Night-to-Night Variability of Polysomnography-Derived Physiologic Endotypic Traits in Patients With Moderate to Severe OSA

被引:23
|
作者
Strassberger, Christian [1 ]
Hedner, Jan [1 ,2 ]
Sands, Scott A. [3 ]
Tolbert, Thomas M. [4 ,5 ]
Taranto-Montemurro, Luigi [3 ]
Marciniak, Albert [1 ]
Zou, Ding [1 ]
Grote, Ludger [1 ,2 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Ctr Sleep & Vigilance Disorders, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Ctr Sleep Med, Dept Resp Med, Gothenburg, Sweden
[3] Icahn Sch Med Mt Sinai, Div Pulm Crit Care & Sleep Med, New York, NY USA
[4] Brigham & Womens Hosp, Div Sleep & Circadian Disorders, Boston, MA USA
[5] Harvard Med Sch, Boston, MA USA
基金
美国国家卫生研究院;
关键词
arousal threshold; collapsibility; endotypes; loop gain; muscle compensation; phenotypes; polysomnography; precision medicine; reliability; sleep-disordered breathing; OBSTRUCTIVE SLEEP-APNEA; HYPOPNEA INDEX; LOOP GAIN; POSITION;
D O I
10.1016/j.chest.2022.12.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Emerging data suggest that determination of physiologic endotypic traits (eg, loop gain) may enable precision medicine in OSA.RESEARCH QUESTION: Does a single-night assessment of polysomnography-derived endotypic traits provide reliable estimates in moderate to severe OSA?STUDY DESIGN AND METHODS: Two consecutive in-lab polysomnography tests from a clinical trial (n = 67; male, 69%; mean +/- SD age, 61 +/- 10 years; apnea-hypopnea index [AHI] 53 +/- 22 events/h) were used for the reliability analysis. Endotypic traits, reflecting upper airway collapsibility (ventilation at eupneic drive [Vpassive]), upper airway dilator muscle tone (ventilation at the arousal threshold [Vactive]), loop gain (stability of ventilatory control, LG1), and arousal threshold (ArTh) were determined. Reliability was expressed as an intraclass correlation coefficient (ICC). Minimal detectable differences (MDDs) were computed to pro-vide an estimate of maximum spontaneous variability. Further assessment across four repeated polysomnography tests was performed in a subcohort (n = 22). RESULTS: Reliability of endotypic traits between the two consecutive nights was moderate to good (ICC: Vpassive = 0.82, Vactive = 0.76, LG1 = 0.72, ArTh = 0.83). Variability in AHI, but not in body position or in sleep stages, was associated with fluctuations in Vpassive and Vactive (r = -0.49 and r = -0.41, respectively; P < .001 for both). MDDs for single-night assessments were: Vpassive = 22, Vactive = 34, LG1 = 0.17, and ArTh = 21. Multiple assessments (mean of two nights, n = 22) further reduced MDDs by approximately 20% to 30%. INTERPRETATION: Endotypic trait analysis using a single standard polysomnography shows acceptable reliability and reproducibility in patients with moderate to severe OSA. The re-ported MDDs of endotypic traits may facilitate the quantification of relevant changes and may guide future evaluation of interventions in OSA. CHEST 2023; 163(5):1266-1278
引用
收藏
页码:1266 / 1278
页数:13
相关论文
共 30 条
  • [1] NIGHT-TO-NIGHT VARIABILITY OF AUTOMATICALLY DERIVED PHYSIOLOGICAL ENDOTYPIC TRAITS IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA
    Strassberger, C.
    Zou, D.
    Marciniak, A.
    Hedner, J.
    Grote, L.
    SLEEP MEDICINE, 2022, 100 : S260 - S260
  • [2] The impact of night-to-night variability as a trait on polysomnography
    Unbehaun, T.
    Feige, B.
    Spiegelhalder, K.
    Nissen, C.
    Hirscher, V.
    Riemann, D.
    JOURNAL OF SLEEP RESEARCH, 2012, 21 : 216 - 216
  • [3] Night-to-night variability in home polysomnography parameters
    Tobback, N.
    Andries, D.
    Tafti, M.
    Haba-Rubio, J.
    Heinzer, R.
    JOURNAL OF SLEEP RESEARCH, 2012, 21 : 204 - 205
  • [4] Evaluation of night-to-night variability of sleep apnea in home polysomnography
    Rohling, L. C.
    Tijdens, R.
    van Kralingen, K. W.
    JOURNAL OF SLEEP RESEARCH, 2018, 27
  • [5] Night-to-night variability of polysomnography in children with suspected obstructive sleep apnea
    Katz, ES
    Greene, MG
    Carson, KA
    Galster, P
    Loughlin, GM
    Carroll, J
    Marcus, CL
    JOURNAL OF PEDIATRICS, 2002, 140 (05): : 589 - 594
  • [6] Is there a night-to-night variability in sleep structure in patients with chronic insomnia?
    Cervena, K.
    Karunajeewa, A. S.
    Sforza, E.
    JOURNAL OF SLEEP RESEARCH, 2006, 15 : 38 - 38
  • [7] HOME AUTOMATED OSA QUANTIFICATION OF NIGHT-TO-NIGHT SHORT TERM VARIABILITY: ANALYSIS OF THE ASSOCIATED CONDITIONS
    Pepin, Jean-Louis
    Martinot, Jean-Benoit
    Bailly, Sebastien
    Tamisier, Renaud
    Le-Dong, Nhat-Nam
    SLEEP, 2023, 46 : A221 - A221
  • [8] First-night effect and night-to-night variability in patients with suspected OSAS
    Anderer, P.
    Moreau, A.
    Ross, M.
    Cerny, A.
    Loeffler, S.
    Thusoo, S.
    JOURNAL OF SLEEP RESEARCH, 2014, 23 : 203 - 204
  • [9] Assessment of polysomnography: first-night effect and night-to-night variability: relationships to diagnosis and intra-individual differences
    Newell, J.
    Mairesse, O.
    Verbanck, P.
    Neu, D.
    JOURNAL OF SLEEP RESEARCH, 2012, 21 : 216 - 216
  • [10] Night-to-night variability in periodic leg movements in patients with restless legs syndrome
    Sforza, E
    Haba-Rubio, J
    SLEEP MEDICINE, 2005, 6 (03) : 259 - 267