  • [24] Computed Tomography-Guided Prostate Sampling and Fiducial Marker Insertion in Patients With Absent Rectums
    Chau, Matthew
    Saluja, Manmeet
    Anderson, James
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (01) : 72 - 76
  • [25] Lipiodol as a Fiducial Marker for Image-Guided Radiation Therapy for Bladder Cancer
    Freilich, Jessica M.
    Spiess, Philippe E.
    Biagioli, Matthew C.
    Fernandez, Daniel C.
    Shi, Ellen J.
    Hunt, Dylan C.
    Gupta, Shilpa
    Wilder, Richard B.
    INTERNATIONAL BRAZ J UROL, 2014, 40 (02): : 190 - 197
  • [26] Planting the seeds of success: CT-guided gold seed fiducial marker placement to guide robotic radiosurgery
    Patel, Aashish
    Khalsa, Bhavraj
    Lord, Bryce
    Sandrasegaran, Kumar
    Lall, Chandana
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (02) : 207 - 211
  • [27] Robot-to-image Registration with Geometric Marker for CT-guided Robotic Needle Insertion
    Ikeda, Iori
    Sekine, Kai
    Tsumura, Ryosuke
    Iwata, Hiroyasu
    2021 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA 2021), 2021, : 7130 - 7136
  • [28] CT-Guided Fiducial Marker Implantation with Ultra-fine 25-Gauge Needle Prior to Proton Therapy for Liver Malignancies
    Horibe, Akihiro
    Ohta, Kengo
    Shoji, Jumpei
    Hatano, Mototaka
    Shiotani, Yujiro
    Anan, Kumiko
    Nomura, Kento
    Iwata, Hiromitsu
    Ogino, Hiroyuki
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 47 (09) : 1287 - 1293
  • [29] CT-guided pain therapy
    Proske, M
    Steinbrich, W
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1996, 126 (29) : 1270 - 1273
  • [30] Radiation exposure in CT-guided interventions
    Kloeckner, Roman
    dos Santos, Daniel Pinto
    Schneider, Jens
    Kara, Levent
    Dueber, Christoph
    Pitton, Michael B.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2253 - 2257