Night-to-Night Variability of Polysomnography-Derived Physiologic Endotypic Traits in Patients With Moderate to Severe OSA

被引:23
|
作者
Strassberger, Christian [1 ]
Hedner, Jan [1 ,2 ]
Sands, Scott A. [3 ]
Tolbert, Thomas M. [4 ,5 ]
Taranto-Montemurro, Luigi [3 ]
Marciniak, Albert [1 ]
Zou, Ding [1 ]
Grote, Ludger [1 ,2 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Ctr Sleep & Vigilance Disorders, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Ctr Sleep Med, Dept Resp Med, Gothenburg, Sweden
[3] Icahn Sch Med Mt Sinai, Div Pulm Crit Care & Sleep Med, New York, NY USA
[4] Brigham & Womens Hosp, Div Sleep & Circadian Disorders, Boston, MA USA
[5] Harvard Med Sch, Boston, MA USA
基金
美国国家卫生研究院;
关键词
arousal threshold; collapsibility; endotypes; loop gain; muscle compensation; phenotypes; polysomnography; precision medicine; reliability; sleep-disordered breathing; OBSTRUCTIVE SLEEP-APNEA; HYPOPNEA INDEX; LOOP GAIN; POSITION;
D O I
10.1016/j.chest.2022.12.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Emerging data suggest that determination of physiologic endotypic traits (eg, loop gain) may enable precision medicine in OSA.RESEARCH QUESTION: Does a single-night assessment of polysomnography-derived endotypic traits provide reliable estimates in moderate to severe OSA?STUDY DESIGN AND METHODS: Two consecutive in-lab polysomnography tests from a clinical trial (n = 67; male, 69%; mean +/- SD age, 61 +/- 10 years; apnea-hypopnea index [AHI] 53 +/- 22 events/h) were used for the reliability analysis. Endotypic traits, reflecting upper airway collapsibility (ventilation at eupneic drive [Vpassive]), upper airway dilator muscle tone (ventilation at the arousal threshold [Vactive]), loop gain (stability of ventilatory control, LG1), and arousal threshold (ArTh) were determined. Reliability was expressed as an intraclass correlation coefficient (ICC). Minimal detectable differences (MDDs) were computed to pro-vide an estimate of maximum spontaneous variability. Further assessment across four repeated polysomnography tests was performed in a subcohort (n = 22). RESULTS: Reliability of endotypic traits between the two consecutive nights was moderate to good (ICC: Vpassive = 0.82, Vactive = 0.76, LG1 = 0.72, ArTh = 0.83). Variability in AHI, but not in body position or in sleep stages, was associated with fluctuations in Vpassive and Vactive (r = -0.49 and r = -0.41, respectively; P < .001 for both). MDDs for single-night assessments were: Vpassive = 22, Vactive = 34, LG1 = 0.17, and ArTh = 21. Multiple assessments (mean of two nights, n = 22) further reduced MDDs by approximately 20% to 30%. INTERPRETATION: Endotypic trait analysis using a single standard polysomnography shows acceptable reliability and reproducibility in patients with moderate to severe OSA. The re-ported MDDs of endotypic traits may facilitate the quantification of relevant changes and may guide future evaluation of interventions in OSA. CHEST 2023; 163(5):1266-1278
引用
收藏
页码:1266 / 1278
页数:13
相关论文
共 30 条
  • [11] Night-to-night variability in periodic leg movements in patients with restless legs syndrome
    Sforza, E
    Rubio, JH
    SLEEP, 2005, 28 : A268 - A269
  • [12] Low night-to-night variability of sleep disordered breathing in patients with stable congestive heart failure
    Olaf Oldenburg
    Barbara Lamp
    Klaus Freivogel
    Thomas Bitter
    Christoph Langer
    Dieter Horstkotte
    Clinical Research in Cardiology, 2008, 97 : 836 - 842
  • [13] Low night-to-night variability of sleep disordered breathing in patients with stable congestive heart failure
    Oldenburg, Olaf
    Lamp, Barbara
    Freivogel, Klaus
    Bitter, Thomas
    Langer, Christoph
    Horstkotte, Dieter
    CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (11) : 836 - 842
  • [14] Night-to-Night Variability of Muscle Tone, Movements, and Vocalizations in Patients with REM Sleep Behavior Disorder
    Cygan, Fanny
    Oudiette, Delphine
    Leclair-Visonneau, Laurene
    Leu-Semenescu, Smaranda
    Arnulf, Isabelle
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2010, 6 (06): : 551 - 555
  • [15] NIGHT-TO-NIGHT VARIABILITY OF SLEEP QUALITY USING ODDS RATIO PRODUCT: AN ASSESSMENT OF 14-31 NIGHTS OF IN-HOME POLYSOMNOGRAPHY
    Bender, A.
    Lambing, K.
    Ariyibi, B.
    Nematollahi, N.
    Gerardy, B.
    Younes, M.
    SLEEP MEDICINE, 2022, 100 : S85 - S85
  • [16] Short-term stability and night-to-night variability of sleep parameters in nightmares comorbid with chronic insomnia Disorder across multiple nights of polysomnography
    Paquet, Caitlin
    Lenker, Kristina P.
    Calhoun, Susan L.
    Bixler, Edward O.
    Vgontzas, Alexandros N.
    Fernandez-Mendoza, Julio
    SLEEP, 2024, 47 (04)
  • [17] PHENOTYPING OF PATIENTS WITH MODERATE TO SEVERE OSA ON POLYSOMNOGRAPHY AFTER NEGATIVE HOME SLEEP APNEA TESTING
    Sarfraz, Sarah
    McCullough, Lindsay
    Arantes, Henry
    Lastra, Alejandra
    SLEEP, 2021, 44 : A187 - A187
  • [18] Long-term variability and reliability of physiological endotypic traits derived in clinical routine in patients with obstructive sleep apnea
    Strassberger, C.
    Zou, D.
    Marciniak, A.
    Hedner, J.
    Grote, L.
    JOURNAL OF SLEEP RESEARCH, 2022, 31
  • [19] Efficacy of split night CPAP titration in moderate and severe obstructive sleep apnea syndrome patients
    Farghaly, Shereen
    Shaaban, Lamiaa H.
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2016, 65 (01): : 251 - 257
  • [20] Waiting for in-Lab Polysomnography May Unnecessarily Prolong Treatment Start in Patients with Moderate or Severe OSA at Home Sleep Apnea Testing
    Pordzik, Johannes
    Seifen, Christopher
    Ludwig, Katharina
    Ruckes, Christian
    Huppertz, Tilman
    Matthias, Christoph
    Gouver, Haralampos
    NATURE AND SCIENCE OF SLEEP, 2024, 16 : 1881 - 1889